Fill Level Check
- Last UpdatedNov 19, 2025
- 3 minute read
-
To check the fill levels, select Utilities > Fill Level Check to display the Fill Level Check window.

When the Fill Level Check window is first displayed it checks to see what the current element is and displays this information.
Load From contains four options: Site, Zone, Cableway and Cableway Branch and a refresh grid function.
-
Select where to Load From to populate the Select Cableway Branch grid. The grid displays the name of the Cableway Branch and the Max Fill Level.
Right-clicking within the grid displays a menu with two options:
Navigate to
Allows the user to navigate to the selected cableway branch in the Design Explorer
Highlight
Highlights the selected cableway branch in the 3D Graphical View
The branch selected in the Select Cableway Branch list is displayed in the Current Branch pane and its branch point elements are displayed in the Branch Points list. The elements are ordered from HEAD to TAIL and display the fill levels for each branch point.
The colours on each individual cell correspond to the value entered in the Fill Check Utility Allowance field on the Cabling Application Defaults window.
Green
If a cell is coloured green, then the maximum fill of the branch is greater than the fill level.
Yellow
If a cell is coloured yellow, then the fill level of the branch point is within the fill check allowance to the maximum fill of the cableway branch.
Red
If a cell is coloured red, then the fill level of the branch exceeds the maximum fill of the cableway branch.
Right-clicking within a cell displays a menu with three options:
Navigate to
Allows the user to navigate to the selected branch point in the Design Explorer.
List of Cables
Displays the List of Cables window with the selected branch point.
Export to Excel
Allows the user to export the grid to Excel
When a branch point is selected from the grid, graphical aids are displayed in the 3D Graphical View with the correct tag and position of the selected branch point.
-
To view an explanation of fill levels, select Explain Fill Levels to display the Fill Levels window.

The Connections pane displays if a branch point has a valid connection or not. Any valid connections are displayed, but if there is no valid connection, No Connections Associated is displayed.
Selecting a valid connection will navigate the you to that element in the Design Explorer and re-display the window to show the correct Cableway Branch selected and the branch point.
Note: If current element is a RATTA, RNODE, HATTA or TATTA when the window is first initialized the branch point is automatically selected.