The Doors and Window Room Design application will accept both fittings (SFIT) and template (TMPL) elements as doors or window elements. In the catalogue, these are referenced by GPART elements, and subsequently TABITEMS.

In order to work correctly with the Room Design application, the component orientation needs to be correctly aligned with the wall faces. The convention is that the face of a door that means, the opening direction is aligned with Z in the catalogue and the vertical direction of a door points in the –X direction.

The origin in the standard sample doors in the center of the door, but could easily be modelled as left or right depending on opening direction.

The same configuration is also applied to templates where the template primitives are arranged to provide the same basic orientation.