Format 6
- Last UpdatedJan 30, 2023
- 1 minute read
Format 6 (used with controller KOIKE and variant V1 and controller EIA and variant V11) of the file is as follows. The file specifies the burning speed (F code),
Bevel (S code) and Kerf register number (D code) for each bevel angle in blocks for each plate thickness, side (1 = SB for surface bevel, 2 = BB for bottom bevel).
The PLASMA data file contains separate blocks for this side and other side.
* SB06 ************* GAS **************
06 1 2
0 500 0.0 (S0000) 0.80 (D 08)
1 0 0.0 (S0000) 0.80 (D 08)
* SB 09 *********** PLASMA ***************
09 1 46
0 4262 -3.2 (S2032) 1.1 (D 13)
1 4264 -2.1 (S2021) 1.5 (D 12)
2 4265 -0.9 (S2005) 1.3 (D 11)
* BB 09 *********** PLASMA ***************
09 2 30
1 4258 -4.2 (S2042) 1.8 (D 13)
2 4253 -5.6 (S2056) 1.8 (D 13)
3 4241 -6.9 (S2069) 1.9 (D 14)