Format 3 (used with the controller FANUC15MB and variant V1, controller FANUC6 and variant Vi, controller FANUC9 and variant V1 and controller PDF32 with variance V1) of the file is as follows. Note that side is specified as '-' for the default case when there is no bevel angle. 'TS' represents 'This side' and 'OS' represents 'Other Side'. Comment lines are introduced by '#'. There is no interpolation with this format purely retrieval of required values to be output after the relevant auxiliary function codes.

#

# plate

# thickness

angle

side

kerf

voltage

Feed rate

Delay

#

# thickness 12 mm

12

0

-

01

140

50

1

12

10

TS

02

150

90

1

12

10

OS

03

150

90

1

Note: The Kerf values are input as Kerf Offset codes for example, register 01, 02.