Pipe Ends and their Connections

  • Last UpdatedJan 08, 2026
  • 1 minute read

Pipe ends will normally have specific text messages plotted next to them under the following circumstances:

  • At the start of a Pipe;

  • At the end of any type of off-line Branch;

  • At the end of a Pipe.

These messages show how the Pipe is continued from that point onwards, or any special Pipe end condition that may be required, as shown in the following examples.

Full XYZE-W, N-S and elevation (EL) coordinates will be listed for the start and finish of each Pipe. They will also be listed at the end of every Tee off-line branch; in other words, at all connection points.

Where a Pipe is connected to another Pipe, the coordinates will be preceded by a CONT. ON message. In the example image below, a Branch of PIPE-36A is the HREF or TREF of the Pipe shown.