This procedure is available to users as defined by the administrator (Clash Manager Configuration Form - Security Tab).

Note:
The CE must be at or below a Group Element Type. The Group Element is the element that will be clash checked.

  1. Select View>Clash Manager or at the Toolbar, select Clash Manager.

  2. The 'Clash Manager' form is displayed. Select Tools>Clash Check CE, to initiate the Clash Check CE process.

  3. The first time the user initiates the Clash Check CE process in a particular MDB, a personal clash set titled ' Userid/MDB' is created and displayed on the Clash Manager - Clash Set Data form. Update the default details, as required (see Notes on Personal Clash Set on the 'GUI for Clash Manager' - 'Clash Set Data Form' ). When the details are as required, click on the OK button.

    Note:
    Userid is the user’s windows UserId and not the Marine UserId.

  4. The personal clash set is run. The clashes can be viewed using the Clash Report. (Refer to Clash Report).

    Note:
    If a clash is resolved through deleting or relocating one or both of the clashing elements, records of the clash will become dormant when any clash set referencing the elements is re-run.