When exporting Review Models that are to be used in conjunction with the AVEVA NET Spool highlighting functionality, the exported Review models must have some settings that are not normally used.

  1. The Implied Tubing must be set to Separate. Select Utilities > Export > Create to display the Export window.

  2. Click Representation to display the Export Representations window.

  3. Select Separate from the Implied Tube dropdown list.

    The reason that this is required is because SPLDRG’s are a secondary hierarchy within Marine and the Review model file does not actually contain this hierarchy. Because the SPOOL’s and FIELD’s of a SPLDRG can break in to the middle of a pipe’s Implied Tubing you need to export each Separate piece of tubing as a separate Review graphical object, and by default Marine Export will export the Implied Tube between components as one graphical item.

  4. To enable AVEVA NET to highlight the individual components of the SPLDRG, the Implied Tubing must be exported as separate parts. If this option is not set, no Spools will be visible within the AVEVA NET application.