The positional errors for Fittings are measured as divergences of the Fitting positions from the Neutral Points of the attached Sections. The maximum permissible errors are defined, as for Sections, in terms of a Fitting’s eccentricity.

Keywords:

ECCENTRICITY FITTING

Description:

The ECCENTRICITY FITTING command specifies the maximum permissible distance between the position of a Fitting and that of its attached Section before a diagnostic message is output.

Examples:

ECC FITTING 1
(Default)

Maximum error in Fitting position is 1 mm

ECC FITT 0.5 INCH

Maximum error in Fitting position is 0.5 inch

ECC FITT DEF

Resets permissible Fitting position error to 1 mm

Command Syntax:

>--- ECCentricity --- FITTing ---+--- <uval> -----.
                                 |                |
                                 ‘--- DEFault ----+--->

Querying:

Q ECCentricity FITTing