Endcuts for Asymmetrical T-bars (Profile Type 35)
- Last UpdatedNov 28, 2025
- 11 minute read
In most cases the end cuts for L-bars may be used also for asymmetrical T-bars that are close to L-bars (that means, where the flange only slightly extends outside the web on the mould side of the profile). However, in certain cases neither the endcuts for L-bars nor T-bars are appropriate. This paragraph contains some endcut types that are specific for asymmetric T-bars.
Type 40:

Remarks:
-
This endcut type is intended for asymmetric T-bars (profile type 35) with a comparatively small "overshoot" of the flange (less than half the flange width) on the mould line side of the web
-
a 4 is by default 90 degrees. Any given value will override this default value.
Code, parameters
R1
a2
a3
4001, b, c[, a1, a4]
4002, b, c[, a1, a4]
4011, b, c[, a1, a4]0
0
3530
30
3030
18
304012, b, c[, a1, a4]
4031, b, c[, a1, a4]
4032, b, c[, a1, a4]35
75
7530
30
3018
30
184041, b, c[, a1, a4]
4042, b, c[, a1, a4]60
6030
3030
18
Type 41:

Remarks:
-
This endcut type is intended for asymmetric T-bars (profile type 35) with a comparatively large "overshoot" of the flange (larger than half the flange width) on the mould line side of the web.
-
a 4 is by default 90 degrees. Any given value will override this default value.
|
Code, parameters |
R1 |
a2 |
a3 |
|
4101, b, c[, a1, a4] |
0 |
30 |
30 |
|
4112, b, c[, a1, a4] |
35 |
30 |
18 |
|
4141, b, c[, a1, a4] |
60 |
30 |
30 |
Type 42:

Remarks:
-
This endcut type is intended for asymmetric T-bars (profile type 35) with a comparatively small "overshoot" of the flange (less than half the flange width) on the mould line side of the web
-
a 4 is by default 90 degrees. Any given value will override this default value.
|
Code, parameters |
R1 |
a2 |
|
4201, c[, a1, a4] |
0 |
30 |
Type 43:

Remarks:
-
This endcut type is intended for asymmetric T-bars (profile type 35) with a comparatively large "overshoot" of the flange (larger than half the flange width) on the mould line side of the web.
-
a 4 is by default 90 degrees. Any given value will override this default value
.
|
Code, parameters |
R1 |
a2 |
|
4301, c[, a1, a4] |
0 |
30 |
Type 132:

Remarks:
-
If c is not given (or =0), c will be set equal to the flange width a2 will become irrelevant and the flange angle will be set to a4.
-
This endcut type is intended for asymmetric T-bars (profile type 35) with a comparatively small "overshoot" of the flange (less than half the flange width) on the mould line side of the web.
|
Code, parameters |
R1 |
a2 |
|
13201, b[,c, a1, a4] |
35 |
18 |
Type 133:

Remarks:
-
If c is not given (or =0), c will be set equal to the flange width a2 will become irrelevant and the flange angle will be set to a4.
-
This endcut type is intended for asymmetric T-bars (profile type 35) with a comparatively small "overshoot" of the flange (less than half the flange width) on the mould line side of the web.
|
Code, parameters |
R1 |
a2 |
|
13301, a, b[,c, a1, a4] |
35 |
18 |
Type 134:

Remarks:
-
If c is not given (or =0), c will be set equal to the flange width a2 will become irrelevant and the flange angle will be set to a4.
-
This endcut type is intended for asymmetric T-bars (profile type 35) with a comparatively large "overshoot" of the flange (larger than half the flange width) on the mould line side of the web.
|
Code, parameters |
R1 |
a2 |
|
13401, b[,c, a1, a4] |
35 |
18 |
Type 135:

Remarks:
-
If c is not given (or =0), c will be set equal to the flange width a2 will become irrelevant and the flange angle will be set to a4.
-
This endcut type is intended for asymmetric T-bars (profile type 35) with a comparatively large "overshoot" of the flange (larger than half the flange width) on the mould line side of the web.
|
Code, parameters |
R1 |
a2 |
|
13501, a, b[,c, a1,a4] |
35 |
18 |
Type 136:

Remarks:
-
If c is not given (or =0), c will be set equal to the flange width a2 will become irrelevant and the flange angle will be set to a4.
-
The small sketch to the right shows how a small notch may be defined below the end of the flange
-
This endcut type is intended for asymmetric T-bars (profile type 35) with a comparatively large "overshoot" of the flange (less than half the flange width) on the mould line side of the web.
|
Code, parameters |
R1 |
R2 |
a2 |
|
13601, b[,c, a1, a4] |
35 |
55012 |
18 |
Type 137:

Remarks:
-
If c is not given (or =0), c will be set equal to the flange width a2 will become irrelevant and the flange angle will be set to a4.
-
The small sketch to the right shows how a small notch may be defined below the end of the flange.
-
This endcut type is intended for asymmetric T-bars (profile type 35) with a comparatively large "overshoot" of the flange (less than half the flange width) on the mould line side of the web.
|
Code, designation |
R1 |
R2 |
a2 |
|
13701, a, b[,c, a1, a4] |
35 |
55012 |
18 |
Type 138:

Remarks:
-
If c is not given (or =0), c will be set equal to the flange width a2 will become irrelevant and the flange angle will be set to a4.
-
The small sketch to the right shows how a small notch may be defined below the end of the flange.
-
This endcut type is intended for asymmetric T-bars (profile type 35) with a comparatively small "overshoot" of the flange (less than half the flange width) on the mould line side of the web.
|
Code, parameters |
R1 |
R2 |
a2 |
|
13801, b[,c, a1, a4] |
35 |
55012 |
18 |
Type 139:

Remarks:
-
If c is not given (or =0), c will be set equal to the flange width a2 will become irrelevant and the flange angle will be set to a4.
-
The small sketch to the right shows how a small notch may be defined below the end of the flange.
-
This endcut type is intended for asymmetric T-bars (profile type 35) with a comparatively small "overshoot" of the flange (less than half the flange width) on the mould line side of the web.
|
Code, parameters |
R1 |
R2 |
a2 |
|
13901, a, b[,c, a1, a4] |
35 |
55012 |
18 |
Type 153:

Remarks:
-
If c is not given (or =0), c will be set equal to the flange width a2 will become irrelevant and the flange angle will be set to a4.
-
The small sketch to the left shows the parameters of the corner notch.
-
This endcut type is intended for asymmetric T-bars (profile type 35) with a comparatively small "overshoot" of the flange (less than half the flange width) on the mould line side of the web.
|
Code, parameters |
R1 |
R2 |
a2 |
|
15301, a, b[,c, a1, a4] |
50 |
25 |
18 |
Type 157:

Remarks:
-
If c is not given (or =0), c will be set equal to the flange width a2 will become irrelevant and the flange angle will be set to a4.
-
The small sketch to the left shows the parameters of the corner notch.
-
This endcut type is intended for asymmetric T-bars (profile type 35) with a comparatively large "overshoot" of the flange (more than half the flange width) on the mould line side of the web.
|
Code, parameters |
R1 |
R2 |
a2 |
|
15701, a, b[,c, a1, a4] |
50 |
25 |
18 |
Type 160:

Remarks:
-
If c is not given (or =0), c will be set equal to the flange width a2 will become irrelevant and the flange angle will be set to a4.
-
This endcut type is intended for asymmetric T-bars (profile type 35) with a comparatively small "overshoot" of the flange (less than half the flange width) on the mould line side of the web.
|
Code, parameters |
R1 |
R2 |
a2 |
|
16001, b[,c, a1, a4] |
35 |
0 |
18 |
Type 161:

Remarks:
-
If c is not given (or =0), c will be set equal to the flange width a2 will become irrelevant and the flange angle will be set to a4.
-
The small sketch to the left shows the parameters of the corner notch.
-
This endcut type is intended for asymmetric T-bars (profile type 35) with a comparatively small "overshoot" of the flange (less than half the flange width) on the mould line side of the web.
|
Code, parameters |
R1 |
R2 |
a2 |
|
16110, a, b[,c, a1, a4] |
35 |
0 |
18 |
Type 162:

Remarks:
-
If c is not given (or =0), c will be set equal to the flange width a2 will become irrelevant and the flange angle will be set to a4.
-
The small sketch to the left shows the parameters of the corner notch.
-
This endcut type is intended for asymmetric T-bars (profile type 35) with a comparatively small "overshoot" of the flange (less than half the flange width) on the mould line side of the web.
|
Code, parameters |
R1 |
R2 |
a2 |
|
16201, a, b[,c,a1, a4] |
50 |
25 |
18 |
Type 163:

Remarks:
-
If c is not given (or =0), c will be set equal to the flange width a2 will become irrelevant and the flange angle will be set to a4.
-
This endcut type is intended for asymmetric T-bars (profile type 35) with a comparatively large "overshoot" of the flange (more than half the flange width) on the mould line side of the web.
|
Code, parameters |
R1 |
R2 |
a2 |
|
16301, b[,c, a1, a4] |
35 |
0 |
18 |
Type 164:

Remarks:
-
If c is not given (or =0), c will be set equal to the flange width a2 will become irrelevant and the flange angle will be set to a4.
-
This endcut type is intended for asymmetric T-bars (profile type 35) with a comparatively large "overshoot" of the flange (more than half the flange width) on the mould line side of the web.
|
Code, parameters |
R1 |
R1 |
a2 |
|
16401, a, b[,c, a1, a4] |
35 |
0 |
18 |
Type 165:

Remarks:
-
If c is not given (or =0), c will be set equal to the flange width a2 will become irrelevant and the flange angle will be set to a4.
-
The small sketch to the left shows the parameters of the corner notch.
-
This endcut type is intended for asymmetric T-bars (profile type 35) with a comparatively large "overshoot" of the flange (more than half the flange width) on the mould line side of the web.
|
Code, parameters |
R1 |
R2 |
a2 |
|
16501, a, b[,c, a1,a4] |
50 |
25 |
18 |
Type 167:

Remark:
If be equals the profile height aplha3 will be set to 90 deg.
|
Code, parameters |
R1 |
R2 |
a2 |
a3 |
|
16700, a, b[, a1] |
35 |
20010 |
18 |
30 |