Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

Hull and Outfitting

Running an Obstruction Box Check

  • Last UpdatedNov 14, 2025
  • 1 minute read

Keywords:

BOXCHECK

Description:

The BOXCHECK command initiates only a simplified (Stage 1) check for clashes between specified items (the check list) and the current obstruction list.

Examples:

BOXCHECK ALL

Checks all items in the design model (within any restrictions defined as in Sections 3.3 to 3.9) against the obstruction list.

BOXCHECK /ZONE1.PIPES

BOXCHECK /PUMP1 /PUMP2 /VESS2

BOXCHECK /GROUP.MOD2

BOXCHECK LEAVE TUBE FROM /FLAN2 IARRIVE TUBE TO /VALV5

Checks only specified items against the obstruction list.

Command Syntax:

                       .-----<------.
                      /             |
    >--- BOXCHeck ---*--- <clid> ---+---.
                     |                  |
                     ‘--- ALL ----------+--->

where <clid> (clashing item identifier) has the syntax shown in Running a Full Component Check.