The task of creating an HVAC Component is initiated from the HVAC Window.

  1. Select Inline Plant Equipment in the Categories dropdown list.

  2. Select CIRCULAR Silencer c in the Available Type dropdown list to display the Circular Silencer window:

    You are required to input the following dimensions:

    • Name(Ref)

    • Duct Diameter

    • Outer Diameter

    • Overall Length

    • Extension (A)

    • Extension (L)

    • Male Collar (A)

    • Male Collar (L)

  3. To visualize how the dimensions equate to the actual piece of HVAC, select Picture to display a detailed drawing for Inline Plant Equipment Catalog - Circular Silencer.

    Note: The fields will be pre-populated with default dimensions. These dimensions are governed by the details defined in the HVAC Catalog. The Extension (A) and Extension (L) default is auto but can be changed by the user to a required dimension.

  4. Select Transpose width/depth to exchange Duct Width AA dimension with the Duct Width AB dimension.

  5. Specify a type of joint to use for the Arrjoint (Arrive Joint) and Leajoint (Leave joint). For a detailed description, see Create / Modify HVAC Components.

  6. In the Connect list, select Connect or Unchanged:

    • Select Connect (default when Create is selected) - connects the piece of HVAC to the previous one.

    • Select Unchanged (default when Modify is selected) - positions the piece of HVAC at the co-ordinates 0.00.

    Note: Unchanged is usually used, when Modify is selected, it does not connect the piece of HVAC but positions it at 0.00, in effect in a floating position.

  7. Select Defaults to reset all the fields back to when the Circular Silencer window was opened.

  8. Select Fit to orientate the Circular Silencer to automatically match the outlet (p-leave) of the previous piece of HVAC to the inlet (p-arrive) of the next piece.

  9. Select OK to create the Circular Silencer component and close the Circular Silencer window. You will be returned to the HVAC Window.

  10. Select Cancel to discard all the field changes and close the Circular Silencer window.