HVAC Attributes - Orientation

  • Last UpdatedJan 07, 2026
  • 1 minute read
  1. Use the Orientation part of the HVAC window to modify the Leave Direction and Leave ‘A’ Axis of a HVAC component.

  2. You must first select the element to modify, from either the Design Explorer or the 3D View. In the example below a Rectangular Straight is highlighted in the Design Explorer.

  3. After selecting the element in the Design Explorer or 3D View, select CE to display the current orientation of the CE:

  4. Input the required direction in the Leave Direction and/or Leave ‘A’ Axis fields.

  5. Select Enter on the keyboard.

    The orientation of the CE will be updated with the input(s) in the 3D View.

    Leave Direction - Sets the Leave Direction for a piece of HVAC. Valid directions are X, Y, Z, -X, -Y or -Z.

    Leave ‘A’ Axis - Sets the rotation of the piece of HVAC relative to the Leave Direction. Valid dimensions are X, Y, Z, -X, -Y or -Z.