Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

Hull and Outfitting

Controlling the Detailed Checking Procedure

  • Last UpdatedNov 10, 2025
  • 1 minute read

You can modify the effect of the CHECK command by using additional syntax so that you can check different types of catalog without generating unnecessary errors.

The command options are as follows:

TOLerance CATAlogue CMPRef ON/OFF—switches Component Reference checking on or off for all component types in a SPCO.

TOLerance CATAlogue CMPRef word ON/OFF—switches Component Reference checking on or off for the specified component type in a SPCO.

TOLerance CATAlogue GMREf ON/OFF—switches Geomset Reference checking on or off for all component types.

TOLerance CATAlogue GMREf word ON/OFF—switches Geomset Reference checking on or off for the specified component type.

TOLerance CATAlogue BORE ON/OFF—switches bore checking on or off for Pointsets.

TOLerance CATAlogue BORE value value—sets range of permissible bores to be checked for Pointsets.

TOLerance CATAlogue ISOMetric ON/OFF—checks for SKEY and similar Isodraft‑related settings.

TOLerance CATAlogue DEFault—resets all checking options to their default settings.

These defaults are:

  • Do not check any CMPREFs.

  • Ignore GMREF settings for ATTA, FLAN, TUBE and BOLT.

  • Check nominal bores in the range 6 mm to 2150 mm.

  • Check all Isodraft-related settings.

To query any of the current data consistency checking settings, use the corresponding command format

Q TOLerance CATAlogue ...