Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

Hull and Outfitting

Direction

  • Last UpdatedSep 17, 2024
  • 2 minute read

The basic ways of defining a direction are:

  • Direction attribute plus optional WRT. For example:

    HDIR OF /PIPE1 WRT /*

  • Cartesian direction. For example:

    N 45 W

  • Cartesian direction WRT to an element.

  • All Cartesian directions are returned in the axis of the owner of the current element. For example:

    (U WRT CE )

  • will return the Z axis of the current element relative to its owner.

    Q ( Z WRT /SCTN )

  • will return the Z axis direction of /SCTN relative to the owner of the current element. For example, if the result is required in world coordinates the current element must be the World or a Site.

  • FROM pos2 TO pos2. For example:

    FROM N 50 WRT CE TO N 100

  • Keyword AXES followed by a p-point or pline.

  • The CLOSEST keyword, which will find the closest element in a particular direction. The syntax is:

    >- CLOSEST type -+- WITH exp -.

                     |            |

                     ‘------------+- DIRECTION dir -+- EXTENT val -.

                                                    |              |

                                                    ‘--------------+--> cont

                                                        

             continued >-+- AFTER val -.

                         |             |

                         ‘-------------+- FROM ? -.

                                       |          |

                                       ‘----------+-->

  • In the above graph the keywords are:

  • EXTENT, which is how far to search in the direction specified, default 10M.

  • AFTER, or the distance along vector after which to start search, default 0M.

  • FROM, which specifies an alternative start point other than current element. This is of particular use for a branch where you might want to specify the HPOS or TPOS.

  • Examples are:

    CLOSEST DIR E

    CLOSEST BOX WITH ( PURP EQ ’FLOO’ ) DIR D WRT /* EXTENT 20M

    CLOSEST VALVE DIR N 45 U FROM E100 N200 U300

    CLOSEST BRAN HANG AFTER 2M