Inline Equipment Components - Rectangular Attenuated Bend r

Inline Equipment Components - Rectangular Attenuated Bend r

  • Last UpdatedJan 27, 2026
  • 2 minute read

The task of creating an HVAC Component is initiated from the HVAC Window.

  1. Select Inline Plant Equipment in the Categories dropdown list.

  2. Select RECTANGULAR Attenuated Bend r in the Available Type dropdown list to display the Attenuated Bend window:

    You are is required to input the following dimensions:

    • Name(Ref)

    • Duct width AA

    • Duct depth AB

    • Duct width LA

    • Arrive Throat

    • Leave Throat

    • Inside Radius

    • Back Radius

    • Arri Back Fillet

    • PL to Back Fillet

    • Arri Thrt Fillet

    • PL to Thrt Fillet

  3. To visualize how the dimensions equate to the actual piece of HVAC, select Picture to display a detailed drawing for Inline Plant Equipment Catalog - Rectangular Attenuated Bend.

    Note: The fields will be pre-populated with default dimensions. These dimensions are governed by the details defined in the HVAC Catalog.

  4. Select Transpose width/depth to exchange Duct Width AA dimension with the Duct Width AB dimension.

  5. Specify a type of joint to use for the Arrjoint (Arrive Joint) and Leajoint (Leave joint). For a detailed description, see Create / Modify HVAC Components.

  6. After selecting the type of joint to use for the Arrjoint and Leajoint, enter the Leave Direction.

  7. In the Leave Direction specify the axis that should be used. Valid axes are E (East), N (North), U (Up), -E (negative East), -N (negative North) or -U (Negative Up). X, Y, Z, -X, -Y or -Z.

  8. In the Connect list, select Connect or Unchanged:

    • Select Connect (default when Create is selected) - connects the piece of HVAC to the previous one.

    • Select Unchanged (default when Modify is selected) - positions the piece of HVAC at the co-ordinates 0.00.

    Note: Unchanged is usually used, when Modify is selected, it does not connect the piece of HVAC but positions it at 0.00, in effect in a floating position.

  9. Select Defaults to reset all the fields back to when the Attenuated Bend window was opened.

  10. Select Fit to orientate the Attenuated Bend to automatically match the outlet (p-leave) of the previous piece of HVAC to the inlet (p-arrive) of the next piece.

  11. Select OK to create the Attenuated Bend component and close the Attenuated Bend Window. You will be returned to the HVAC Window.

  12. Select Cancel to discard all the field changes and close the Attenuated Bend window.