The program uses some specific control variables. If used, it shall be added to a file with name matplate.ip placed on the directory associated with the logical SB_SHIP.

The ips of the program are listed below.

STEELDENSITY, <density>,

If this ip is given, the calculations are made using the real <density> as the value of steel density in tons/m3. Otherwise the value 7.86 is used.

EXCESS, <excess>,

By this ip the addition of excess material can be controlled. Plane plates will be extended by <excess> millimeters at each side of their length and width. Default value is 15 mm if this ip is not given.

Note: This ip is valid for plane plates only! For developed plates, the excess may be controlled by the plate development program.