Rectangular Components - Radiused Splitter
- Last UpdatedJan 13, 2026
- 2 minute read
The task of creating an HVAC Component is initiated from the HVAC Window.
-
Select Rectangular in the Categories dropdown list and then Radiused Splitter in the Available Type dropdown list to display the Radiused Splitter window:

You are required to input dimensions for the new HVAC Component:
-
Duct width AA
-
Duct depth AB
-
Angle
-
Bend Inside Radius
-
Bend A Extension
-
Bend L Extension
-
Splitter Radius
-
Splitter Aext
-
Splitter Lext
-
-
To visualize how the dimensions equate to the actual piece of HVAC select Picture to display a detailed drawing for Rectangular Components Catalog Element - Radius Splitter.
Note: The fields will be pre-populated dimensions. These dimensions are governed by the detailed defined in the HVAC Catalog.
-
Select Transpose width/depth to exchange Duct width AA dimension with Duct depth AB dimension.
-
In the Connect list, select Connect or Unchanged:
-
Select Connect (default when Create is selected) - connects the piece of HVAC to the previous one.
-
Select Unchanged (default when Modify is selected) - positions the component at the co-ordinates 0.00.
-
-
Select Defaults to clear all the dimension currently in the window and set them to the dimension when the window was first opened.
-
Select Fit to orientate the piece of HVAC to automatically match the outlet (p-leave) of the previous piece of HVAC to the inlet (p-arrive) of the next piece.
-
Select OK to create the Rectangular Radiused Splitter element in the Design database and close the Radiused Splitter Window. You will be returned to the HVAC Window.
-
Select Cancel to close the Radiused Splitter window and discard any dimension input in the fields.