The format of the DESIGN file, used to import Section Design data, is shown below. The Design file uses a common range of Waterlines to define a fixed 23 displacement stations as follows:

Station Range

Increment

0 - 1

1.5 - 4

5

6 - 8.5

9 - 10

0.25

0.5

0.5

0.25

Record 1:

Principal Dimensions

LPP    B   T   HS   HS   ROF   NWLS

where

LPP

B

T

D

HS

ROF

TH

NWLS

= Length between perpendiculars

= Moulded breadth

= Draft

= Height of topmost Waterline

= Half siding of keel

= Rise of Floor

= Mean thickness of shell plating

= Number of Waterlines

   (maximum No. 22)

Record 2:

Waterline Heights

0.0     Z(1)     Z(2) ...... Z(NWLS)

where Z( n )

=

Height of Waterline from baseline for each of NWLS Waterlines

Record 3:

Section offsets, repeated 23 times for standard stations

Y(0)   Y(1)......Y(NWLS)

where Y(0)

=

Flat of Bottom offset

          Y(1)

=

Section offsets measured from the centreline at each Waterline

Record 4:

Stern and Stem Data, repeated NWLS+1 times

STRN  STEM

where STRN

=

Distance of stern profile from the AP

         STEM

=

Distance of stem profile from the FP