Record 1:

Distance of frame zero from the origin.

DELTA

Record 2:

Frame Spacing, repeated as often as required.

FRAME SPACING

where

FRAME

=

Frame No. of aft limit of frame spacing.

SPACING

=

Frame spacing until next frame.

Example:

0.1

-10 0.5

10 0.75

100 0.6

!

!

!

!

Frame 0 is 0.1 units from the origin

From frame -10 the frame spacing is 0.5

From frame 10 the spacing is 0.75

From frame 100 the frame spacing is 0.6