Extra Inline Equipment Components - Circular Air Intake Hood
- Last UpdatedJan 19, 2026
- 2 minute read
The task of creating an HVAC Component is initiated from the HVAC Window.
-
Select Extra Plant Equipment in the Categories dropdown list.
-
Select Circular Air Intake Hood in the Available Type dropdown list to display the Air Intake Hood window:

The Air Intake Hood window default is a standard stock size, but can be changed by using one of the following methods:
-
Standard Stock Sizes
-
Non-Standard Stock Sizes (Special)
-
Standard Stock Sizes
-
In the Name(Ref) field, enter the name of the HVAC component.
Note: The fields will be pre-populated with default dimensions. These dimensions are governed by the details defined in the HVAC Catalog.
-
To choose from the standard stock sizes available from the HVAC Catalog, in the Stock Size dropdown list, select the required dimension for the HVAC component.
Non-Standard Stock Sizes (Special)
-
To choose to use a non-standard stock piece of HVAC, from the Stock Sizes dropdown list, select Special.
You are required to input the following dimensions:
-
Name(Ref)
-
Duct Diameter
-
Overall Diameter
-
Overall Height
-
Cowl Height
-
-
To visualize how the dimensions equate to the actual piece of HVAC, select Picture to display a detailed drawing for Extra Plant Equipment Catalog Element - Circular Air Intake Hood.
Note: The fields will be pre-populated with default dimensions. These dimensions are governed by the details defined in the .
-
Specify a type of joint to use for the Arrjoint (Arrive Joint). For a detailed description, see Create / Modify HVAC Components.
-
In the Connect list, select Connect or Unchanged:
-
Select Connect (default when Create is selected) - connects the piece of HVAC to the previous one.
-
Select Unchanged (default when Modify is selected) - positions the component at the co-ordinates 0.00.
Note: Unchanged is usually used, when Modify is selected, it does not connect the component but positions it at 0.00, in effect in a floating position.
-
-
Select Defaults to reset all the fields back to when the Air Intake Hood window was opened.
-
Select Fit to orientate the Air Intake Hood to automatically match the outlet (p-leave) of the previous piece of HVAC to the inlet (p-arrive) of the next piece.
-
Select OK to create the Air Intake Hood component and close the Air Intake Hood Window. You will be returned to the HVAC Window.
-