Hull and Outfitting

Re-selecting the New Default Component

  • Last UpdatedNov 17, 2025
  • 1 minute read

Keywords:

RESELECT

Description:

The RESELECT command chooses a new Component and its Leave Tube from the Branch Specification. The default Selection parameters are obtained from the current element’s surroundings (in the same way as for SELECT). If any further Selection parameters are needed, they are obtained from the old Component Specification entries. The need to respecify is therefore reduced.

Examples:

RESEL

The current element and Leave Tube will be Selected from the new default choice(s). Any parameters required that are not obtainable from defaults will be derived from the old Specification Component.

Note: This command only operates on Components that have already been Selected.

Command Syntax:

>-- RESElect -->

Querying:

                            .-----<-----.
                           /            |
>-- Query SPECification --*-- <qspci> --+-->

<qspci> is explained in the section on Standard Syntax Graphs in the Design Reference Manual.

>-- Query --+-- SPRef ---.
            |            |
            ‘-- TUbe ----+-->