Inline Equipment Components - Rectangular Centrifugal Fan r
- Last UpdatedJan 27, 2026
- 2 minute read
The task of creating an HVAC Component is initiated from the HVAC Window.
-
Select Inline Plant Equipment in the Categories dropdown list.
-
Select Centrifugal Fan r in the Available Type dropdown list to display the Centrifugal Fan window:
Note: A centrifugal fan can only be created as the first item in a HVAC branch.

-
Centrifugal Fans can be left or right handed, from the Type dropdown list, select Left or Right.
You are required to input the following dimensions:
-
Name(Ref)
-
Rect width AA
-
Rect depth AB
-
Circular Diameter
-
Centrifugal Fans can be left or right handed, from the Type dropdown list, select Left or Right.
-
Outside Diameter
-
Centreline Height
-
Circ Extension
-
-
To visualize how the dimensions equate to the actual piece of HVAC, select Picture to display a detailed drawing for Inline Plant Equipment Catalog - Centrifugal Fan.
The fields will be pre-populated with default dimensions. These dimensions are governed by the details defined in the HVAC Catalog.
-
Select Transpose width/depth to exchange Rect width AA dimension with the Rect depth AB dimension.
-
Specify a type of joint to use for the Rect Jnt (Rectangular Joint) and Circ Jnt (Circular joint). For a detailed description, see Create / Modify HVAC Components.
-
After selecting the type of joint to use for the Rect Jnt and Circ Jnt, enter the Circ Direction.
-
In the Circ Direction specify the axis that should be used. Valid axes are E (East), N (North), U (Up), -E (negative East), -N (negative North) or -U (Negative Up). X, Y, Z, -X, -Y or -Z.
-
In the Connect list, select Connect or Unchanged:
-
Select Connect (default when Create is selected) - connects the piece of HVAC to the previous one.
-
Select Unchanged (default when Modify is selected) - positions the piece of HVAC at the co-ordinates 0.00.
Note: Unchanged is usually used, when Modify is selected, it does not connect the piece of HVAC but positions it at 0.00, in effect in a floating position.
-
-
Select Defaults to reset all the fields back to when the Centrifugal Fan window was opened.
-
Select Fit to orientate the Centrifugal Fan to automatically match the outlet (p-leave) of the previous piece of HVAC to the inlet (p-arrive) of the next piece.
-
Select OK to create the Centrifugal Fan component and close the Centrifugal Fan Window. You will be returned to the HVAC Window.
-
Select Cancel to discard all the field changes and close the Centrifugal Fan window.