Clash Checking the CE (Current Element)
- Last UpdatedNov 14, 2025
- 1 minute read
This procedure is available to users as defined by the administrator (Clash Manager Configuration Form - Security Tab).
Note:
The CE must be at or below a Group Element Type. The Group Element is the element
that will be clash checked.
-
Select View>Clash Manager or at the Toolbar, select Clash Manager.
-
The 'Clash Manager' form is displayed. Select Tools>Clash Check CE, to initiate the Clash Check CE process.
-
The first time the user initiates the Clash Check CE process in a particular MDB, a personal clash set titled ' Userid/MDB' is created and displayed on the Clash Manager - Clash Set Data form. Update the default details, as required (see Notes on Personal Clash Set on the 'GUI for Clash Manager' - 'Clash Set Data Form' ). When the details are as required, click on the OK button.
Note:
Userid is the user’s windows UserId and not the Marine UserId. -
The personal clash set is run. The clashes can be viewed using the Clash Report. (Refer to Clash Report).
Note:
If a clash is resolved through deleting or relocating one or both of the clashing elements, records of the clash will become dormant when any clash set referencing the elements is re-run.