Extra Inline Equipment Components - Corner Mount LV Terminal
- Last UpdatedJan 19, 2026
- 3 minute read
The task of creating an HVAC Component is initiated from the HVAC Window.
-
Select Extra Plant Equipment in the Categories dropdown list.
-
Select Corner Mount LV Terminal in the Available Type dropdown list to display the Corner Mounting LVT window:

The Corner Mounting LVT window default is a standard stock size, but can be changed by using one of the following methods:
-
Standard Stock Sizes
-
Non-Standard Stock Sizes (Special)
-
Standard Stock Sizes
-
In the Name(Ref) field, enter the name of the HVAC component.
Note: The fields will be pre-populated with default dimensions. These dimensions are governed by the details defined in the HVAC Catalog.
-
To choose from the standard stock sizes available from the HVAC Catalog, in the Stock Size dropdown list, select the required dimension for the HVAC component.
-
In the Front Direction specify the axis that should be used. Valid axes are E (East), N (North), U (Up), -E (negative East), -N (negative North) or -U (Negative Up).X, Y, Z, -X, -Y or -Z.
The Face Clash Vol field is pre-populated with the obstruction volume associated with the Corner Mounting LVT and the ducting.
Non-Standard Stock Sizes (Special)
-
To choose a non-standard stock piece of HVAC, from the Stock Sizes dropdown list, select Special.
You are required to input the following dimensions:
-
Name(Ref)
-
Duct Diameter
-
Body Radius (A)
-
Body Length (B)
-
Body clHeight (D)
-
Arrive Extension
-
-
To visualize how the dimensions equate to the actual piece of HVAC, select Picture to display a detailed drawing for Extra Plant Equipment Catalog Element - LV Terminal for Corner Mounting.
Note: The fields will be pre-populated with default dimensions. These dimensions are governed by the details defined in the HVAC Catalog.
-
Specify a type of joint to use for the Arrjoint (Arrive Joint). For a detailed description, see Create / Modify HVAC Components.
-
After selecting the type of joint to use for the Arrjoint, enter the Front Direction.
-
In the Front Direction, specify the axis that should be used. Valid axes are E (East), N (North), U (Up), -E (negative East), -N (negative North) or -U (Negative Up).X, Y, Z, -X, -Y or -Z.
The Front Clash Vol field is pre-populated with the obstruction volume associated with the Corner Mounting LVT and the ducting.
-
In the Connect list, select Connect or Unchanged:
-
Select Connect (default when Create is selected) - connects the piece of HVAC to the previous one.
-
Select Unchanged (default when Modify is selected) - positions the piece of HVAC at the co-ordinates 0.00.
Note: Unchanged is usually used, when Modify is selected, it does not connect the piece of HVAC but positions it at 0.00, in effect in a floating position.
-
-
Select Defaults to reset all the fields back to when the Corner Mounting LVT window was opened.
-
Select Fit to orientate the Corner Mounting LVT to automatically match the outlet (p-leave) of the previous piece of HVAC to the inlet (p-arrive) of the next piece.
-
Select OK to create the Corner Mounting LVT component and close the Corner Mounting LVT Window. The user will be returned to the HVAC Window.
-
Select Cancel to discard all the field changes and close the Corner Mounting LVT window.