Integration UDA Definition
- Last UpdatedFeb 19, 2026
- 1 minute read
The UDAs must be defined in Lexicon if the matching process is to use them for storing source database references, refer to Instrumentation, Electrical and P&ID Elements Matching.
The UDAs may be created in any UGROUP in a current dictionary database. If used in conjunction with the specific module, it is suggested to include these UDAs in the same group.
The Integration UDAs should be created as Indexed UDAs with the following details:
|
UDA Name(s) |
UDA Type |
UDA Length |
Element Types |
|---|---|---|---|
|
pmg-sch-ai |
text |
50 |
SCINSTRUMENT SCOINSTRUMENT SCLOOP SCVALV SCACTUATOR |
|
pmg-sch-ae |
text |
50 |
SCEQUIPMENT |
|
pmg-engi-ai pmg-engi-ae pmg-engi-pid |
text text text |
50 50 150 |
Tags Instrumentation UDET(s) Tags Electrical UDET(s) Tags P&ID UDET(s) |
|
pmg-design-ai |
text |
50 |
CABLE EQUIPMENT INSTRUMENT SUBEQUIPMENT |
|
pmg-design-ae |
text |
50 |
CABLE EQUIPMENT |
|
pmg-cata-ai pmg-cata-ae |
text |
50 |
TABITEM GPART CABDATA SCOMPONENT CCORSET CABCORE TABQUESTION |
Note: In order to store the source database references for elements already imported, re-run Compare/Update on the existing data, accept all rows even though there are no changes listed, and complete the Update Database process.