HVAC Structure Template

  • Last UpdatedDec 21, 2023
  • 1 minute read

The list of HVAC templates, for the HVAC STRT element to be supported, is filtered on the settings of two uda’s. They are :MdsHv (described in Filter Settings at a Piping or Tray Project Special Template) and :MdsRange and are both attributes of the STRU template.

The second filter control, :MdsRange, is implemented for HVAC templates only. It controls whether insulation exists on the HVAC STRT element being supported. The settings are shown in the table below:

Setting

Action

0

Restrict the STRU template to support only HVAC STRT elements that are uninsulated.

1

Restrict the STRU template to support only HVAC STRT elements that are insulated.

2, any other value, or left unset

Allow the STRU template to support HVAC STRT elements that are either uninsulated or insulated.

Having set the udas at the STRU templates, consider also :MdsCheck. Set this uda at the time the template is selected and/or built from the list displayed in the Select Project Special form. The options are shown in the table below:

Setting

Action

true

Include the insulation thickness of the HVAC STRT element in the design and build calculations of the STRU template members copied to the current MDS HVAC Special Support.

false

(default setting)

Exclude the insulation thickness of the HVAC STRT element in the design and build calculations of the STRU template members copied to the current MDS HVAC Special Support