Hull and Outfitting

Trace Heating Specification Attribute

  • Last UpdatedNov 17, 2025
  • 1 minute read

Keywords:

TSPE

Description:

This attribute provides ISODRAFT with trace heating information. The trace heating Specification pointed to is a dummy Specification defined in SPECON, having no significance other than its name.

Example:

TSPE /TR50A

The Current Component will be noted by ISODRAFT with the given trace heating requirements.

TSPE NULREF

Trace heating is removed.

Note: If the same trace heating is required for an entire Branch, TSPE should be set at Branch level, from where it will cascade down to all new Components.

Command Syntax:

>-- TSPec --+-- name  ---.
            |            |
            ‘-- NULREF --+-->