Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

Hull and Outfitting

Posts (HRPOST)

  • Last UpdatedFeb 06, 2023
  • 1 minute read

The first HRPOST below the handrail assembly is used as a template for all posts within the design instance of handrail, the others, if any are ignored.

The post is placed along the RPATH by setting the ZDIStance and position reference to POINTR where the zdistance is measured from. So the HRPOST should be constructed symmetrically along its Z-axis and the lower end of post should be at its origin. If the offset is needed then ZOFFset or XOFFset of HRPOST can be specified. The application does not modify the offspring of HRPOST directly, it only sets principle attributes of HRPOST and then evaluates the attribute rules.

The attributes of HRPOST that are set by the application:

POSREF

ZDIS

XOFF (only the sign can be changed while the absolute value is kept).

All other attributes keep their initial value as specified in the assembly.