Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

Hull and Outfitting

New Drawing Types for Automatic Drawing Production (ADP) - *12​.1​.SP3*

New Drawing Types for Automatic Drawing Production (ADP) - *12​.1​.SP3*

  • Last UpdatedMay 17, 2023
  • 2 minute read

Description

In 12.1.SP3 we have introduced some new marine drawing types that will be set for drawings generated with the ADP tools in Marine Drafting.

This will make it easier to access the drawings via the "Open Drawing" dialog in Marine Drafting. In the PADD database the new types are visible as new values for the MARPTYPE attribute of the SHEET element.

There are also corresponding project environment variables to set up where Marine Drafting should look for the drawing types in the "Open Drawing" dialog. The basic variable like "SB_HVAC_SKETCH_PDB" is normally just set to itself ("SB_HVAC_SKETCH_PDB") is the marine project setup file, while the "_PADD" variable should define the DEPARTMENT and REGISTRY where the drawings of this type are stored. Example of setup:

<var name="SB_HVAC_SKETCH_PDB">

<value><![CDATA[SB_HVAC_SKETCH_PDB]]></value>

</var>

<var name="SB_HVAC_SKETCH_PDB_PADD">

<value><![CDATA[HVACSketch;HVACSk]]></value>

</var>

Note:
The new drawing types will only be set when you run the ADP applications in Marine Drafting, they will not be set in Outfitting Draft.

Below is a summary of the new types:

Name of Drawing Type as Displayed
in the "Open Drawing" Dialog

Marptype

Environment variables

HVAC sketch

29

SB_HVAC_SKETCH_PDB SB_HVAC_SKETCH_PDB_PADD

*)Isometric ADP drawing

30

SB_ISOADP_PDB

SB_ISOADP_PDB_PADD

Steelwork Detailing ADP drawing

31

SB_STEELWORK_DETAIL_PDB

SB_STEELWORK_DETAIL_PDB_PADD

*)Area-Based ADP drawing

32

SB_ABAADP_PDB

SB_ABAADP_PDB_PADD

*)Multi-Discipline Support ADP drawing

33

SB_MDSADP_PDB

SB_MDSADP_PDB_PADD

*) - The drawing type is not yet active in Marine Drafting (since you cannot run these ADP tools in Marine Drafting yet) but they are reserved for future use.

Benefits

It is now easier to organize your ADP drawings and to list/open them in the "Open Drawing" dialog.

Compatibility Constraints

In order to see the new drawing types you must upgrade your PADD database(s) with the optional upgrade 12010301.