Set the Output Units

  • Last UpdatedJan 05, 2026
  • 2 minute read

Keywords:

OUTPUT_UNITS

Description:

This command controls how ExPLANT-I writes units to the attribute file. It does not affect unit handling within the DGN file. The default is use Marine internal units (typically millimeters).

Examples:

OUTPUT_UNITS RAW

Use Marine internal units. This should not be combined with any other OUTPUT_UNITS command

OUTPUT_UNITS MM DECIMAL 3

When writing a value in millimeters, use three decimal places.

OUTPUT_UNITS INCH DECIMAL 2

When writing a value in inches, use two decimal places.

OUTPUT_UNITS FINCH FRACTION 32

When writing a value in feet and inches, use fractions as small as 1/32 of an inch.

OUTPUT_UNITS BORE NOMINAL MM

DECIMAL 3

When writing a value which is in bore units, output the nominal bore in millimeters to three decimal places.

OUTPUT_UNITS BORE ACTUAL INCH

When writing a value which is in bore units, output the actual bore in inches to the ordinary inch precision.

OUTPUT_UNITS DISTANCE FINCH

FRACTION 64

When writing a value in distance units, output in feet and inches to 1/64 of an inch.

Here are some examples of sets of OUTPUT_UNIT commands:

  • If you want bore and distance values to be reported in millimeters, using the nominal bore to one decimal place, all other dimensions to three decimal places you should include:

    OUTPUT_UNITS MM DECIMAL 3

    OUTPUT_UNITS DISTANCE MM

    OUTPUT_UNITS BORE NOMINAL MM DECIMAL 1

  • If you want distances to be in feet, inches and eighths of an inch, actual bores in inches to three decimal places, and any other inch dimensions to one decimal place you should include:

    OUTPUT_UNITS DISTANCE FINCH FRACTION 8

    OUTPUT_UNITS BORE ACTUAL INCH DECIMAL 3

    OUTPUT_UNITS INCH DECIMAL 1

TitleResults for “How to create a CRG?”Also Available in