Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

Hull and Outfitting

Example of Detailing Using Isodraft Commands

  • Last UpdatedJan 07, 2026
  • 1 minute read

Assume that a Project DB includes the MDB /TESTSITE which, in turn, has access to an Design database named PIPING/AREA-A and a correctly set up Catalogue DB. This has a structure as shown below.

The following sequence of commands could be used to create isometric drawings, in the default format, of the two pipes /PIPE-Y and /PIPE-Z. The example assumes that data consistency checking in the Design database finds no faults.

/TESTSITE

Specify MDB

Design 

Enter Design, which has data consistency checking facilities

CHECK /PIPE-Y /PIPE-Z

Check data consistency of pipes

A data consistency report is generated: a report of no errors is assumed

Isodraft

Enter Isodraft module

FILE /ISOFILE SINGLE

Specify Isodraft output device

The two pipe drawings to be created will be sent to separate plot files, identified as /ISOFILE001 and /ISOFILE002

MESSAGEFILENAME /ISOMESS

Specify filename for messages

QUERY OPTIONS

Check the current settings of all Isodraft plotting options

ADD /ZONE-1

REMOVE /PIPE-X

Set up list of pipes to be drawn by Isodraft

DETAIL ALL

Draw isometrics of required pipes

The last three commands could be replaced by:

DETAIL /PIPE-Y /PIPE-Z