Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

Hull and Outfitting

JOINTNUMBERS

  • Last UpdatedAug 22, 2024
  • 1 minute read

Function:

Numbering joints in Spool Drawings on an isometric.

Description:

By default SPOOLER automatically generates numbers for every joint in a Spool Drawing. These numbers can be output on an isometric by switching JOINTNumbers ON.

Note:
This function has no effect when plotting isometrics from the Design database.

The joints are sequentially numbered from one end of the Spool Drawing, with each number being given a prefix indicating the type of joint. The default prefixes are:

  • F    Flange

  • S    Screwed

  • C Compression

    Note:
    The ‘F, S & C’ codes are ATexts, and can be changed.

The numbers are displayed in a diamond, with an arrow pointing to the joint. If the total number of characters (prefix + number) is greater than 3, the number is displayed in angled brackets; for example, <FL124>.

Examples:

JOINTN ON

Switches joint numbering on

JOINTN OFF

Switches joint numbering off.

Related Commands:

PBENDNUMBERS WELDNUMBERS

Syntax Graph:

>--- JOINTNumbers ---+--- ON ----.
                     |           |
                     ‘--- OFF ---+--->

Querying:

Q JOINTNumbers