Attribute Category: Cabling
- Last UpdatedNov 20, 2025
- 2 minute read
|
Attribute Name |
Data Type |
Qualifier |
Description |
|---|---|---|---|
|
ACLIST |
element(500) |
Arriving cables to attached point |
|
|
ATCONN |
element(500) |
List of elements connected to attachment |
|
|
AYDIR |
dir |
Arrive Y axis direction |
|
|
CABBOX |
real(6) |
Calculated box volume in world coordinates |
|
|
CBACXR |
real |
Accumulated cables xarea at route node |
|
|
CBCOG |
pos |
Cable centre of gravity |
|
|
CBCULE |
real |
Cut Length of cable |
|
|
CBGELE |
real |
Geometric Length of cable |
|
|
CBNUCW |
element(500) |
Cables at a point on a cableway |
|
|
CBPREF |
element(500) |
References to POINTR forming route of a cable |
|
|
CBRNLS |
element(500) |
List of route nodes that cable passes |
|
|
CBRWGL |
real |
Raw Geometric Length of cable |
|
|
CBTOLE |
real |
Total Length of Cable |
|
|
CBWEIG |
real |
Cable weight |
|
|
CFILL |
real |
Fill level at route node |
|
|
CFRELE |
real |
Free Length of cable |
|
|
CLIST |
element(500) |
All cables attached to route node |
|
|
CMAXF |
real |
Calculate maximum fill level on cway |
|
|
CMINF |
real |
Calculate minimum fill level on cway |
|
|
CONATS |
element(500) |
List of attachment connected to attachment |
|
|
CONBRA |
element(500) |
List of branches connected to branch |
|
|
CONNE |
logical |
Segment end connection flag |
|
|
CONNS |
logical |
Segment start connection flag |
|
|
CONSIS |
logical |
Position consistency |
|
|
CWJUSL |
word |
Cable Way Justification Line |
|
|
CWLIST |
element(500) |
All cableways attached to route node |
|
|
DEPREF |
element(500) |
List of elements connected to branch tail |
|
|
ELCXRF |
element(500) |
Return reference from CABLE element to ELCONN element |
|
|
FCENTRE |
pos |
Centre of fillet arc |
|
|
FEND |
pos |
Fillet arc position |
|
|
Fill level check |
logical |
Fill level check |
|
|
FILREF |
element(500) |
Sorted references to attachment points with ascending order of fill level greater then 0 |
|
|
FLEVEL |
real |
Fill level at route node |
|
|
FMID |
pos |
Middle point of fillet arc |
|
|
FSTART |
pos |
Fillet start position |
|
|
HDCONN |
element(500) |
List of elements connected to branch head |
|
|
HDREF |
element(500) |
List of attachment connected to attachment |
|
|
LALCAB |
element(500) |
List arriving leaving cables on attached point |
|
|
LYDIR |
dir |
Leave Y axis direction on point |
|
|
MINFIL |
real |
Min Fill level on Cableway and Cabletray components |
|
|
NPLIST |
element(500) |
All NATPs attached to route node |
|
|
NUMCOR |
integer |
Number of cores in a cable |
|
|
POITYP |
string(120) |
Point type |
|
|
PRFELE |
element |
Cableway profile element |
|
|
PRFOBS |
integer |
Cableway profile obstructions |
|
|
RATTAL |
element(500) |
word |
Rnode list |
|
TLCONN |
element(500) |
List of elements connected to branch tail |
|
|
TLREF |
element(500) |
List of attachment connected to attachment |
|
|
TXAREA |
real |
Total Cableway X-area |
|
|
VRADI |
real |
Cableway radius |