List of All Attributes
- Last UpdatedFeb 09, 2023
- 68 minute read
|
Attribute Name |
Data Type |
Qualifier |
Description |
|---|---|---|---|
|
AALLAN |
real |
Arrive Ppoint allowed angle |
|
|
AANGXZ |
real |
Angle of attached SCTN in XZ plane of joint |
|
|
AANGYZ |
real |
Angle of attached SCTN in YZ plane of joint |
|
|
ABLE |
integer |
Minimum abbreviation length for a UDA/UDET user defined name |
|
|
ABOP |
pos |
Bottom of arrive pipe |
|
|
ABOR |
real |
Arrive bore |
|
|
ABRE |
string(8) |
Abbreviation |
|
|
ACBO |
string(1000) |
Actual bore |
|
|
ACCDIR |
dir |
Access Direction |
|
|
ACCELE |
real(500) |
Elevations of Referenced Levels |
|
|
ACCESSDB |
string(10) |
DB access |
|
|
ACCIDENT |
real |
Accident level radiation |
|
|
ACCLEV |
real(500) |
Access Heights for Stairwell |
|
|
ACCREF |
element |
Reference to Access element |
|
|
ACCTYP |
word |
Access type |
|
|
ACDATE |
string(50) |
Date last modified in AutoCAD |
|
|
ACDSTY |
string(120) |
AutoCAD Dimension style |
|
|
ACDWT |
string(120) |
AutoCAD drawing template name |
|
|
ACEXPO |
string |
AutoCAD export flag |
|
|
ACLASS |
word(100) |
Access Control Attribute class |
|
|
ACLAYE |
string(120) |
AutoCAD layer name |
|
|
ACLIST |
element(500) |
Arriving cables to attached point |
|
|
ACLOCK |
string |
AutoCAD picture lock |
|
|
ACNAME |
string(120) |
AutoCAD name |
|
|
ACON |
word |
Arrive connection type |
|
|
ACORRO |
real |
Arrive corrosion allowance |
|
|
ACPICT |
string |
AutoCAD picture flag |
|
|
ACPO |
element |
Access port reference |
|
|
ACRF |
element |
ACR reference attribute |
|
|
ACRGRP |
element(5000) |
List of ACRs within a ACRSET |
|
|
ACRLI |
element(1000) |
Access Control User assigned ACRs |
|
|
ACRMESSAGE |
string(120) |
Access Control User defined message |
|
|
ACSCAL |
real |
AutoCAD picture scale factor |
|
|
ACSTYF |
element |
Annotation change style reference |
|
|
ACTANG |
real |
Actual angle of a bend |
|
|
ACTL |
real |
Actual length |
|
|
ACTNCU |
integer |
Actual number of cuts of a bend |
|
|
ACTRAD |
real |
Actual radius of a bend |
|
|
ACTTYPE |
word |
Type of element, truncating non UDETs to 4 or 6 characters |
|
|
ADDSEGMENTS |
logical |
Auto creating segments flag |
|
|
ADEFRF |
element |
Reference to master ASSDEF |
|
|
ADEG |
real |
Orientation |
|
|
ADEN |
real |
Addition factor (unit definition) |
|
|
ADESP |
real(100) |
Design parameters of attached element |
|
|
ADIR |
dir |
Arrive direction |
|
|
ADMLOC |
element |
Currently administered location |
|
|
ADPRFA |
element(500) |
ADP reference array |
|
|
ADUUID |
string(40) |
PDMS Project GLOBAL UUID version string |
|
|
AELRFA |
element(500) |
Boundary components for the PipePiece |
|
|
AGRD |
real |
Arrive Ppoint gradient |
|
|
AHLIS |
word(200) |
List of actual types in owning hierarchy |
|
|
AIRCHA |
real |
Air Change Rate |
|
|
AIRT |
string(120) |
Air tight control method |
|
|
AKEY |
word |
Attribute key |
|
|
AKEYL |
word(20) |
Attribute-keylist (for Radial dimensions) |
|
|
ALCODE |
integer(10) |
Alarm code array |
|
|
ALENGTH |
real |
Arrive length |
|
|
ALIGN |
string |
Vertical alignment |
|
|
ALIST |
element(500) |
||
|
ALLANG |
string(1000) |
Connection allowable rotational angle |
|
|
ALLELE |
element(10000) |
elemtype |
All elements in the MDB of a particular type |
|
ALLO |
real |
Allowance |
|
|
ALTDEF |
element |
Alternative Def |
|
|
AMAPNM |
string(120) |
Local Name of Proxy actual member |
|
|
AMEMRF |
element |
Reference to a design model object |
|
|
AMPMPN |
string(120) |
Local Name of Proxy in Association |
|
|
ANGFR |
real |
Angle between assembly and frame plane |
|
|
ANGL |
real |
Angle |
|
|
ANGLSP |
real(10000) |
ANGLE Spacing |
|
|
ANGSPA |
real |
Springback angle at 20 degrees |
|
|
ANGSPB |
real |
Springback angle at 120 degrees |
|
|
ANGWL |
real |
Angle between assembly and water-line plane |
|
|
ANPJ |
pos |
Attached neutral point of joint (steelwork) |
|
|
ANPS |
pos |
Attached neutral point of section (steelwork) |
|
|
ANSTYP |
word |
Type of answer NONE, REAL, WORD, TEXT or BOOL |
|
|
ANSW |
real |
Answer, when a real is expected |
|
|
ANTY |
string(120) |
Analysis type |
|
|
ANYCHA |
logical |
True if chamfer is defined on any edge |
|
|
AOBJS |
element(500) |
Reference Array of all Model currently participating in ASSOCs |
|
|
AOD |
real |
Arrive Ppoint outside diameter |
|
|
APAR |
real(100) |
Attached catalogue parameters |
|
|
APARMS |
real(9) |
All parameters |
|
|
APDT |
string(12) |
Date of approval |
|
|
APOF |
real(2) |
Leaderline attachment point |
|
|
APOS |
pos |
Arrive position |
|
|
APOSE |
real |
Easting of arrive position |
|
|
APOSN |
real |
Northing of arrive position |
|
|
APOSU |
real |
Upping of arrive position |
|
|
APPL |
string(20) |
Application |
|
|
APPR |
string(1000) |
Approver |
|
|
APRO |
real |
Spot value of property A |
|
|
AQAANG |
real |
Angle between alignment direction of arrive pp and previous |
|
|
AQANG |
real |
Angle between arrive Ppoint and previous component |
|
|
AQBORE |
logical |
TRUE if arrive Ppoint has same bore as previous |
|
|
AQCON |
logical |
TRUE if arrive Ppoint has Correct connection type |
|
|
AQOFF |
real |
Offset between arrive Ppoint and previous component |
|
|
AREA |
integer |
Area |
|
|
AREAEX |
logical |
True if area exists for DB |
|
|
AREARE |
element |
Area reference |
|
|
ARNO |
integer |
Picture directory area number |
|
|
ARRHEI |
real |
Arrive height |
|
|
ARRI |
integer |
Arrive Ppoint |
|
|
ARRWID |
real |
Arrive width |
|
|
ASBPAN |
element |
Assembly base panel reference |
|
|
ASBUIL |
string(1000) |
Assembly build strategy |
|
|
ASCODE |
string |
Anno selection code |
|
|
ASDEST |
string(120) |
Assembly destination |
|
|
ASECOG |
real(3) |
Assembly estimated centre of gravity |
|
|
ASEWEI |
real |
Assembly estimated weight |
|
|
ASIOWN |
element(500) |
Assembly item referring to element |
|
|
ASIQUA |
integer |
Assembly item quantity |
|
|
ASLSBSTANDARD |
element |
ASL Substandard Reference |
|
|
ASLSTANDARD |
element |
ASL Standard Reference |
|
|
ASMBLD |
logical |
True if element is assembled |
|
|
ASMBLR |
element |
Assembly reference |
|
|
ASMBLS |
string |
A for assembled elements, NA for not assembled elements |
|
|
ASMBLX |
string(120) |
Assembly reference as text |
|
|
ASMBS |
element(500) |
Reference Array of all association members using element |
|
|
ASMOWN |
element(500) |
Assembly referring to element |
|
|
ASNAME |
string(50) |
Local assembly name |
|
|
ASORI |
integer |
Predefined assembly orientation |
|
|
ASORIS |
string(20) |
Predefined assembly orientation string |
|
|
ASPART |
logical |
True if assembly part. |
|
|
ASPLNO |
integer |
Number of assembly plate parts |
|
|
ASPRNO |
integer |
Number of profiles on assembly part |
|
|
ASPWLE |
integer |
Total length of weld in assembly part |
|
|
ASREF |
element |
Assembly reference |
|
|
ASRF |
element |
ADP annotation symbol library ref |
|
|
ASSCIA |
element(500) |
Reference Array of all associate elements used with constraints |
|
|
ASSDFS |
element(500) |
Reference Array of all ASSDEFs |
|
|
ASSEQ |
integer |
Assembly sequence |
|
|
ASSNTS |
element |
Reference to assembly nest (valid for individual nest only) |
|
|
ASSOS |
element(500) |
Reference Array of all associations with constraints |
|
|
ASSTAR |
element |
Association Target Reference |
|
|
ASSTMPREFERENCE |
element |
Assembly Template Reference |
|
|
ASTAB |
word(15) |
ADP association table |
|
|
ASTMBS |
element(500) |
Reference Array of all association members targeting element |
|
|
ASUB |
real |
Angle subtended |
|
|
ASWLOC |
string(120) |
Assembly working location |
|
|
ATCONN |
element(500) |
List of elements connected to attachment |
|
|
ATCORR |
real |
Arrive tube corrosion allowance |
|
|
ATEX |
string(1000) |
Unintelligent text string |
|
|
ATLE |
real |
Length of arrive implied tube |
|
|
ATLS |
word(50) |
Access type list |
|
|
ATNA |
word |
Attribute name |
|
|
ATOL |
integer |
Arc tolerance |
|
|
ATOP |
pos |
Top of arrive pipe |
|
|
ATQUALIFIER |
string(4000) |
Attribute qualifier |
|
|
ATTC |
word |
Attached connection type |
|
|
ATTDST |
word(2000) |
List the distributed attributes, default gives all udas |
|
|
ATTLIST |
word(2000) |
List of all attributes for element |
|
|
ATTMOD |
logical |
attr |
True if specified attribute has been modified this session |
|
ATTMODC |
logical |
attr |
True if specified attribute has been modified since comparison date |
|
ATTMODLIST |
word(500) |
integer |
List of attributes modified since given session |
|
ATTMODLISTC |
word(500) |
List of attributes modified since comparison date |
|
|
ATTNAM |
string(32) |
Attribute Name expression for ATTRRL elements |
|
|
ATTOUT |
word(2000) |
List of all attributes excluding hidden ones, i.e as output in "Q ATT" |
|
|
ATTRAW |
word(2000) |
List of raw attributes |
|
|
ATTRUL |
string(1000) |
Attribute Rule expression for ATTRRL elements |
|
|
ATTSET |
word |
Set attribute with result |
|
|
ATTY |
word |
Attachment type |
|
|
ATWALL |
real |
Arrive tube wall thickness |
|
|
ATWLEN |
real |
Assembly total weld length |
|
|
ATWREF |
element |
Arrive tube wall thickness reference |
|
|
AUTCOL |
real(3) |
Design rgb autocolour |
|
|
AUTCRE |
logical |
Set true to automatically create bound element. |
|
|
AUTH |
string(1000) |
Author |
|
|
AVRAD |
real |
Average radius for a CTOR or RTOR |
|
|
AWALLT |
real |
Arrive wall thickness |
|
|
AWDARR |
logical |
Auto weld arrive flange |
|
|
AWDFLN |
logical |
Bending machine accepts autowelded flanges |
|
|
AWDLEV |
logical |
Auto weld leave flange |
|
|
AWDOWN |
integer(3) |
Table linking AWELD elements to piping components |
|
|
AWDREF |
element(20) |
Return reference to AWELD element |
|
|
AWELDS |
integer(20) |
Weld numbers of attached welds |
|
|
AXIDIR |
dir |
Axis direction applied to repeat |
|
|
AXIPOS |
pos |
Axis position applied to repeat |
|
|
AXSPRI |
logical |
Is principle Axes Symbol |
|
|
AXSSIZ |
real |
AXESYM nominal size |
|
|
AXSTYP |
word |
Axes Symbol type |
|
|
AYDIR |
dir |
Arrive Y axis direction |
|
|
AZDIR |
dir |
Arrive alignment direction |
|
|
AZID |
real |
Default Azimuth value |
|
|
AZIF |
real |
Azimuth attractor factor |
|
|
AZIL |
real(2) |
Azimuth limits (Min/Max) |
|
|
AZIS |
logical |
Azimuth set flag - ignore Azimuth values if FALSE |
|
|
BAEXSS |
real |
Bending Excess Arrive |
|
|
BAIN |
string |
Before/After indicator |
|
|
BANG |
real |
Beta angle |
|
|
BASETYPE |
word |
Base type for the user-defined element type |
|
|
BBFF |
element(500) |
Array of bounding Boundary Formers |
|
|
BCPY |
element |
Backward copy reference |
|
|
BDIA |
string(1000) |
Bolt diameter |
|
|
BEAD |
real |
Default Bearing value |
|
|
BEAF |
real |
Bearing attractor factor |
|
|
BEAL |
real(2) |
Bearing limits (Min/Max) |
|
|
BEAS |
logical |
Bearing set flag - ignore Bearing values if FALSE |
|
|
BELRFA |
element(500) |
All components in the PipePiece |
|
|
BELTYP |
integer(500) |
All component types in the PipeSpool |
|
|
BENDCORNERS |
logical |
Bend corners - true if fillet should be applied to the corners of kickplate |
|
|
BENDMACREFERENCE |
element |
Bending Machine reference |
|
|
BENDMC |
element |
Bending Machine Reference |
|
|
BENT |
logical |
Bent flag |
|
|
BEVCOD |
real(10) |
Bevel codes for edges |
|
|
BEVEL |
real |
Bevel |
|
|
BEVFLA |
real |
Bevel code, flange |
|
|
BEVLEN |
real(2) |
Lengths of bevel |
|
|
BEVLFT |
real |
Bevel code on left side of seam |
|
|
BEVLI |
real(3) |
Lengths of I-bevel |
|
|
BEVLV |
real |
Length of vertical bevel |
|
|
BEVLX |
real(3) |
Lengths of X-bevel |
|
|
BEVLY |
real(3) |
Lengths of Y-bevel |
|
|
BEVM |
real(2) |
Bevel codes along M1 and M2 curves |
|
|
BEVRGT |
real |
Bevel code on right side of seam |
|
|
BEVTXT |
string |
Bevel text |
|
|
BEVWEB |
real |
Bevel code, web |
|
|
BFCOLO |
integer |
Backface colour |
|
|
BFCONU |
integer |
Backface colour number |
|
|
BFLE |
string(1000) |
Out of plane flexibility factor for bends |
|
|
BFPN |
integer |
Backface pen |
|
|
BFRF |
element |
Reference to real Boundary Former |
|
|
BFSTREF |
element |
Backface linestyle Reference |
|
|
BFSTYL |
integer |
Backface linestyle |
|
|
BITE |
word(25) |
Bolt items |
|
|
BITL |
real(25) |
Bolt item lengths |
|
|
BJOINT |
string |
Bolt joint |
|
|
BKEY |
string(4) |
DRAFT user defined base symbol/skey name |
|
|
BLCKLM |
logical |
True if block limit seam |
|
|
BLEN |
real(200) |
Bolt length |
|
|
BLEXSS |
real |
Bending Leave Excess |
|
|
BLNK |
logical |
Auto-blanking flag |
|
|
BLRF |
element(10) |
Bolt reference array |
|
|
BLSLEN |
real |
Length of blasting contours |
|
|
BLTM |
string(3) |
Bolt method |
|
|
BLTR |
element |
Bolt reference |
|
|
BMAR |
real |
Auto-blanking margin |
|
|
BMAX |
integer |
Maximum bend number in current spool drawing |
|
|
BMCLOC |
logical |
True if bending machine bends clockwise |
|
|
BMLEVE |
real(100) |
Beam levels from owning element |
|
|
BNDARE |
real |
Boundary line area |
|
|
BNDOFF |
real |
Offset from boundary |
|
|
BOLTPARTNUMBERS |
integer(20) |
Spooling bolt part numbers |
|
|
BORE |
real |
Bore |
|
|
BOREAR |
real(10) |
Bore array |
|
|
BPANOR |
ori |
Curved base panel orientation |
|
|
BPANRE |
element |
Base panel reference |
|
|
BPOF |
real(4) |
Leader bend point offset |
|
|
BPRO |
real |
Spot value of property B |
|
|
BRACKE |
string |
Brackets code |
|
|
BRAD |
real |
Bend radius |
|
|
BRALNK |
element(20) |
Connectivity SCBRAN-BRANCH Link |
|
|
BRCOG |
pos |
Branch centre of gravity |
|
|
BRCONNECT |
element(5000) |
Branch member connections |
|
|
BREARE |
real |
Branch external surface area |
|
|
BREF |
element |
Branch Reference |
|
|
BRIARE |
real |
Branch internal surface area |
|
|
BRICOG |
pos |
Branch insulated centre of gravity |
|
|
BRIWEI |
real |
Branch insulated weight |
|
|
BRLEG |
element(5000) |
Branch members on the same leg |
|
|
BRLO |
integer |
Branch Positioning Status code (Router) |
|
|
BRNFAC |
real |
Burning factor |
|
|
BRNLEN |
real |
Length of burning contours |
|
|
BRNNAM |
string(26) |
Burner name |
|
|
BRNNUM |
integer |
Burner number |
|
|
BRNPRC |
string(26) |
Burner process name |
|
|
BRNREF |
string(26) |
Burner reference id |
|
|
BRNSEQ |
string(26) |
Burning sequence number |
|
|
BRNST |
integer |
Number of starts for burning |
|
|
BRNTOO |
integer |
Burner tool |
|
|
BRNTYP |
string(26) |
Burner type |
|
|
BRREF |
element |
Branch table reference |
|
|
BRTXRF |
element(500) |
Return reference from Branch Table element to SPECs |
|
|
BRWCOG |
pos |
Branch wet centre of gravity |
|
|
BRWEIG |
real |
Branch weight |
|
|
BRWICOG |
pos |
Branch wet insulated centre of gravity |
|
|
BRWIWEI |
real |
Branch insulated wet weight |
|
|
BRWWEI |
real |
Branch wet weight |
|
|
BSCANG |
real |
Bend Segment Cut Angle |
|
|
BSCLL |
real |
Centre-Line Length of a miterd Bend Segment |
|
|
BSDWG |
string(120) |
AutoCAD backing sheet name |
|
|
BSEL |
string(3) |
Bolt Selector |
|
|
BSFN |
string(1024) |
Backing sheet filename |
|
|
BSLAYE |
string(120) |
AutoCAD backing sheet layer |
|
|
BSMNIL |
real |
Minimum Length of Insulation of a miterd Bend Segment |
|
|
BSMNL |
real |
Minimum Length of a miterd Bend Segment |
|
|
BSMXIL |
real |
Maximum Length of Insulation of a miterd Bend Segment |
|
|
BSMXL |
real |
Maximum Length of a miterd Bend Segment |
|
|
BSPE |
element |
Bolt specification |
|
|
BSRF |
element |
Backing sheet reference |
|
|
BSRFA |
element(500) |
ADP backing sheet list |
|
|
BSTA |
integer |
Branch Status code (Router) |
|
|
BTEX |
string(1000) |
Annotation text string |
|
|
BTHK |
string(1000) |
parameterized bolt thickness |
|
|
BTLS |
word(50) |
Boundary Former type list |
|
|
BTOL |
string(1000) |
Bore tolerance |
|
|
BTOTAL |
integer |
Bolt joint total |
|
|
BTYP |
string(1000) |
Bolt type |
|
|
BUFS |
integer |
Preferred buffer size |
|
|
BUIL |
logical |
Built/Unbuilt flag |
|
|
BULG |
real |
Bulge factor |
|
|
BUNI |
word |
Bore units |
|
|
BUNREF |
element |
Cable bundle reference |
|
|
BURF |
element |
Reference to real Building Element |
|
|
BURNID |
string(80) |
Burner id |
|
|
BUYMARK |
string(26) |
Buying mark |
|
|
BVCODN |
integer |
Bevelled Code number |
|
|
BVIS |
logical |
Bottom visibility flag |
|
|
BVSCLL |
real |
Centre-Line Length of a miterd Bend Segment |
|
|
BVSEGN |
integer |
Bevelled segment number |
|
|
BVSMNI |
real |
Minimum Length of Insulation of a Virtual miterd Bend end-Segment |
|
|
BVSMNL |
real |
Minimum Length of a virtual miterd Bend end-Segment |
|
|
BVSMXI |
real |
Maximum Length of Insulation of a Virtual miterd Bend end-Segment |
|
|
BVSMXL |
real |
Maximum Length of a virtual miterd Bend end-Segment |
|
|
BWITHF |
logical |
Bend with flow |
|
|
CABBOX |
real(6) |
Calculated box volume in world coordinates |
|
|
CABGAP |
real |
cable gap on cabletray as multiple of OUTD |
|
|
CABINT |
string(120) |
cable interference class |
|
|
CAGOFF |
real |
Cage Offset |
|
|
CAGSIZ |
real |
Cage Size |
|
|
CARD |
integer(2) |
Cardinality definition |
|
|
CARE |
string(12) |
Isodraft Compipe: Area |
|
|
CASR |
element |
Case reference |
|
|
CATMOD |
integer |
Catalogue Geometry Modified- Not directly query able |
|
|
CATR |
element |
Catalogue reference |
|
|
CATTEX |
string(725) |
Concatenation of Detailing and Material Texts |
|
|
CATY |
integer |
Card type |
|
|
CBACXR |
real |
Accumulated cables xarea at route node |
|
|
CBCOG |
pos |
Cable centre of gravity |
|
|
CBCULE |
real |
Cut Length of cable |
|
|
CBGELE |
real |
Geometric Length of cable |
|
|
CBNUCW |
element(500) |
Cables at a point on a cableway |
|
|
CBPREF |
element(500) |
References to POINTR forming route of a cable |
|
|
CBRNLS |
element(500) |
List of route nodes that cable passes |
|
|
CBRWGL |
real |
Raw Geometric Length of cable |
|
|
CBSTA |
integer |
Cable routing status |
|
|
CBTOLE |
real |
Total Length of Cable |
|
|
CBWEIG |
real |
Cable weight |
|
|
CCEN |
integer |
Cost centre |
|
|
CCLA |
integer |
Cost class |
|
|
CCOL |
integer |
Colour (in catalogue) |
|
|
CCON |
word |
Connection type |
|
|
CCORRE |
element |
Cable Core set reference |
|
|
CCORXR |
element(500) |
Return reference from CCORSET element to SCOMs |
|
|
CDET |
element |
Catalogue detail |
|
|
CDPL |
word(100) |
List of valid current design properties |
|
|
CDPR |
real |
word |
Current design dataset property |
|
CDRG |
string(24) |
Isodraft Compipe: Drawing number |
|
|
CELLID |
integer(2) |
Cell Identifier |
|
|
CELLTO |
real |
Total Number of Cell |
|
|
CELLTR |
real |
Total Number of Trimmed Cells |
|
|
CELLWH |
real |
Total Number of Untrimmed Cells |
|
|
CELREF |
element |
Status Element reference |
|
|
CEND |
string |
Connection at other end of CREF (HEAD or TAIL) |
|
|
CERF |
element(500) |
Array of Faces generated by this |
|
|
CEXES |
real(4) |
Cable excesses |
|
|
CEXS |
real |
Percentage excess for passing cables |
|
|
CFDP |
element |
word |
Current design dataset property |
|
CFFA |
element(500) |
Array of Faces generated by this |
|
|
CFILL |
real |
Fill level at route node |
|
|
CFRA |
element(10) |
Cofitting reference array for Pfittings |
|
|
CFRELE |
real |
Free Length of cable |
|
|
CHALEN |
real |
Length of chamfer intervals |
|
|
CHAM |
real(2) |
Chamfer lengths |
|
|
CHANUM |
integer |
Number of chamfer intervals |
|
|
CHAR |
integer |
Character set |
|
|
CHARGE |
string(80) |
Charge |
|
|
CHCOLO |
integer |
Crosshairs colour |
|
|
CHCONU |
integer |
Crosshairs colour number |
|
|
CHDCOLUMN |
element |
Child column |
|
|
CHECKE |
string(1000) |
Checker |
|
|
CHEI |
real |
Character height |
|
|
CHKDAT |
string(120) |
Date checked |
|
|
CHNGD |
integer |
Changed counter |
|
|
CHOS |
real |
Crosshairs overshoot |
|
|
CHPN |
integer |
Crosshairs pen |
|
|
CHSTREF |
element |
Crosshairs linestyle Reference |
|
|
CHSTYL |
integer |
Crosshairs linestyle |
|
|
CIRCR |
real(4) |
Circumscribed rectangle |
|
|
CIWE |
string(1000) |
Total insulation weight |
|
|
CKEY |
word |
ISODRAFT end condition key |
|
|
CLAI |
integer |
Claim mode |
|
|
CLAIMDB |
string(10) |
Implicit or explicit claims |
|
|
CLBASE |
real |
Column base offset |
|
|
CLCCNT |
integer |
Claim list changes count |
|
|
CLCOLO |
integer |
Centreline colour |
|
|
CLCONN |
element(5000) |
integer |
Clasher connections |
|
CLCONU |
integer |
Centreline colour number |
|
|
CLFG |
logical |
Centreline flag |
|
|
CLFL |
logical |
Centreline flag |
|
|
CLIPCD |
integer |
Clip code |
|
|
CLIST |
element(500) |
All cables attached to route node |
|
|
CLLE |
real |
Branch centreline length |
|
|
CLMID |
string(120) |
Unique system ID of user claiming element |
|
|
CLMNUM |
integer |
User or extract number claiming element. Extract numbers are negative |
|
|
CLMO |
string |
Centreline mode: 1=CL OFF, 2=CL ON |
|
|
CLMTIE |
element(4) |
Reference to elements that are automatically claimed along with this element |
|
|
CLNCOD |
string(120) |
Ceiling Code |
|
|
CLNELE |
real |
Ceiling Elevation |
|
|
CLNFAC |
real |
Cleaning factor |
|
|
CLNHEI |
real |
Ceiling Height |
|
|
CLNTYP |
string(120) |
Ceiling Type |
|
|
CLNVOI |
real |
Ceiling Void Height |
|
|
CLOSED |
logical |
True if plate covering entire referenced component |
|
|
CLOSEFLAG |
logical |
True if branch is closed |
|
|
CLPN |
integer |
Centreline pen |
|
|
CLRF |
element |
Actual circulation list reference |
|
|
CLRSIZ |
real(2) |
Clearance size |
|
|
CLSTREF |
element |
Centreline linestyle Reference |
|
|
CLSTYL |
integer |
Centreline linestyle |
|
|
CMALL |
real |
Structure allowance |
|
|
CMAXF |
real |
Calculate maximum fill level on cway |
|
|
CMBOUA |
element |
Aft boundary |
|
|
CMBOUF |
element |
Fwd boundary |
|
|
CMBOUL |
element |
Lower boundary |
|
|
CMBOUP |
element |
Ps boundary |
|
|
CMBOUS |
element |
Stbd boundary |
|
|
CMBOUU |
element |
Upper boundary |
|
|
CMBOX |
real(6) |
Bounding box |
|
|
CMCAT |
string(256) |
Compartment category |
|
|
CMCDE |
real |
Content density |
|
|
CMCTID |
string(256) |
Content type ID |
|
|
CMDESC |
string(256) |
Compartment description |
|
|
CMFLW |
real |
Full Load Weight |
|
|
CMINF |
real |
Calculate minimum fill level on cway |
|
|
CMLCV |
real |
Longitudinal centre of total volume |
|
|
CMMGE |
integer |
Merged compartment indicator |
|
|
CMPER |
real |
Compartment permeability |
|
|
CMPERD |
real |
Permeability for use in damage |
|
|
CMPLNK |
element |
Return reference from schematic or design element to CYMLNK element |
|
|
CMPR |
element |
Component reference |
|
|
CMPRFA |
element(500) |
All components for the PipePiece |
|
|
CMPSTATUS |
word |
Connectivity comparison status |
|
|
CMPSTS |
string(120) |
Connectivity comparison status description |
|
|
CMPURP |
string(256) |
Purpose |
|
|
CMTCV |
real |
Transverse centre of total volume |
|
|
CMTYP |
integer |
Type of compartment |
|
|
CMVCV |
real |
Vertical centre of total volume |
|
|
CMVOL |
real |
Total volume |
|
|
CNTNUM |
integer |
Contour number |
|
|
CNUM |
string(22) |
Isodraft Compipe: Line number |
|
|
COCDRE |
element(500) |
word |
COCDESS with same COCONN value as qualifier |
|
COCONN |
word |
COCO Connection type |
|
|
COCORE |
element(2) |
COCO description reference |
|
|
COCOXR |
element(500) |
COCO description return reference |
|
|
COCSAM |
element(500) |
COCOS with same CTYP value as COCDES |
|
|
COLCOL |
integer |
Column colour |
|
|
COLCON |
integer |
Column colour number |
|
|
COLNUM |
integer |
Pin column number |
|
|
COLSCH |
string(120) |
Color Schema |
|
|
COLSTREF |
element |
Column linestyle Reference |
|
|
COLSTY |
integer |
Column linestyle |
|
|
COLXSP |
real(100) |
Spacing between columns in the X direction of the tower |
|
|
COLYSP |
real(100) |
Spacing between columns in the Y direction of the tower |
|
|
COMBOO |
word |
Boolean Combination |
|
|
COMM |
string(120) |
Comment |
|
|
COMMST |
string(500) |
Comment string |
|
|
COMNT |
string |
Comment |
|
|
COMPEN |
logical |
Compensate bending activities for springback |
|
|
COMPTYPE |
word |
Type of component |
|
|
CONAM |
string |
Cutout name |
|
|
CONARR |
word(10) |
Connection array |
|
|
CONATS |
element(500) |
List of attachment connected to attachment |
|
|
CONBRA |
element(500) |
List of branches connected to branch |
|
|
CONCD |
integer |
Connection code |
|
|
COND |
integer(500) |
Access Control Logical condition |
|
|
CONDES |
string |
Connection string |
|
|
CONDGR |
integer |
No of Conductor Groups |
|
|
CONNE |
logical |
Segment end connection flag |
|
|
CONNECTIONS |
element(5000) |
Connections |
|
|
CONNECTIONSH |
element(5000) |
Connections for all descendants |
|
|
CONNER |
string(300) |
integer |
Connection error message |
|
CONNRE |
element(10) |
References to other element |
|
|
CONNS |
logical |
Segment start connection flag |
|
|
CONSIS |
logical |
Position consistency |
|
|
CONTYP |
string |
Connection type |
|
|
COPI |
integer |
Number of copies |
|
|
COPYDB |
element(8191) |
Copies of this database |
|
|
CORA |
string(1000) |
Corrosion thickness |
|
|
CORCGR |
string(120) |
integer |
cable core conductor group |
|
CORNUM |
integer |
Corner number |
|
|
CORNUV |
pos |
Corner point |
|
|
CORROS |
real |
Tube corrosion |
|
|
CORRUG |
logical |
True if corrugation is defined on the plate part |
|
|
CORTAG |
string(120) |
integer |
cable core tag |
|
COUN |
integer |
Counter |
|
|
CPAR |
real(100) |
Catalogue parameters |
|
|
CPEN |
integer |
Pen for internal columns |
|
|
CPFA |
element(500) |
Array of Ports this points to |
|
|
CPLO |
string(120) |
Plot (in catalogue) |
|
|
CPOF |
real(2) |
Leaderline connection point wrt. text origin |
|
|
CPOS |
pos |
conditioning position for curve geometry |
|
|
CPRO |
real |
Spot value of property C |
|
|
CPUL |
real(3) |
Cold pull - translational |
|
|
CPUT |
real(3) |
Cold pull - twist |
|
|
CRCANG |
real |
Turning angle for least circumscribed rectangle |
|
|
CRCLW |
real(2) |
Length and width of circumscribed rectangle |
|
|
CRDATE |
string(120) |
attr |
Date element created in current DB or if extract in ascendant |
|
CREANCESTORS |
logical |
Create ancestors |
|
|
CREF |
element |
Connection reference |
|
|
CREXTR |
integer |
attr |
Extract element created in current DB or if extract in ascendant |
|
CRFA |
element(10) |
Connection reference array |
|
|
CRINFO |
string(200) |
DB creation information |
|
|
CRIT |
integer(250) |
Selection criteria (used to define tag & rep. rules) |
|
|
CRSESS |
integer |
attr |
Session element created in current DB or if extract in ascendant |
|
CRSF |
element |
Change ruleset reference |
|
|
CRUSER |
string(120) |
attr |
User created element in current DB or if extract in ascendant |
|
CSESS |
string(120) |
integer |
Comment entered for specified session |
|
CSFBR |
logical |
Spooling marker for components |
|
|
CSGBOX |
real(6) |
CSG-Calculated box volume in world coordinates |
|
|
CSPA |
real |
Character spacing factor |
|
|
CSPC |
string(6) |
Isodraft Compipe: Specification |
|
|
CSTA |
string(120) |
Catalogue Standard |
|
|
CSTR |
element |
Constraint reference |
|
|
CTCREF |
element |
integer |
Cable tray component ref |
|
CTHICK |
real |
Coating thickness |
|
|
CTSPE |
element |
Cable tray specification |
|
|
CTTYP |
word |
Cable tray typ |
|
|
CTXT |
string(120) |
Card text |
|
|
CTYA |
word |
Attached connection type |
|
|
CTYE |
word |
End connection type |
|
|
CTYO |
word |
Owning connection type |
|
|
CTYP |
word(2) |
Connection type |
|
|
CTYPLI |
word(500) |
List of COCO Ctypes |
|
|
CTYS |
word |
Start connection type |
|
|
CURD |
element(1000) |
Current DBs |
|
|
CURF |
string |
Curve fitting code: 1 default, 2 cubicfit |
|
|
CURLOC |
element |
True current location |
|
|
CURREN |
string(1000) |
Current |
|
|
CURTYP |
word |
Curve type |
|
|
CURVED |
logical |
True if curved plate part. |
|
|
CUTB |
real |
Cutback |
|
|
CUTL |
real |
Cut length |
|
|
CUTNAM |
string(700) |
integer |
Full name of element, truncated to n characters |
|
CUTNMN |
string(700) |
integer |
Full name of element (without leading slash) truncated to n characters |
|
CUTP |
dir |
Cutting plane normal |
|
|
CWEI |
string(1000) |
Total component weight |
|
|
CWHEAD |
element(500) |
Cableway Head |
|
|
CWHPOS |
pos |
Cableway path head point position |
|
|
CWIDTH |
real |
Clearance Width |
|
|
CWJUSL |
word |
Cable Way Justification Line |
|
|
CWLIST |
element(500) |
All cableways attached to route node |
|
|
CWTAIL |
element(500) |
Cableway Tail |
|
|
CWTPOS |
pos |
Cableway path tail point position |
|
|
D |
real |
Position downing |
|
|
DACC |
string |
Database access |
|
|
DACCLA |
logical |
True if DAC allows element to be claimed |
|
|
DACCOH |
logical |
True if DAC allows element hierarchy to be copied to another DB |
|
|
DACCOP |
logical |
True if DAC allows element to be copied to another DB |
|
|
DACCRE |
logical |
elemtype |
True if DAC allows element to be created |
|
DACDEL |
logical |
True if DAC allows element to be deleted |
|
|
DACDRO |
logical |
True if DAC allows element to be dropped |
|
|
DACERR |
string(120) |
attr |
Returns the DAC error |
|
DACEXH |
logical |
True if DAC allows element hierarchy to be exported |
|
|
DACEXP |
logical |
True if DAC allows element to be exported |
|
|
DACISS |
logical |
True if DAC allows element to be issued |
|
|
DACMOD |
logical |
attr |
True if DAC allows attribute of element to be modified |
|
DACOUH |
logical |
True if DAC allows element hierarchy to be output |
|
|
DACOUT |
logical |
True if DAC allows element to be output |
|
|
DAREF |
element |
Reference of associated dataset area |
|
|
DARREF |
element |
Design area reference |
|
|
DASSCI |
element(500) |
Reference Array of all direct associates with constraints |
|
|
DASSOS |
element(500) |
Reference Array of all associations with constraints |
|
|
DATE |
string(12) |
Date |
|
|
DATEFO |
string |
Date format |
|
|
DATIM |
string(19) |
LMI Date/time |
|
|
DATINT |
integer(2) |
Date |
|
|
DATONE |
integer |
Date 1 |
|
|
DATTWO |
integer |
Date 2 |
|
|
DATTXT |
string(22) |
Date |
|
|
DBAC |
string |
DB Access, MULTIWRITE or UPDATE |
|
|
DBALL |
element(8000) |
List of DBs allocated to location |
|
|
DBCL |
string |
DB Claim |
|
|
DBCNTL |
logical |
True if element is in a control DB |
|
|
DBEXNO |
integer |
DB Extract Number |
|
|
DBF |
element |
Database reference attribute |
|
|
DBFI |
string |
DB filename |
|
|
DBFN |
integer |
DB file number |
|
|
DBLC |
element(1000) |
List of LOCs belonging to a DB |
|
|
DBLS |
element(1000) |
List of DBs belonging to MDB |
|
|
DBNA |
string |
DB name |
|
|
DBNU |
integer |
DB Number |
|
|
DBOT |
real |
Bottom diameter |
|
|
DBPR |
element(8000) |
List of DBs Primary at location |
|
|
DBRBEG |
integer |
DB range start |
|
|
DBREF |
element |
DB reference |
|
|
DBREND |
integer |
DB range end |
|
|
DBSESS |
integer |
Last DB session |
|
|
DBSHIE |
element(5000) |
Database hierarchy within a DBSET |
|
|
DBSLEV |
element(5000) |
Databases at a level within a DBSET |
|
|
DBSLIS |
element(5000) |
Databases within a DBSET |
|
|
DBSSTP |
element(8000) |
DBs in a stamp |
|
|
DBSTF |
element |
Database set reference attribute |
|
|
DBTE |
string |
DB Text Encoding |
|
|
DBTY |
word |
DB type (DESI, CATA etc) |
|
|
DBUsers |
element(10000) |
Current Users in the system using this DB |
|
|
DBUSRX |
element(10000) |
Current Users in the system using this DB or any extract descendants |
|
|
DBVAR |
logical |
True if element is in a variant DB |
|
|
DBVWSTREF |
element(50) |
Database View Set reference array |
|
|
DBWRITE |
logical |
True if element is in a writable DB |
|
|
DCLA |
string |
Database claim mode |
|
|
DCLNCO |
string(120) |
Default Ceiling Code |
|
|
DCLNHE |
real |
Default Ceiling Height |
|
|
DCLNTY |
string(120) |
Default Ceiling Type |
|
|
DCODE |
string |
Direction code |
|
|
DCON |
word |
Design PPoint connection type |
|
|
DCORRO |
real |
Derived corrosion |
|
|
DCRFA |
element(10) |
Array of Design datasets for Design Code/Criteria |
|
|
DCSTYF |
element |
Design change style reference |
|
|
DCTILT |
real |
Default Ceiling Tile Thickness |
|
|
DDDF |
string(1000) |
Default Design data value |
|
|
DDEF |
real(3) |
Port distance flexibility defaults |
|
|
DDEG |
real |
Dimension line angle |
|
|
DDEP |
integer |
Database depth within hierarchy (World is 0) |
|
|
DDESP |
real(100) |
Design parameters as distance |
|
|
DDIR |
dir |
Design PPoint spherical direction |
|
|
DDNM |
element |
Design element reference |
|
|
DDNMX |
real |
DDNM X position |
|
|
DDNMXY |
real(2) |
DDNM XY position |
|
|
DDNMY |
real |
DDNM Y position |
|
|
DDNX |
string(120) |
Design element as text |
|
|
DDOORS |
real |
Default Door Sill |
|
|
DDPR |
string(1000) |
Design data property value |
|
|
DDRFA |
element(10) |
Array of default design datasets (for template) |
|
|
DEALAL |
logical |
True if location locked due to deallocation of dbs |
|
|
DEALDB |
element(1000) |
Reference array for locations where DB id being deallocated |
|
|
DECGAP |
real |
Decoration Gap |
|
|
DECMOD |
integer |
Decoration Mode |
|
|
DECOFF |
real(2) |
Decoration offset |
|
|
DECP |
integer |
Decimal places |
|
|
DECREP |
real |
Decoration Repeat |
|
|
DECSIZ |
real |
Decoration Size |
|
|
DEFA |
real |
Default |
|
|
DEFATT |
word(2000) |
Default List of all attributes for element |
|
|
DEFERD |
element(10000) |
Deferred DBs in MDB |
|
|
DEFHOM |
element |
Default allocation home |
|
|
DEFSLO |
real |
Default pipe slope |
|
|
DEFSPK |
element |
Default Reference of SPEC for branch members |
|
|
DELANG |
real |
Angle applied to repeat elements |
|
|
DELDSG |
word |
Delivery Designation flag |
|
|
DELP |
pos |
D-position in structure |
|
|
DELPE |
real |
Easting of D-Position in STRUC |
|
|
DELPN |
real |
Northing of D-position in STRUC |
|
|
DELPU |
real |
Upping of D-position in STRUC |
|
|
DELTAE |
real |
Easterly Offset applied to repeat elements |
|
|
DELTAN |
real |
Northerly Offset applied to repeat elements |
|
|
DELTAU |
real |
Vertical Offset applied to repeat elements |
|
|
DEMIX |
integer |
Index of Demote Status Value |
|
|
DENS |
real |
Spot value of density |
|
|
DEPATT |
word(2000) |
Attributes that a rule or catalogue parameterized expression is dependent upon |
|
|
DEPD |
string(250) |
word |
Default value of local design property |
|
DEPL |
word(100) |
List of local design properties |
|
|
DEPR |
string(250) |
word |
Local design property value |
|
DEPREF |
element(500) |
List of elements connected to branch tail |
|
|
DESC |
string(120) |
Description of the element |
|
|
DESGEO |
element(5000) |
Design geometrical dependencies |
|
|
DESLNK |
element(20) |
Connectivity Design Model Link |
|
|
DESMOD |
integer |
Design Mode |
|
|
DESP |
real(100) |
Design parameters |
|
|
DESREF |
element(10) |
Design reference |
|
|
DEST |
string(26) |
Destination |
|
|
DESXCL |
logical |
Design Outfitting excluded Geometry |
|
|
DETA |
logical |
Detail flag |
|
|
DETR |
element |
Detailing text reference |
|
|
DFBRADIUS |
real |
element |
Default bend radius |
|
DFFL |
real(6) |
Displacement force flexibility |
|
|
DFHOME |
element |
element, elemtype |
Get default home element |
|
DFLA |
string |
Radial dimension type flag |
|
|
DFLF |
real(3) |
Translational spring values |
|
|
DFLRCO |
string(120) |
Default Floor Code |
|
|
DFLRHE |
real |
Default Floor Height |
|
|
DFLRTY |
string(120) |
Default Floor Type |
|
|
DFLT |
string(120) |
Default value for the attribute |
|
|
DFLTA |
string(1000) |
Defaults for Type 1 annotation - special attribute for use by ADP |
|
|
DFLTB |
string(1000) |
Defaults for Type 2 annotation - special attribute for use by ADP |
|
|
DFLTC |
string(1000) |
Defaults for Type 3 annotation - special attribute for use by ADP |
|
|
DFNM |
string(1024) |
Document filename |
|
|
DFON |
integer |
Dimension text font |
|
|
DFONTN |
string(80) |
Dimension text font name |
|
|
DFUN |
element |
Default unit |
|
|
DHTEST |
integer(500) |
Test locator expression |
|
|
DHTEXT |
integer(500) |
Default home identifier expression |
|
|
DIAM |
real |
Diameter |
|
|
DIAREF |
element(500) |
Diagram reference array for schematic elements |
|
|
DIME |
logical |
DRAFT user defined symbol dimension flag |
|
|
DIMPOS |
pos |
Derived 3D dimension position |
|
|
DIMTXT |
string(40) |
Dimensions text |
|
|
DINTER |
string(257) |
Default Interference class |
|
|
DINTHK |
real |
Default insulation thickness |
|
|
DIR |
dir |
Direction |
|
|
DIREV |
dir |
Direction evaluation |
|
|
DIRXP |
integer(500) |
Direction expression |
|
|
DISP |
real(3) |
Translation displacements |
|
|
DIST |
real(2) |
Distances |
|
|
DISTAG |
string(120) |
Display tag |
|
|
DISTFH |
real |
Distance from head |
|
|
DISTFN |
real |
Distance from next point |
|
|
DISTFP |
real |
Distance from previous point |
|
|
DISTM |
real(2) |
Distances to M1 and M2 curves |
|
|
DKEY |
word |
Data Key |
|
|
DLCOLO |
integer |
Dimension line colour |
|
|
DLCONU |
integer |
Dimension line colour number |
|
|
DLEV |
integer |
Drawing level |
|
|
DLFG |
string |
Linear/Angular dimension line flag |
|
|
DLIM |
real(6) |
Displacement limit |
|
|
DLIST |
word(2000) |
List of all possible dist att types |
|
|
DLPN |
integer |
Dimension line pen |
|
|
DLSTREF |
element |
Dimension linestyle Reference |
|
|
DLSTYL |
integer |
Dimension linestyle |
|
|
DMFA |
element(2) |
ISODRAFT Reference Dimension attribute |
|
|
DMFL |
real(9) |
Displacement moment flexibility |
|
|
DMSP |
real |
Lower limit to spacing between parallel dimensions |
|
|
DMTX |
string(1000) |
Dimension text |
|
|
DMTY |
word(2) |
ISODRAFT Reference Dimension attribute |
|
|
DNST |
real |
Density |
|
|
DOCREF |
element |
Document reference |
|
|
DOCXRF |
element(500) |
Return reference from Design element to DOCITM element |
|
|
DOFF |
real |
Dimension line offset |
|
|
DOFIL |
string(73) |
Drawing Object filename |
|
|
DPBO |
real |
integer |
Design point bore |
|
DPCO |
word |
integer |
Design point connection type |
|
DPCOU |
integer |
Number of valid design points |
|
|
DPDI |
dir |
integer |
Design point direction |
|
DPFN |
string(1024) |
ISODRAFT dynamic detail plotfile name |
|
|
DPGR |
real |
integer |
Design Point Gradient |
|
DPGRID |
integer |
ISODRAFT dynamic detail grid reference attribute |
|
|
DPLS |
integer(200) |
List of valid design points |
|
|
DPOS |
pos |
Dimension line/arc position |
|
|
DPPS |
pos |
integer |
Design point position |
|
DPREMA |
real |
Design pres. max |
|
|
DPREMI |
real |
Design pres. min |
|
|
DPRO |
string(1000) |
parameterized Property Expression (Default) |
|
|
DPSF |
element |
Design PPointset reference |
|
|
DPVI |
integer(200) |
List of visible design points |
|
|
DRAD |
string(1000) |
Radial offset |
|
|
DRAWNO |
string(26) |
Drawing number |
|
|
DREVAY |
element(50) |
DRWG revisions array |
|
|
DRFILE |
string(73) |
Drawing File name |
|
|
DRFNUM |
integer(11) |
Drawing file numbers |
|
|
DRFTYP |
integer(11) |
Drawing File Types |
|
|
DRGP |
integer |
Drawing priority (used to determine how to draw SCTN) |
|
|
DRMXTL |
integer |
Draft general max text length |
|
|
DRNE |
dir |
Plane normal at end of SCTN/GENSEC |
|
|
DRNS |
dir |
Plane normal at start of SCTN/GENSEC |
|
|
DRPS |
pos |
Derived position for steelwork |
|
|
DRRF |
element |
Old spooler drawing reference |
|
|
DRSSRE |
element |
Draft Symbol set reference |
|
|
DRTITL |
string(120) |
Drawing title |
|
|
DRTMPR |
element |
Draft template reference |
|
|
DRWGN |
string(1000) |
Drawing number |
|
|
DSCO |
string(120) |
Design code |
|
|
DSESS |
string(120) |
integer |
Date of specified session |
|
DSET |
logical(3) |
Displacement limits set flag - ignore values if FALSE |
|
|
DSGNTN |
string |
Designation |
|
|
DSTNCE |
real |
Distance |
|
|
DSTY |
string |
Radial dimension style flag |
|
|
DTAN |
string |
Dimension text angle flag |
|
|
DTCH |
real |
Dimension text character height |
|
|
DTCOLO |
integer |
Dimension text colour |
|
|
DTCONU |
integer |
Dimension text colour number |
|
|
DTER |
string |
Dimension terminator code |
|
|
DTFL |
string |
Dimension text radius flag |
|
|
DTIT |
string(32) |
Data Title |
|
|
DTLELE |
element(5000) |
Datal Elements list |
|
|
DTLH |
real |
Dimension text letter height |
|
|
DTLLIST |
word(2000) |
Datal Attributes List |
|
|
DTLTST |
integer(8192) |
Datal Test attribute |
|
|
DTMPMA |
real |
Design temp. max |
|
|
DTMPMI |
real |
Design temp. min |
|
|
DTOF |
real(2) |
Dimension text offset |
|
|
DTOP |
real |
Top diameter |
|
|
DTPN |
integer |
Dimension text pen |
|
|
DTRA |
real |
Dimension text radius |
|
|
DTRE |
element |
Data set reference |
|
|
DTUL |
string |
Dimension text underlining flag |
|
|
DTWTCL |
string |
Date of weight/cog calculation |
|
|
DTXR |
string(120) |
RTEXT of detailing text |
|
|
DTXS |
string(120) |
STEXT of detailing text |
|
|
DTXT |
string(120) |
TTEXT of detailing text |
|
|
DUCTHE |
real |
Default duct height |
|
|
DUCTSH |
word |
Default duct shape |
|
|
DUCTWI |
real |
Default duct width |
|
|
DUNI |
word |
Distance units |
|
|
DUNION |
integer |
DRAFT element union detail flag |
|
|
DUPLIC |
element(10000) |
integer |
Duplicates of the current element with the same attribute values |
|
DUTY |
string(120) |
Duty |
|
|
DVFL |
logical |
ADP detail views flag |
|
|
DVSCL |
real(500) |
ADP detail view allowable scale list |
|
|
DVTH |
real |
ADP detail views threshold |
|
|
DWALLT |
real |
Derive wall thickness |
|
|
DWID |
string(1000) |
Width offset |
|
|
DWINSI |
real |
Default Window Sill |
|
|
DX |
string(1000) |
Cartesian X offset |
|
|
DXL |
string(1000) |
Incremental X length |
|
|
DY |
string(1000) |
Cartesian Y offset |
|
|
DYL |
string(1000) |
Incremental Y length |
|
|
E |
real |
Position easting |
|
|
EASTING |
pos |
Easting part expressed as a position |
|
|
ECCE |
pos |
Eccentricity (steelwork) |
|
|
ECCJ |
pos |
Eccentricity of joint (steelwork) |
|
|
ECLASS |
word(100) |
Access Control Element class |
|
|
ECRFA |
element(500) |
Equipment connection reference array |
|
|
EDGELE |
real |
Edge Length |
|
|
EDISTA |
real |
Vertical Distance of End |
|
|
EDPUV |
pos |
End point |
|
|
EFAC |
string(1000) |
E-factor |
|
|
EFOR |
real(3) |
End force vector components |
|
|
ELCXRF |
element(500) |
Return reference from CABLE element to ELCONN element |
|
|
ELDATA |
integer(8192) |
data |
|
|
ELDSZ |
integer |
DataSize |
|
|
ELECRE |
logical |
integer |
True if created since given session |
|
ELECREC |
logical |
True if created since comparison date |
|
|
ELEDEL |
logical |
integer |
True if deleted since given session |
|
ELEDELC |
logical |
True if deleted since comparison date |
|
|
ELEL |
word(200) |
Types of elements (including UDETs) to which this attribute applies |
|
|
ELEMOD |
logical |
integer |
True if modified since given session |
|
ELEMODC |
logical |
True if modified since comparison date |
|
|
ELEPTR |
integer |
Elemp |
|
|
ELESZ |
integer |
Size |
|
|
ELEVAT |
real |
Elevation |
|
|
ELEVV |
logical |
Is Elevation View |
|
|
ELRATI |
real |
Electrical Rating |
|
|
ELTYPC |
word |
Element type |
|
|
ELVRSN |
integer |
Element version |
|
|
EMOM |
real(3) |
End moment components |
|
|
ENCODB |
string |
DB Encoding |
|
|
ENDA |
real |
End angle |
|
|
ENDELE |
real |
End Elevation |
|
|
ENDOFF |
real |
Offset of the end of section |
|
|
ENDPOINT |
integer |
Cable End connection point |
|
|
ENDPOS |
pos |
End Position |
|
|
ENDREF |
element |
Cable End reference |
|
|
EPARAM |
real(6) |
Evaluated parameters |
|
|
EPKDI |
real |
Proportional distance of end point along Pline |
|
|
EPOSTO |
real |
End post tangent offset |
|
|
EREC |
integer |
Erection class |
|
|
EREL |
integer |
End releases (packed) |
|
|
ETEX |
string(1000) |
Example text |
|
|
EVOL |
real(6) |
Enclosing box volume in given coordinates |
|
|
EXBTEX |
string(1500) |
Expanded annotation text |
|
|
EXCESS |
real |
Excess |
|
|
EXCLEN |
real(3) |
Length of excess intervals (type 1-3) |
|
|
EXCLFR |
logical |
True if element claimed from this extract. Only True for Primary elements |
|
|
EXCLFT |
real |
Excess on left side of seam |
|
|
EXCLHI |
element(5000) |
Primary elements in descendant hierarchy claimed to this extract (includes this element) |
|
|
EXCLPA |
logical |
True if element claimed to Parent extract. Only True for Primary elements |
|
|
EXCLTO |
logical |
True if element claimed to this extract. Only True for Primary elements |
|
|
EXCNUM |
int(3) |
Number of excess intervals (type 1-3) |
|
|
EXCRGT |
real |
Excess on right side of seam |
|
|
EXCTLF |
integer |
Excess type on left side of seam |
|
|
EXCTRG |
integer |
Excess type on right side of seam |
|
|
EXDMTX |
string(1500) |
Expanded dimension text |
|
|
EXECAFTER |
string(512) |
Exec file after DB propagation |
|
|
EXECBEFORE |
string(512) |
Exec file before DB propagation |
|
|
EXFI |
integer |
Extract file number |
|
|
EXHCNC |
element(5000) |
As EXTCNC, but repeat test for all descendants |
|
|
EXHCNN |
element(5000) |
As EXTCNN, but repeat test for all descendants |
|
|
EXHCON |
element(5000) |
As EXTCON, but repeat test for all descendants |
|
|
EXHRCN |
element(5000) |
As EXRCN, but repeat test for all descendants |
|
|
EXHRCO |
element(5000) |
As EXTRCO, but repeat test for all descendants |
|
|
EXMOC |
logical |
As EXMOD but ignoring changes to "noclaim" attributes and member lists |
|
|
EXMOD |
logical |
True if element modified in this extract |
|
|
EXNCLH |
element(5000) |
Primary elements in descendant hierarchy not claimed to this extract |
|
|
EXPA |
real |
Spot value of expansion coefficient |
|
|
EXPIRY |
string(50) |
Protected DB Expiry date |
|
|
EXPLTX |
string(1500) |
Expanded projection line text |
|
|
EXPMOC |
logical |
As EXPMOD but ignoring changes to "noclaim" attributes and member lists |
|
|
EXPMOD |
logical |
True if primary and element or non-primary descendants have been modified in this extract |
|
|
EXPRESSION |
string(4000) |
Expression |
|
|
EXPTYPE |
string(60) |
Expression type |
|
|
EXTALS |
element(8191) |
Extract ancestors |
|
|
EXTBOX |
real(6) |
Defined box |
|
|
EXTCLS |
element(8191) |
Extract children |
|
|
EXTCNC |
element(5000) |
As EXTCON but excluding non modified elements |
|
|
EXTCNN |
element(5000) |
As EXTCON but excluding modified elements |
|
|
EXTCON |
element(5000) |
Primary elements connected/disconnected from element or non primary descendants in extract |
|
|
EXTDES |
element(8191) |
Extract descendants |
|
|
EXTDIR |
string(10) |
Direction of ladder exit |
|
|
EXTFAM |
element(8191) |
Extract family |
|
|
EXTHI |
integer |
Location extract number range, high limit |
|
|
EXTLO |
integer |
Location extract number range, low limit |
|
|
EXTMAS |
element |
Extract master |
|
|
EXTNO |
integer |
Extract number |
|
|
EXTNSN |
real |
Extension |
|
|
EXTOWN |
element |
Extract owner |
|
|
EXTRC |
string(120) |
Name of extract claiming element |
|
|
EXTRCN |
element(5000) |
As EXTCNN, but applied recursively to each connection |
|
|
EXTRCO |
element(5000) |
As EXTCON, but applied recursively to each connection |
|
|
EXTREF |
element |
References to exit level |
|
|
EZDI |
real |
End load point in section |
|
|
FAAN |
integer |
Skew angle for font file |
|
|
FACODE |
string(100) |
Facode |
|
|
FAILCO |
integer |
FailCond |
|
|
FAREA |
string(5) |
Construction area |
|
|
FCDATE |
integer(2) |
File creation date |
|
|
FCENTRE |
pos |
Centre of fillet arc |
|
|
FCLXSP |
real(100) |
Spacing between stair flights in the X direction of the tower |
|
|
FCLYSP |
real(100) |
Spacing between stair flights in the Y direction of the tower |
|
|
FCMEAS |
real |
Flange correction measure |
|
|
FCODE |
string |
Face code |
|
|
FCOE |
real(3) |
Friction coefficient |
|
|
FCOLOUR |
integer |
Fill colour |
|
|
FCONUM |
integer |
Fill colour number |
|
|
FCPY |
element |
Forward copy reference |
|
|
FDEPD |
string(250) |
word |
Formatted Local Design Property Default Value |
|
FDEPR |
string(250) |
word |
Formatted Local Design Property Value |
|
FDRA |
string(32) |
Isometric drawing number |
|
|
FEDEXS |
real(500) |
Feed excess values |
|
|
FEMCOL |
integer |
FEM image object colour |
|
|
FEND |
pos |
Fillet arc position |
|
|
FEQDES |
string(120) |
From Equipment Description |
|
|
FFCOLO |
integer |
Front-face colour |
|
|
FFCONU |
integer |
Front-face colour number |
|
|
FFLEXT |
real |
Edge Extension Around Floor layer |
|
|
FFPN |
integer |
Front-face pen |
|
|
FFSTREF |
element |
Front-face linestyle Reference |
|
|
FFSTYL |
integer |
Front-face linestyle |
|
|
FGAP |
real |
First offset distance |
|
|
FGRF |
element(500) |
Reference to boundary faces |
|
|
FILCHK |
logical |
FILCHK (true if fill level check is enabled ) |
|
|
FILEEX |
logical |
True if DB file exists and is valid |
|
|
FILENAME |
string |
DB filename |
|
|
FILL |
logical |
DRAFT user defined symbol fill flag |
|
|
Fill level check |
logical |
Fill level check |
|
|
FILLDI |
word |
Fill direction |
|
|
FILREF |
element(500) |
Sorted references to attachment points with ascending order of fill level greater then 0 |
|
|
FILTOPERATOR |
string(20) |
Filter operator |
|
|
FILTVALUE |
string(1000) |
Filter value |
|
|
FINO |
integer |
File number |
|
|
FINPUT |
string(120) |
Input by |
|
|
FIRE |
real |
Fire resistance |
|
|
FIRERATING |
string(120) |
Fire rating |
|
|
FISSUE |
string(12) |
Current pipe spec issue |
|
|
FITLEN |
real |
Length of branch fitting |
|
|
FIXT |
string(12) |
Structural fixity |
|
|
FLALLO |
real |
Flange allowance |
|
|
FLATYP |
integer |
Flange type |
|
|
FLCARE |
real |
Floor cover area |
|
|
FLCSTHICKNESS |
real |
Floor cover thickness |
|
|
FLCVOL |
real |
Floor cover volume |
|
|
FLEN |
string(1024) |
External file name |
|
|
FLEVEL |
real |
Fill level at route node |
|
|
FLIM |
real(3) |
Force limit |
|
|
FLLARE |
real |
Floor layer area |
|
|
FLLTHK |
real |
Floor layer thickness |
|
|
FLLVOL |
real |
Floor layer volume |
|
|
FLNM |
string(700) |
Full name of the element |
|
|
FLNN |
string(700) |
Full name of the element (without leading slash) |
|
|
FLOFFS |
real |
Flange offset |
|
|
FLOW |
word |
Flow direction |
|
|
FLRCOD |
string(120) |
Floor Code |
|
|
FLRELE |
real |
Floor Elevation |
|
|
FLRELV |
real |
Floor elevation |
|
|
FLRHEI |
real |
Floor Height |
|
|
FLRTYP |
string(120) |
Floor Type |
|
|
FLTDIR |
dir |
Stairflight Direction |
|
|
FLUR |
element |
Fluid reference |
|
|
FLWA |
logical |
DRAFT user defined symbol flow arrow |
|
|
FMID |
pos |
Middle point of fillet arc |
|
|
FNAM |
string(1024) |
Filename |
|
|
FNCCD |
integer |
Functional description code |
|
|
FNCTXT |
string(80) |
Functional description |
|
|
FNMA |
string(32) |
Standard font file name |
|
|
FNMB |
string(32) |
Bold font file name |
|
|
FNTD |
string(32) |
Font directory |
|
|
FOLDED |
logical |
True if folded |
|
|
FONT |
integer |
Text font |
|
|
FONTN |
string(80) |
Font name |
|
|
FOOTRO |
real |
Clear space behind each rung |
|
|
FORC |
real(3) |
Force vector |
|
|
FOREIGN |
string |
DB foreign/local |
|
|
FPATH |
string(256) |
File path |
|
|
FPEN |
integer |
Fill pen |
|
|
FPLINE |
string(32) |
Process line number |
|
|
FPON |
integer |
FROM port number |
|
|
FPRDE |
string(250) |
word |
Formatted property default |
|
FPROP |
string(250) |
word |
Formatted property value from dataset |
|
FRAD |
real |
Fillet radius |
|
|
FRDR |
string(32) |
Reference drawings |
|
|
FREF |
element |
Fitting reference |
|
|
FREV |
string(4) |
Isometric drawing revision |
|
|
FRMSCL |
real |
Form scale |
|
|
FRPO |
pos |
Eye point |
|
|
FRSTW |
element |
word |
Reference of first world of given DB type in current MDB |
|
FSPOST |
real |
Distance to the first post |
|
|
FSTART |
pos |
Fillet start position |
|
|
FSTAT |
string(15) |
Fstatus |
|
|
FSTNUM |
integer |
Fill style number |
|
|
FSTREF |
element |
Fill style Reference |
|
|
FSTYLE |
integer |
Fill style |
|
|
FSTYNO |
integer |
Fill Style Number |
|
|
FTCDD |
string(250) |
word |
Formatted Current Design Property Default Value |
|
FTCDP |
string(250) |
word |
Formatted Current Design Property Value |
|
FTER |
string |
First dimension terminator code |
|
|
FTHICKNESS |
real |
Stair Flight Thickness |
|
|
FULLEN |
real |
Total length of manufactured profile |
|
|
FULLT |
string |
type of the element |
|
|
FULSYS |
string |
Type of the element, ignoring UDET, not truncated |
|
|
FUNC |
string(120) |
Function |
|
|
FUNI |
integer |
FUNIT |
|
|
FURNRF |
element |
Furniture Reference |
|
|
GANGLE |
real |
General Angle |
|
|
GAPALL |
string(1000) |
Gap Allowance |
|
|
GAPF |
real |
First offset distance |
|
|
GAPI |
real |
Intermediate offset distance |
|
|
GAPS |
real(30) |
Projection line gap array |
|
|
GAREA |
real |
Ceiling Grid Area |
|
|
GASTIG |
logical |
Gas Tight |
|
|
GATECO |
string(120) |
Gate Configuration |
|
|
GATESI |
real(2) |
Gate Size |
|
|
GBOX |
real |
Box gap |
|
|
GCOF |
pos |
Gross centre of gravity |
|
|
GDEFIN |
integer(100) |
Glyph Outline Definition |
|
|
GDIAM |
integer |
Glyph Circle Diameter |
|
|
GENGT |
word |
Geometry type |
|
|
GENSTR |
string |
General strings |
|
|
GENTYP |
word |
Type of geometry |
|
|
GEODEP |
element(5000) |
Direct geometrical dependencies |
|
|
GEOM |
integer |
Geometry Modified- Not directly queryable |
|
|
GFILLD |
logical |
Glyph Primitive Filled Flag |
|
|
GHEIGH |
real |
Gate Height |
|
|
GLBSTR |
logical |
True if Project has Global structure |
|
|
GLBVER |
string(120) |
Global version string |
|
|
GLYNO |
integer |
Glyph Number |
|
|
GLYNUM |
integer |
Glyph Number |
|
|
GLYREF |
element |
Glyph Reference |
|
|
GMOF |
real(9) |
Gross moments of inertia |
|
|
GMRE |
element |
Geometry set reference |
|
|
GOBREF |
element |
Generating reference |
|
|
GOFFS |
integer(2) |
Glyph Primitive offset |
|
|
GOING |
real(10) |
Tread Going |
|
|
GPPRXS |
element(500) |
Group proxy items referring to element |
|
|
GPSTR |
string |
General purpose strings |
|
|
GRADE |
real |
Steel grade |
|
|
GRAXE |
integer |
Grid axes (internal) |
|
|
GRDAXE |
string |
Grid axes |
|
|
GRDDIR |
dir |
Grid direction |
|
|
GRDE |
real |
Gradient of implied tube. Gradient is the vertical rise(fall) divided by the horizontal distance. |
|
|
GRDID |
string(20) |
Grid Identifier |
|
|
GRDLBL |
string(20) |
Grid Label |
|
|
GRDLID |
integer(2) |
Gridline Identifier |
|
|
GRDLXP |
real |
Proportion along X gridline from Gridline ID |
|
|
GRDLYP |
real |
Proportion along Y gridline from Gridline ID |
|
|
GRDOFF |
real |
Grid offset |
|
|
GRDPOS |
pos |
Grid Position |
|
|
GRDXSP |
real(10000) |
Grid X Spacing |
|
|
GRDYSP |
real(10000) |
Grid Y Spacing |
|
|
GRIDNM |
element |
Design grid reference |
|
|
GRIDNX |
string(120) |
Design element as text |
|
|
GRIND |
real |
Grinding info |
|
|
GRILEN |
real |
Length of grinding intervals |
|
|
GRINUM |
integer |
Number of grinding intervals |
|
|
GRIP |
real |
Minimum distance between bends |
|
|
GROUPS |
element(500) |
GPSETs in which element occurs |
|
|
GRPRF |
element |
Reference to group (owner of location) |
|
|
GRSYS |
element |
Grid system reference |
|
|
GSRF |
real |
Gross surface area |
|
|
GSTR |
element |
Structural geometry set reference |
|
|
GTAREAS |
element(5000) |
All areas that fully or partially enclose element |
|
|
GTEXAREAS |
element(5000) |
All areas that fully enclose element |
|
|
GTXT |
string(120) |
Text storing rule to generate Inventory List |
|
|
GTYP |
word |
Generic type |
|
|
GVOL |
real |
Gross volume |
|
|
GWEI |
real |
Gross weight |
|
|
GWIDTH |
real |
Gate Width |
|
|
GXLEN |
integer |
Glyph Rectangle XLength |
|
|
GXYOFF |
real(2) |
Grid XY Offset |
|
|
GYLEN |
integer |
Glyph Rectangle YLength |
|
|
HANGLE |
real |
Hatching Angle |
|
|
HAZARD |
string(120) |
Hazard |
|
|
HAZTYP |
string(120) |
Hazard Description |
|
|
HBLBOX |
real(6) |
Block box |
|
|
HBOR |
real |
Head bore |
|
|
HCCNT |
integer |
Header/Extract list changes count |
|
|
HCOFG |
pos |
computed hull item centre of gravity |
|
|
HCON |
word |
Head connection type |
|
|
HCORRO |
real |
Head Corrosion |
|
|
HCREF |
element(10) |
Head connections |
|
|
HDBREF |
element |
Generic Hull DB Ref |
|
|
HDCONN |
element(500) |
List of elements connected to branch head |
|
|
HDIR |
dir |
Head direction |
|
|
HDMF |
element(2) |
ISODRAFT Reference Dimension attribute |
|
|
HDMT |
word(2) |
ISODRAFT Reference Dimension attribute |
|
|
HDREF |
element(500) |
List of attachment connected to attachment |
|
|
HDUPLI |
element(10000) |
integer |
Duplicates of the current element (checking members) |
|
HEADCL |
real |
Head Clearance |
|
|
HEADRO |
real |
Headroom |
|
|
HEATT |
integer |
Heat Treatment |
|
|
HEIARR |
real(10) |
Height array |
|
|
HEID |
real |
Default Height value |
|
|
HEIF |
real |
Height attractor factor |
|
|
HEIG |
real |
Height |
|
|
HEIL |
real(2) |
Height limits (Min/Max) |
|
|
HEIS |
logical |
Height set flag - ignore Height values if FALSE |
|
|
HEND |
string |
Connection at other end of HREF (HEAD or TAIL) |
|
|
HGHT |
real |
Height |
|
|
HGSIDE |
word |
Hinge side |
|
|
HHBO |
real |
Hanger head bore |
|
|
HHBP |
pos |
Bottom of hanger head |
|
|
HHCO |
word |
Hanger head connection type |
|
|
HHDR |
dir |
Hanger head direction |
|
|
HHGR |
real |
Hanger head gradient |
|
|
HHOD |
real |
Hanger head outside diameter |
|
|
HHPO |
pos |
Hanger head position |
|
|
HHTP |
pos |
Top of hanger head |
|
|
HIERARCHY |
element(5000) |
Structural connections |
|
|
HIST |
integer(120) |
attr |
History of sessions in which element or specified attribute were made |
|
HLCOLO |
string |
Hull Colour |
|
|
HLIS |
word(2000) |
List of all possible types in owning hierarchy |
|
|
HLSTREF |
element |
Hatching linestyle Reference |
|
|
HLSTYLE |
integer |
Hatching linestyle |
|
|
HMAV |
real |
Average humidity |
|
|
HMMA |
real |
Maximum humidity |
|
|
HMMI |
real |
Minimum humidity |
|
|
HNCKEY |
integer |
Hole Notch Cutout Key |
|
|
HOFFSE |
real |
Hatching Line Offset |
|
|
HOFFT |
real |
Head offset |
|
|
HOLGRD |
logical |
True if any hole in the plate should be ground |
|
|
HPATNO |
integer |
Hatch Pattern Number |
|
|
HPOS |
pos |
Head position |
|
|
HPOSE |
real |
Easting of head position |
|
|
HPOSN |
real |
Northing of head position |
|
|
HPOSU |
real |
Upping of head position |
|
|
HPREF |
element |
Head point reference |
|
|
HREF |
element |
Head reference |
|
|
HREL |
logical |
Branch Member Head relative flag (Router) |
|
|
HRJUSL |
word |
Handrail Justification Line |
|
|
HRSF |
element |
Hatch ruleset reference |
|
|
HSARFA |
element(500) |
HVACSpool arrive references |
|
|
HSEPAR |
real |
Hatching Line Separation |
|
|
HSLRFA |
element(500) |
HVACSpool leave references |
|
|
HSPE |
element |
Hanger specification |
|
|
HSRFA |
real |
Computed Hull item surface area |
|
|
HSRO |
element |
Headrod specification |
|
|
HSTU |
element |
Head tube specification |
|
|
HSTYF |
element |
Hatch style reference |
|
|
HTBO |
real |
Hanger tail bore |
|
|
HTBP |
pos |
Bottom of hanger tail |
|
|
HTCO |
word |
Hanger tail connection type |
|
|
HTDR |
dir |
Hanger tail direction |
|
|
HTGR |
real |
Hanger tail gradient |
|
|
HTOD |
real |
Hanger tail outside diameter |
|
|
HTPO |
pos |
Hanger tail position |
|
|
HTPREF |
element |
Topology reference |
|
|
HTTP |
pos |
Top of hanger tail |
|
|
HTYP |
word |
Hanger type |
|
|
HUBRF |
element |
Reference to the hub location |
|
|
HULAPP |
logical |
Hull applicable Geometry |
|
|
HULCNT |
integer |
Size of hull array/collection |
|
|
HULLDE |
logical |
True if element is a hull design item |
|
|
HULLOB |
element |
Hull object reference |
|
|
HULLPR |
logical |
True if element is a hull production item |
|
|
HULOC |
string |
Location |
|
|
HUMIDI |
real |
Design Humidity |
|
|
HUMIRR |
logical |
True if mirrored in local v-axis |
|
|
HUMVW |
string |
Model View |
|
|
HUREFL |
logical |
Reflected |
|
|
HUREPL |
element |
Replica |
|
|
HUSYMM |
logical |
Symmetrical |
|
|
HVOLU |
real |
Computed Hull Item volume |
|
|
HWALLT |
real |
Head wall thickness |
|
|
HWEIG |
real |
computed analytic hull item weight |
|
|
HWRF |
element |
Head Working Point (Router) |
|
|
IBLNAM |
string |
Name of idealised block |
|
|
ICAT |
element |
Insulation catalogue reference |
|
|
ICLASS |
string(120) |
Interference class |
|
|
ICON |
string(120) |
ICON |
|
|
ICONL |
string(120) |
ICONL |
|
|
ICONN |
integer |
COMMS connection type (0/1 = on/off-line) |
|
|
ICONS |
string(120) |
ICONS |
|
|
ICOTYP |
string(300) |
Icon used for element |
|
|
IDENT |
string |
Panel identification string |
|
|
IDET |
element |
Insulation detail text reference |
|
|
IDLABL |
real |
Length of label idle movement |
|
|
IDLFAC |
real |
Idle movement factor |
|
|
IDLL |
real(3) |
Burning idle length |
|
|
IDLLEN |
real(2) |
Non-burning idle length |
|
|
IDLN |
element |
Drawlist name reference |
|
|
IDLX |
string(120) |
Drawlist name (as text) |
|
|
IDNM |
element |
Design data or catalogue component |
|
|
IDNX |
string(120) |
Design data or catalogue component (as text) |
|
|
IDRT |
string(2000) |
Insulation detail RTEXT |
|
|
IDSPU |
integer |
Specified unique identifier |
|
|
IDST |
string(2000) |
Insulation detail STEXT |
|
|
IDTT |
string(2000) |
Insulation detail TTEXT |
|
|
IGAP |
real |
Intermediate offset distance |
|
|
IGNDUN |
logical |
Ignore DUnion flag |
|
|
IMAT |
element |
Insulation material text reference |
|
|
IMGDAT |
integer(8192) |
Image data |
|
|
IMPED |
string(1000) |
Impedance |
|
|
IMXT |
string(2000) |
Insulation material XTEXT |
|
|
IMYT |
string(2000) |
Insulation material YTEXT |
|
|
IMZT |
string(2000) |
Insulation material ZTEXT |
|
|
INCBOR |
real |
Inch Nominal Bore |
|
|
INCL |
real |
Inclination angle |
|
|
INFA |
string(119) |
Client info - Project Name |
|
|
INFB |
string(119) |
Comment - Project Message |
|
|
INFG |
logical |
Insulation flag |
|
|
INFOTE |
string(120) |
Infotext |
|
|
INIVAL |
element |
Initial Value |
|
|
INMTRF |
element |
INSMAT Reference |
|
|
INPINDEN |
real |
Insulation pin density (Area) |
|
|
INPINLEN |
real |
Pin length |
|
|
INPINT |
string(120) |
Insulation pin type |
|
|
INPRTR |
element |
Inside paint reference |
|
|
INRE |
element |
Insulation reference |
|
|
INRF |
element |
Array of Inventory Items |
|
|
INSARE |
real |
Insulation requirement area |
|
|
INSC |
string(120) |
Inspection schedule |
|
|
INSL |
logical |
DRAFT user defined symbol insulation flag |
|
|
INSTNC |
string |
Bracket instance name |
|
|
INSTOPTIONS |
string(120) |
Installation Options |
|
|
INSURE |
element |
Reference to a INSCMP element |
|
|
INSUTY |
string(120) |
Insulation type |
|
|
INSYST |
element(500) |
Reference Array of all SYSGRPs Elements |
|
|
INTHK |
real |
Insulation thickness |
|
|
INTSEN |
logical |
Installation Sense - true if clockwise |
|
|
INTY |
word |
Inventory item type |
|
|
INVF |
element(500) |
Array of Inventory Items |
|
|
INVI |
logical(500) |
Visibility state |
|
|
IPAR |
real(30) |
Parameters of the insulation catalogue component |
|
|
IPRE |
real |
Internal pressure |
|
|
IRNO |
string |
ISO-IR number |
|
|
ISCOPY |
logical |
True if a copy DB |
|
|
ISDBFR |
logical |
True if database is foreign |
|
|
ISDBPR |
logical |
True if database is primary for global working |
|
|
ISDRDB |
logical |
True if database has drawings |
|
|
ISECPT |
pos |
Intersection point |
|
|
ISEXAP |
logical |
True if extract ancestry is primary here |
|
|
ISEXCP |
logical |
True if all extract children are primary here |
|
|
ISEXMP |
logical |
True if extract master is primary here |
|
|
ISEXOP |
logical |
True if extract owner is primary here |
|
|
ISEXTR |
logical |
True if an extract |
|
|
ISFOR |
logical |
True if database is foreign |
|
|
ISKEYDB |
logical |
Does ukey incorporate DB number |
|
|
ISLOADED |
logical |
True if Sheet is loaded |
|
|
ISMAST |
logical |
True if a Master DB, that is top level extract |
|
|
ISNAMED |
logical |
True if element is named |
|
|
ISOHIDDEN |
logical |
Isohidden flag |
|
|
ISPE |
element |
Insulation spec reference |
|
|
ISPICF |
logical |
Picture has File |
|
|
ISPR |
element |
Insulation specification component reference |
|
|
ISPRIM |
logical |
True if database is primary at this location |
|
|
ISSUE |
logical |
True if drawing has been issued |
|
|
ISWORK |
logical |
True if a working extract |
|
|
ITLE |
real |
Length of implied tube |
|
|
ITMTBL |
integer(2000) |
Table linking AITEMS elements to piping components |
|
|
ITPS |
pos |
Position of implied tube |
|
|
IWDORF |
element(1500) |
Weld owners attribute on IWELD elements |
|
|
IWDOWN |
integer(8) |
Table linking IWELD elements to piping components |
|
|
JFRE |
logical |
True if Section position dominates a connection |
|
|
JLIN |
word |
Joining line |
|
|
JLNE |
word |
Joining line end |
|
|
JLNS |
word |
Joining line start |
|
|
JMAX |
integer |
Maximum joint number in current spool drawing |
|
|
JNTBEV |
real(2) |
Joint part bevel code |
|
|
JNTC |
integer |
Joint Code |
|
|
JNTCOM |
string(300) |
Welded joint comment |
|
|
JNTNAM |
string(26) |
Welded joint name |
|
|
JNTNUMBER |
integer |
Joint number |
|
|
JNTORF |
element(1500) |
Joint owners attribute on IJOINT elements |
|
|
JNTOWN |
integer(8) |
Table linking IJOINT elements to piping components |
|
|
JNTREF |
element |
integer |
Return reference from Ppoint to ijoint element |
|
JNTTHK |
real(2) |
Joint part thickness |
|
|
JNTTSL |
real |
Total welded joint suspension length |
|
|
JNTTWL |
real |
Total welded joint length |
|
|
JNTTYP |
string(26) |
Welded joint type |
|
|
JNUM |
integer(2) |
Old spooler joint number |
|
|
JOIE |
element |
End joint |
|
|
JOIP |
word(2) |
Old spooler joint number prefix |
|
|
JOIS |
element |
Start joint |
|
|
JUSL |
word |
Justification Pline |
|
|
JUST |
string |
Justification |
|
|
KNUANG |
real |
Knuckle angle |
|
|
KNUCKL |
logical |
True if knuckled |
|
|
LABOFFS |
real(3) |
Label offset |
|
|
LABPOS |
pos |
Label position |
|
|
LABST |
integer |
Number of starts for label signing |
|
|
LACR |
logical |
Access Control on/off switch |
|
|
LACTIV |
logical |
True if selectable : false = limbospec |
|
|
LALCAB |
element(500) |
List arriving leaving cables on attached point |
|
|
LALLAN |
real |
Leave Ppoint allowed angle |
|
|
LASTM |
string(120) |
attr |
Date of last modification |
|
LAUTHU |
logical |
Login Authentication on/off switch |
|
|
LAXE |
ori |
Local axes |
|
|
LAYARF |
element |
Annotation Layer ruleset reference |
|
|
LAYDRF |
element |
Design Layer ruleset reference |
|
|
LAYTBF |
element |
Layer Table reference |
|
|
LBBORE |
logical |
TRUE if Minor/Branch bore is in nominal bore table |
|
|
LBOP |
pos |
Bottom of leave pipe |
|
|
LBOR |
real |
Leave bore |
|
|
LCAS |
integer |
Load case number |
|
|
LCHA |
logical |
Chain flag |
|
|
LCIRCR |
real(8) |
Least circumscribed rectangle |
|
|
LCKPSW |
logical |
Lock passwords for general users |
|
|
LCLAIM |
logical |
Access Control Claim flag |
|
|
LCLM |
logical |
True if element is claimed |
|
|
LCLMH |
logical |
True if element and hierarchy claimed |
|
|
LCNFA |
element(500) |
Array of elements with local names |
|
|
LCON |
word |
Leave connection type |
|
|
LCORRO |
real |
Leave corrosion allowance |
|
|
LCPOVWRITE |
logical |
Location Overwrite DB Users policy flag |
|
|
LCTROL |
logical |
Controlled DB Flag |
|
|
LCUTDI |
dir |
Lower Extension Cutting Direction |
|
|
LDFLT |
logical |
logical default value for a UDA |
|
|
LDI |
dir |
Leave direction |
|
|
LDISP |
logical |
Display property flag for design datasets: True if property is shown on form |
|
|
LDPR |
real |
word |
Local design dataset property |
|
LDRDIR |
dir |
Ladder Direction |
|
|
LEAFS |
real |
Number of door leafs |
|
|
LEAHEI |
real |
Leave height |
|
|
LEAV |
integer |
Leave Ppoint |
|
|
LEAWID |
real |
Leave width |
|
|
LEND |
logical |
Line end |
|
|
LENDTI |
integer |
Time out period for commands |
|
|
LENG |
real |
Length |
|
|
LENSEG |
real |
Length of segment |
|
|
LETTER |
string(120) |
Letter |
|
|
LEVE |
integer(2) |
Drawing level |
|
|
LEVENL |
integer |
Time interval for Event Loop |
|
|
LEVRFA |
element(500) |
References to levels serviced by stairwell |
|
|
LEXTNS |
real |
Lower Extension Length |
|
|
LFADIR |
dir |
Flight A Direction |
|
|
LFAOFFSET |
real |
Landing Flight A Offset |
|
|
LFBDIR |
dir |
Landing Flight B Direction |
|
|
LFBOFFSET |
real |
Landing Flight B Offset |
|
|
LFCOLO |
integer |
Label frame colour |
|
|
LFCONU |
integer |
Label frame colour number |
|
|
LFDP |
element |
word |
Local design dataset property |
|
LFPN |
integer |
Label frame pen |
|
|
LFRA |
logical |
Frame flag |
|
|
LFSTREF |
element |
Label frame linestyle Reference |
|
|
LFSTYL |
integer |
Label frame linestyle |
|
|
LGAP |
real |
Last offset distance |
|
|
LGOING |
real(10) |
Lower Tread Going |
|
|
LGRD |
real |
Leave Ppoint gradient |
|
|
LHBORE |
logical |
TRUE if Major/Header bore is in nominal bore table |
|
|
LHEA |
logical |
Logical head flag |
|
|
LHEI |
real |
Letter height |
|
|
LHIDE |
logical |
Hide flag for catalogue datasets: True if property is not shown on form |
|
|
LIGHTI |
real |
Lighting requirements |
|
|
LIMI |
real(6) |
Volume of interest |
|
|
LIMNUM |
integer |
Order number of limit |
|
|
LINIT |
logical |
Location initialization flag |
|
|
LINKRE |
element |
Link reference |
|
|
LINKS |
element(5000) |
Linked elements |
|
|
LINKSN |
integer |
Linked session on parent extract |
|
|
LINKXR |
element(1000) |
Referencing elements |
|
|
LISS |
logical |
True if drawing has been issued |
|
|
LIST |
word(2000) |
List of all possible member types |
|
|
LLCL |
real |
Leader line clearance |
|
|
LLCOLO |
integer |
Label leader colour |
|
|
LLCONU |
integer |
Label leader colour number |
|
|
LLDIAGRAMS |
string(2000) |
Line list diagrams |
|
|
LLEA |
logical |
Leader line flag |
|
|
LLENG |
real |
Leave length |
|
|
LLENTRY |
logical |
Is a line list entry - true or false |
|
|
LLFROM |
string(2000) |
From column text for a line list |
|
|
LLIS |
word(2000) |
List of all possible types in member hierarchy |
|
|
LLPN |
integer |
Label leader pen |
|
|
LLSTREF |
element |
Label leader linestyle Reference |
|
|
LLSTYL |
integer |
Label leader linestyle |
|
|
LLTBRANCH |
element |
Line list tail branch |
|
|
LLTO |
string(2000) |
To column text for a line list |
|
|
LMAXTR |
integer |
Maximum number of retries for command |
|
|
LMERDL |
logical |
PDMS GLOBAL Enable automatic merge of transaction db |
|
|
LMERFAILURE |
integer |
Number of days Failed commands persist in Trans dB |
|
|
LMERSUCCESS |
integer |
Number of days Successful commands persist in Trans dB |
|
|
LMERTI |
string(120) |
Frequency of Auto Merge of Transaction DB |
|
|
LMIRR |
logical |
True if Mirroring required |
|
|
LNAME |
string(20) |
Local name as stored on template |
|
|
LNDLEV |
real(100) |
Landing levels from owning element |
|
|
LNFA |
element(480) |
Hidden Reference Array for linked Vertices |
|
|
LNKCLS |
element(500) |
Classes referencing a DocLink |
|
|
LNKDOC |
element(500) |
DocLinks referring to element |
|
|
LNKELE |
element(500) |
Elements referencing a DocLink |
|
|
LNKPRP |
word |
TRUE if item pointed to by descriptor should be propagated by Global |
|
|
LNKREF |
element |
Reference internal document (drawing/sheet) |
|
|
LNKRX |
element |
Reference to first location of a link |
|
|
LNKRY |
element |
Reference to second location of a link |
|
|
LNKUSE |
word |
Link Descriptor Usage |
|
|
LNKWV |
integer |
Link weighting value |
|
|
LNLST |
string(2000) |
List of local names for current template |
|
|
LNOUPDATE |
logical |
DB propagation suppressed flag |
|
|
LNPRXS |
element(500) |
Proxy items referring to element |
|
|
LNTP |
word |
Line type |
|
|
LOCA |
string(120) |
Location |
|
|
LOCID |
string(3) |
Location identifier |
|
|
LOCK |
logical |
True if element is locked |
|
|
LOCPR |
element(1000) |
List of LOCs Primary at location |
|
|
LOCRF |
element |
Location reference |
|
|
LOCTYP |
integer |
Location |
|
|
LOD |
real |
Leave Ppoint outside diameter |
|
|
LOFF |
logical |
Offline flag |
|
|
LOGEV |
logical |
Logical value evaluation |
|
|
LOGFN |
string(1024) |
COMMS log file name |
|
|
LOGLV |
integer |
COMMS log file level of detail |
|
|
LOGMS |
logical |
COMMS log file active/inactive flag |
|
|
LOGXP |
integer(500) |
Logical expression |
|
|
LOHE |
real |
PLOOP height - from first PLOOP in owning panel |
|
|
LOOS |
logical |
Loose |
|
|
LOWGAP |
real |
Lower Gap |
|
|
LOWPOS |
pos |
Point nearest workshop floor |
|
|
LOWREF |
element |
References to lower exit level |
|
|
LPOS |
pos |
Leave position |
|
|
LPOSE |
real |
Easting of leave position |
|
|
LPOSN |
real |
Northing of leave position |
|
|
LPOSU |
real |
Upping of leave position |
|
|
LPROT |
logical |
Protected DB Flag |
|
|
LQAANG |
real |
Angle between alignment direction of leave Ppoint and next |
|
|
LQANG |
real |
Angle between leave Ppoint and next component |
|
|
LQBORE |
logical |
TRUE if leave Ppoint has same bore as next |
|
|
LQCON |
logical |
TRUE if leave Ppoint has Correct connection type |
|
|
LQOFF |
real |
Offset between leave Ppoint and next component |
|
|
LRBORE |
logical |
TRUE if bores is in reducer table |
|
|
LREF |
element |
Link reference |
|
|
LREFO |
logical |
Database holds Reference data only flag |
|
|
LRISE |
real |
Lower Tread Rise |
|
|
LSELEC |
logical |
True if can be set Directly in Design |
|
|
LSHA |
string |
Leader shape code |
|
|
LSPA |
real |
Text line spacing factor |
|
|
LSRO |
element |
Leave rod specification |
|
|
LSTR |
logical |
Stress flag |
|
|
LSTU |
element |
Leave tube reference |
|
|
LSTYNO |
integer |
Line Style Number |
|
|
LSWID |
real |
Line Style Width |
|
|
LSWKEY |
string(120) |
Line Style Width Key |
|
|
LTAI |
logical |
Logical tail flag |
|
|
LTBORE |
logical |
TRUE if bores is in branch (tee) table |
|
|
LTCORR |
real |
Leave tube corrosion allowance |
|
|
LTER |
string |
Label terminator code |
|
|
LTHICK |
real |
Door leaf thickness |
|
|
LTIMEI |
integer |
Time Interval between retries |
|
|
LTLE |
real |
Length of leave implied tube |
|
|
LTOP |
pos |
Top of leave pipe |
|
|
LTWALL |
real |
Leave tube wall thickness |
|
|
LTWREF |
element |
Leave tube wall thickness reference |
|
|
LVAR |
logical |
Variant Flag |
|
|
LVIS |
logical |
Visibility flag |
|
|
LVOL |
real(6) |
Enclosing box volume in local coordinates |
|
|
LWAITD |
integer |
Time interval between re-sending commands |
|
|
LWALLT |
real |
Leave wall thickness |
|
|
LWIDTH |
real |
Line Width |
|
|
LWP |
pos |
Lower Working Point |
|
|
LYCOL |
integer |
AutoCAD Layer Colour |
|
|
LYCVFR |
logical |
AutoCAD Layer Current Viewport Freeze |
|
|
LYDIR |
dir |
Leave Y axis direction on point |
|
|
LYFRZE |
logical |
AutoCAD Layer Freeze flag |
|
|
LYLOCK |
logical |
AutoCAD Layer Lock flag |
|
|
LYLTYP |
string(120) |
AutoCAD Layer LineType |
|
|
LYLWT |
real |
AutoCAD Layer LineWeight |
|
|
LYNVFR |
logical |
AutoCAD Layer New Viewport Freeze |
|
|
LYPFG |
logical |
AutoCAD Layer Plotting flag |
|
|
LYPSTY |
string(120) |
AutoCAD Layer Plotter Style |
|
|
LYVIS |
logical |
AutoCAD Layer Visibility Flag |
|
|
LZDIR |
dir |
Leave alignment direction |
|
|
MACRID |
string |
Clip macro ID |
|
|
MAINTENANCE |
real |
Maintenance level radiation |
|
|
MAKER |
string(100) |
Maker |
|
|
MANBLK |
string |
Name of owner block |
|
|
MANCOG |
pos |
Center of gravity |
|
|
MANLEN |
real |
Length of manual intervals |
|
|
MANNUM |
integer |
Number of manual intervals |
|
|
MANPAN |
string |
Name of owner panel |
|
|
MANTRA |
real(16) |
Transformation from local coordinate system |
|
|
MANTYP |
string(26) |
Manufactured type, for example. Plane, Curved,... |
|
|
MANU |
string(120) |
Manufacturer Name |
|
|
MANWGH |
real |
Weight |
|
|
MARKRF |
element(100) |
Cable Mark points |
|
|
MARPTY |
integer |
Marine picture type |
|
|
MATANG |
real |
Material Lay Angle |
|
|
MATDEN |
real |
Material density |
|
|
MATDIR |
dir |
Material direction |
|
|
MATID |
integer |
Material ID |
|
|
MATLEN |
real |
Material Length |
|
|
MATN |
string(1000) |
Material Note |
|
|
MATOVE |
real |
Material Overlap |
|
|
MATPURPOSE |
word |
Material purpose |
|
|
MATR |
element |
Material reference |
|
|
MATWID |
real |
Material Width |
|
|
MATX |
element |
Material text |
|
|
MAXA |
real |
Maximum answer |
|
|
MAXARE |
real |
Maximum area |
|
|
MAXB |
real |
Maximum bore |
|
|
MAXD |
integer |
DB hierarchy depth of lowest level item beneath element |
|
|
MAXFIL |
real |
Maximum percentage fill level |
|
|
MAXHUM |
real |
Maximum Humidity |
|
|
MAXLP |
real |
Maximum length of pipe |
|
|
MAXMIN |
real(2) |
Maximum and minimum values of design property |
|
|
MAXOD |
real |
Maximum Outer Diameter |
|
|
MAXPLN |
pos |
Maximum Plane Position |
|
|
MAXPRE |
real |
Maximum Pressure |
|
|
MAXREP |
integer |
Maximum number of Repeat items created |
|
|
MAXSLO |
real |
Maximum pipe slope |
|
|
MAXTEM |
real |
Maximum Temperature |
|
|
MAXU |
integer |
Maximum number of user |
|
|
MAXVOL |
real |
Maximum Volume |
|
|
MAXWAT |
real |
Maximum Water Level |
|
|
MBACK |
element(10000) |
elemtype |
Members in reverse order |
|
MBUFS |
integer |
Preferred buffer size in MBytes |
|
|
MCBENT |
logical |
Machine bent |
|
|
MCOLOUR |
integer |
Marker colour |
|
|
MCONUM |
integer |
Marker colour number |
|
|
MCOU |
integer |
elemtype |
Number of Element Members of Given type |
|
MDBCLS |
element(1000) |
List of MDBs in which DB is current |
|
|
MDBLS |
element(1000) |
List of MDBs to which DB belongs |
|
|
MDSYSF |
element(10) |
Reference Array of Model and Design Elements |
|
|
MELRFA |
element(500) |
All components (non-tube) in the PipePiece |
|
|
MEMB |
element(10000) |
elemtype |
All members, or members of specific type |
|
MEMDAB |
element(10000) |
Dabacon members |
|
|
MEML |
word |
Member line for SCTNs |
|
|
MEMNAM |
string(120) |
Member name |
|
|
MEMTYP |
string(256) |
Member type array |
|
|
MFAR |
word(50) |
Model Function Word array |
|
|
MFFIND |
element |
Find Manufacturingpackage folder |
|
|
MFLG |
logical |
Master link flag - SLAVE if FALSE |
|
|
MIDP |
pos |
Section midpoint (steelwork) |
|
|
MINARE |
real |
Minimum area |
|
|
MINBEN |
string(1000) |
Minimum Bend Radius |
|
|
MINFED |
real(500) |
Minimum feed values |
|
|
MINFIL |
real |
Min Fill level on Cableway and Cabletray components |
|
|
MINHUM |
real |
Minimum Humidity |
|
|
MINLP |
real |
Minimum length of pipe |
|
|
MINOD |
real |
Minimum Outer Diameter |
|
|
MINPLN |
pos |
Minimum Plane Position |
|
|
MINPOS |
integer |
Smallest position number of nested plate parts |
|
|
MINPRE |
real |
Minimum Pressure |
|
|
MINSLO |
real |
Minimum pipe slope |
|
|
MINTEM |
real |
Minimum Temperature |
|
|
MINVER |
real |
Minimum vertical pipe slope |
|
|
MINVOL |
real |
Minimum Volume |
|
|
MIRROR |
logical |
True if mirrored in local v-axis |
|
|
MLEF |
real |
Minimum length excluding flange |
|
|
MLIF |
real |
Minimum length including flange |
|
|
MLIM |
real(3) |
Moment limits |
|
|
MLNCOL |
integer |
Member-line colour |
|
|
MLNCON |
integer |
Member-line colour number |
|
|
MLNP |
integer |
Member line pen |
|
|
MLNSTREF |
element |
Member-line linestyle Reference |
|
|
MLNSTY |
integer |
Member-line linestyle |
|
|
MMBOR |
real |
MM Nominal Bore |
|
|
MODATT |
logical |
attr |
True if attribute of element can be modified |
|
MODDEL |
logical |
attr |
True if element can be deleted |
|
MODERR |
string(120) |
attr |
Returns the error text that would occur if attribute was modified |
|
MODID |
string(2000) |
LMI Model ID |
|
|
MODREF |
element |
Model reference |
|
|
MODU |
string(120) |
Module |
|
|
MOFI |
pos |
Moment of Inertia |
|
|
MOME |
real(3) |
Moment |
|
|
MOULEN |
real |
Mould length |
|
|
MPEN |
integer |
Marker pen |
|
|
MPFIND |
element |
Find Manufacturingpackage |
|
|
MPKGFD |
element |
Find Manufacturingpackage |
|
|
MPKGFI |
integer(500) |
Manufacturing Package Filter Expression |
|
|
MPKGRF |
element |
Manufacturing Package Reference |
|
|
MRGF |
logical |
ADP merge flag |
|
|
MRGL |
word |
ADP merge level |
|
|
MRKLEN |
real |
Total marking length |
|
|
MRKR |
word |
3 way component marker |
|
|
MRKST |
integer |
Number of starts for marking |
|
|
MSESS |
integer |
attr |
Last session number |
|
MSTREF |
element |
Marker style Reference |
|
|
MSTYLE |
integer |
Marker style |
|
|
MTBE |
element |
Material tube start. The first component, excluding ATTSs, for whom the LOFF is invalid or false |
|
|
MTCL |
real |
Material tube centreline length. |
|
|
MTEN |
element |
Material tube end. The first component, excluding ATTSs, for whom the LOFF is invalid or false |
|
|
MTLE |
real |
Material tube length for TUBI. Includes preceding bend length if bend is offline. |
|
|
MTOC |
word |
Material list control for components |
|
|
MTOH |
word |
Material list control for head tube |
|
|
MTOL |
string(1000) |
Material List Length |
|
|
MTOPARTNUMBERS |
integer(20) |
Additional spooling item part numbers |
|
|
MTOQ |
string(1000) |
Material take off quantity |
|
|
MTOR |
element(20) |
Extra material list spec references |
|
|
MTOT |
word |
Material list control for components leave tube |
|
|
MTOX |
integer(20) |
Old spooler addition items |
|
|
MTXR |
element |
Material text reference |
|
|
MTXX |
string(2000) |
XTEXT of material text |
|
|
MTXY |
string(2000) |
YTEXT of material text |
|
|
MTXZ |
string(2000) |
ZTEXT of material text |
|
|
MULT |
real |
Multiplier factor (unit definition) |
|
|
MVER |
element |
Reference to Master Vertex |
|
|
MYINSF |
element |
Surface Treatment Reference |
|
|
MYOUSF |
element |
Surface Treatment Reference |
|
|
MYSRFT |
element |
word |
Surface Treatment Reference |
|
N |
real |
Position northing |
|
|
NACCNT |
integer |
Non-additive changes count |
|
|
NAME |
string(500) |
Name of the element |
|
|
NAMEDB |
string |
DB name |
|
|
NAMESQ |
string(700) |
Type. sequence number and name of element |
|
|
NAMETY |
string(700) |
Type and name of the element |
|
|
NAMN |
string(500) |
Name of the element (without leading slash) |
|
|
NAMTYP |
string(700) |
Type and full name of element |
|
|
NANGLE |
real |
North angle |
|
|
NARE |
element |
Reference to neutral axis |
|
|
NBEVIT |
real(2) |
Pathtime except starts, I-bevel |
|
|
NBEVXT |
real(2) |
Pathtime except starts, X-bevel |
|
|
NBEVYT |
real(2) |
Pathtime except starts, Y-bevel |
|
|
NBORE |
real |
Allowable Nominal Bore |
|
|
NCHAR |
integer |
Number of label characters |
|
|
NCOF |
pos |
Nett centre of gravity |
|
|
NCOL |
integer |
Number of columns |
|
|
NCONNE |
integer |
Mismatched connections. that is no valid backpointer |
|
|
NCUTNT |
integer |
Number of cutouts and notches |
|
|
NCUTS |
integer |
Number of cuts in a miterd bend |
|
|
NDFLT |
real |
Numeric default value for a UDA |
|
|
NDTINT |
integer(2) |
NC tape date |
|
|
NDTTXT |
string(22) |
NC tape date text |
|
|
NGMR |
element |
Negative geometry set reference |
|
|
NGSD |
integer |
Number of GSDs |
|
|
NHOLE |
integer |
Number of holes |
|
|
NIDLAB |
real |
Pathtime except idle time for label |
|
|
NIDLT |
real(2) |
Pathtime except idle time |
|
|
NLCOLO |
integer |
Note colour |
|
|
NLCONU |
integer |
Note colour number |
|
|
NLOA |
real |
Nominal load |
|
|
NLPN |
integer |
Note/framing pen |
|
|
NLSTREF |
element |
Note linestyle Reference |
|
|
NLSTRT |
integer |
Number of label starts |
|
|
NLSTYL |
integer |
Note linestyle |
|
|
NMOF |
real(9) |
Nett moments of inertia |
|
|
NOCLIP |
logical |
View no clipping flag |
|
|
NOCOL |
integer |
Number of pin jig columns |
|
|
NODIMS |
logical |
No Dims Flag |
|
|
NOEXTCREATION |
logical |
Location extract create suppression flag |
|
|
NOFF |
integer |
Number off |
|
|
NOFG |
logical |
Link constraint inversion flag |
|
|
NOHLRF |
logical |
NoHLRFlag |
|
|
NOISEC |
string(104) |
Noise category |
|
|
NOMARK |
logical |
True if unmarked |
|
|
NOMBIN |
real(200) |
word |
List of valid Nominal bores in Inches |
|
NOMBMM |
real(200) |
word |
List of valid Nominal bores in MM |
|
NOMREF |
element |
Nominal bore table reference |
|
|
NOMXRF |
element(500) |
Return reference from NOMTAB element to SPECs |
|
|
NOPGS |
integer |
Number of openings |
|
|
NORM |
dir |
Plane normal |
|
|
NOROW |
integer |
Number of pin jig rows |
|
|
NORTHING |
pos |
Northing part expressed as a position |
|
|
NOSOFF |
real |
Nosing Offset |
|
|
NOTF |
element |
Cross-reference to NOTE/VNOT/SYTM |
|
|
NOTREAD |
integer(10) |
Number of treads |
|
|
NPDESC |
element(5000) |
List of non primary offspring |
|
|
NPILL |
integer |
Number of jig pillars |
|
|
NPLDFA |
string(80) |
Nesting default file 1 |
|
|
NPLDFB |
string(80) |
Nesting default file 2 |
|
|
NPLIST |
element(500) |
All NATPs attached to route node |
|
|
NPLMIR |
integer |
Quantity mirrored nested plates |
|
|
NPLNOR |
integer |
Quantity normal nested plates |
|
|
NPLTOT |
integer |
Total quantity nested plates |
|
|
NPOS |
pos |
Position in owner |
|
|
NPOSE |
real |
Easting of position wrt owner |
|
|
NPOSN |
real |
Northing of position wrt owner |
|
|
NPOSU |
real |
Upping of position wrt owner |
|
|
NPPT |
integer |
Ppoint number |
|
|
NPRSID |
string(26) |
Side of nested profile |
|
|
NPRVEC |
real(2) |
Local rotation vector of part |
|
|
NPSIDE |
string(80) |
Side of nested part |
|
|
NPXYP |
real(2) |
Local position of part |
|
|
NREL |
integer |
Nodal releases |
|
|
NROW |
integer |
Number of rows |
|
|
NRPARM |
integer |
Number of rest plate parameters |
|
|
NRULEE |
integer |
Number of rule inconsistencies on element |
|
|
NSIZ |
real |
Nominal size |
|
|
NSPE |
element |
Specification for NOZZLE |
|
|
NSRF |
real |
Nett surface area |
|
|
NSTART |
integer(2) |
Number of non-burning starts |
|
|
NSTD |
element |
Non-standard bolt length (reference to DTAB) |
|
|
NSTFAC |
real |
Number of starts - factor |
|
|
NSTRT |
integer(3) |
Number of burning starts |
|
|
NSTRTI |
integer(2) |
Number of burning starts I-bevel |
|
|
NSTRTX |
integer(2) |
Number of burning starts X-bevel |
|
|
NSTRTY |
integer(2) |
Number of burning starts Y-bevel |
|
|
NTEXT |
string(12) |
Null text |
|
|
NTRLEN |
real |
Neutral length |
|
|
NUCDNA |
real |
Distance to nearest anchor |
|
|
NUCDNE |
real |
Distance to the Nearest Edge |
|
|
NUCDNR |
element(2) |
Nearest Adjacent Anchor |
|
|
NUMB |
integer |
Number |
|
|
NUMBDB |
integer |
DB number |
|
|
NUMCOR |
integer |
Number of cores in a cable |
|
|
NUMOFF |
integer |
Number of Sheets in Drawing |
|
|
NUSED |
integer |
Number of used raw plates |
|
|
NVIEWF |
string(73) |
integer |
Neutral viewer filename |
|
NVOL |
real |
Nett volume |
|
|
NWEI |
real |
Nett weight |
|
|
NWELDS |
integer |
Number of attached welds on a piping component |
|
|
NXTDBN |
integer |
Next DB number |
|
|
NXTDBU |
integer |
Next Unique DB number |
|
|
NXTEXN |
integer |
Next DB extract number |
|
|
NXTFDB |
integer |
Next DB file and DB number |
|
|
NXTFLN |
integer |
Next DB file number |
|
|
NXTHB |
element |
Reference to next (future) hub |
|
|
NXTKEY |
integer |
next UDA/UDET key |
|
|
OANG |
real |
Overlay sheet angle |
|
|
OBCOLO |
integer |
Obscured face colour |
|
|
OBCONU |
integer |
Obscured face colour number |
|
|
OBFG |
logical |
Obstruction flag |
|
|
OBJCD |
integer(2) |
Object codes |
|
|
OBPN |
integer |
Obscured face pen |
|
|
OBST |
integer |
Obstruction level |
|
|
OBSTREF |
element |
Obscured face linestyle Reference |
|
|
OBSTYL |
integer |
Obscured face linestyle |
|
|
OCCTYP |
string(50) |
Occupancy Type |
|
|
OCCUPA |
real |
Occupancy |
|
|
OCOD |
string |
Hashed origin code |
|
|
OCONE |
integer |
Objectcode 1 |
|
|
OCTWO |
integer |
Objectcode 2 |
|
|
OD |
real |
Outer Diameter |
|
|
ODESP |
real(100) |
Owning design parameters |
|
|
OFFDIR |
dir |
Offset direction applied to repeat |
|
|
OFFDIS |
real |
Offset distance applied to repeat elements |
|
|
OFFSET |
real |
Offset |
|
|
OFFTOL |
string(1000) |
PPoint offset tolerance |
|
|
OFFTYP |
word |
Offset type: DELTA, LINEAR, RADIAL |
|
|
OGDSTS |
real(25) |
Distances to openings |
|
|
OGOING |
real |
Overall Going |
|
|
OKCLA |
logical |
True if element may be claimed |
|
|
OKCLH |
logical |
True if element and hierarchy may be claimed |
|
|
OKDROP |
logical |
True if element may be dropped |
|
|
OKDRPH |
element(5000) |
Primary elements preventing hierarchy drop |
|
|
OKREL |
logical |
True if element may be released |
|
|
OKRLEH |
element(5000) |
Primary elements preventing hierarchy release |
|
|
OKRLEX |
logical |
True if element may be extract released |
|
|
OKRLH |
logical |
True if element and hierarchy may be released |
|
|
OLCOLO |
integer |
Outline colour |
|
|
OLCONU |
integer |
Outline colour number |
|
|
OLDKEY |
integer |
Old key |
|
|
OLENGTH |
real |
Overall length |
|
|
OLIS |
word(2000) |
List of all possible owner types |
|
|
OLOFF |
real |
OffsetLine offset from baseline |
|
|
OLPEN |
integer |
Outline pen |
|
|
OLSTREF |
element |
Outline linestyle Reference |
|
|
OLSTYL |
integer |
Outline linestyle |
|
|
OMITFG |
logical |
Omission flag |
|
|
ONPJ |
pos |
Owning neutral point of joint (steelwork) |
|
|
ONPO |
real(2) |
ONTO Point, position of view in the region |
|
|
ONPS |
pos |
Owning neutral point of section (steelwork) |
|
|
OPAR |
real(100) |
Owning parameters - catalogue component |
|
|
OPCLA |
word |
Claim Access Control Operation |
|
|
OPCOP |
word |
Copy-From Access Control Operation |
|
|
OPCRE |
word |
Create Access Control Operation |
|
|
OPCREF |
element |
Offpage connector reference |
|
|
OPDEL |
word |
Delete Access Control Operation |
|
|
OPDI |
dir |
Origin plane direction |
|
|
OPDRO |
word |
Drop Access Control Operation |
|
|
OPERAT |
string(26) |
Operator |
|
|
OPEXP |
word |
Export Access Control Operation |
|
|
OPHEIG |
real |
Operational Height |
|
|
OPISS |
word |
Issue Access Control Operation |
|
|
OPLENG |
real |
Operational Length |
|
|
OPMOD |
word |
Modify Access Control Operation |
|
|
OPNSIZE |
real(2) |
Opening size |
|
|
OPOS |
pos |
Overlay sheet position |
|
|
OPOUT |
word |
Output (DATAL) Access Control Operation |
|
|
OPREMA |
real |
Operating pres. max |
|
|
OPREMI |
real |
Operating pres. min |
|
|
OPTEMP |
real |
Operational temperature |
|
|
OPWIDT |
real |
Operational Width |
|
|
ORI |
ori |
Orientation |
|
|
ORIA |
real(3) |
Orientation as angles |
|
|
ORIF |
logical |
Orientation flag |
|
|
ORIN |
word |
DRAFT user defined symbol orientation |
|
|
ORISE |
real |
Overall Rising |
|
|
ORNA |
string(1000) |
Originator text |
|
|
ORRF |
element |
Origin reference (for templates) |
|
|
OSDWG |
string(120) |
AutoCAD overlay name |
|
|
OSET |
logical |
Offset/VIEW position flag |
|
|
OSFN |
string(1024) |
Overlay sheet file |
|
|
OSHT |
real |
Overshoot |
|
|
OSLV |
real(12) |
Overlay sheet view layers visible |
|
|
OSRF |
element |
Overlay sheet ref |
|
|
OSTYPE |
word |
Short cut for "Type of owner" |
|
|
OTHLEN |
real |
Length of other intervals |
|
|
OTHNUM |
integer |
Number of other intervals |
|
|
OTMPMA |
real |
Operating temp. max |
|
|
OTMPMI |
real |
Operating temp. min |
|
|
OUAREA |
real |
Area of outer contour |
|
|
OUPRTR |
element |
Outside paint reference |
|
|
OUTD |
string(1000) |
Outside diameter |
|
|
OUTFRF |
element |
Reference of matching outfit object |
|
|
OUTSD |
string(1000) |
Outside shield diameter |
|
|
OVCWIDTH |
real |
Overall cables width |
|
|
OVRSH |
real |
Overshoot (d-measure) for unsymmetrical flange |
|
|
OWNC |
word |
Owning connection type |
|
|
OWNER |
element |
Element owner in database hierarchy |
|
|
OWNEXPRESSION |
string(4000) |
Owner expression |
|
|
OWNEXTYPE |
string(60) |
Owner expression type |
|
|
OWNLST |
element(100) |
Owning hierarchy |
|
|
PAAX |
string(30) |
Direction of axis |
|
|
PAGE |
integer(500) |
Page in diagram |
|
|
PAINTO |
string(26) |
Painting other side |
|
|
PAINTT |
string(26) |
Painting this side |
|
|
PAIREF |
element |
Reference to a PAINT element |
|
|
PALIG |
real |
Panel alignment |
|
|
PALLAN |
real |
integer |
Ppoint allowed angle |
|
PANESI |
real(2) |
Panel Size |
|
|
PANG |
string(1000) |
Angle subtended |
|
|
PANREF |
element |
Panel reference |
|
|
PANSCD |
integer |
Panel storing code |
|
|
PANSID |
integer |
Side of panel |
|
|
PANSTC |
integer |
Panel storing code |
|
|
PARA |
real(100) |
Parameters |
|
|
PARAL |
logical |
True if tap parallel to referred seam |
|
|
PARCOLUMN |
element |
Parent column |
|
|
PARENT |
element |
elemtype |
Reference of ascendant element of specified type |
|
PARM |
real(6) |
Parameters |
|
|
PARNAM |
string(256) |
Part name |
|
|
PARREF |
element(10) |
Part reference |
|
|
PARTNUMBER |
integer |
Part number of a spooled component or leave tube |
|
|
PASS |
string(7) |
Password |
|
|
PASSQ |
integer |
Password Quality |
|
|
PATADV |
real |
Line Pattern Advance value |
|
|
PATDEF |
integer(20) |
Pattern Definition |
|
|
PATH |
element(500) |
Path |
|
|
PATHTM |
real |
Path time for selected burning machine |
|
|
PATNAM |
string |
Pattern Name |
|
|
PATOFF |
real |
Line Pattern Offset |
|
|
PATREP |
real |
Pattern Repeat |
|
|
PAXI |
string(30) |
Axial direction |
|
|
PBAX |
string(30) |
Direction |
|
|
PBBT |
string(1000) |
Bottom B length |
|
|
PBDI |
string(1000) |
Distance to bottom surface |
|
|
PBDM |
string(1000) |
Snout bottom diameter |
|
|
PBENDNUMBER |
integer |
Spooling pulled bend number |
|
|
PBOF |
string(1000) |
B offset |
|
|
PBOP |
pos |
integer |
Bottom of pipe |
|
PBOR |
string(1000) |
Bore |
|
|
PBTP |
string(1000) |
Top B length |
|
|
PCAX |
string(30) |
Direction of C offset |
|
|
PCBT |
string(1000) |
Bottom C length |
|
|
PCODA |
integer |
Precision code angles |
|
|
PCODE |
integer |
Precision code |
|
|
PCODF |
integer |
Precision code fractions |
|
|
PCODI |
integer |
Precision code imperial |
|
|
PCODM |
integer |
Precision code metric |
|
|
PCOF |
string(1000) |
C offset |
|
|
PCON |
string(1000) |
Connection type |
|
|
PCONDE |
string(120) |
integer |
Ppoint connection description |
|
PCORRO |
real |
integer |
P Tube corrosion |
|
PCPIDV |
element(10000) |
Enabled for project copy |
|
|
PCPSET |
element(10000) |
Enabled for project copy |
|
|
PCREF |
integer(4) |
integer |
Ppoint and ref of connected piping component |
|
PCRFA |
element(500) |
All spools that contain this element |
|
|
PCTP |
string(1000) |
Top C length |
|
|
PCWALL |
real |
integer |
Ppoint connect wall thickness |
|
PDAREF |
element |
Pipe data table reference |
|
|
PDEFI |
string |
Primitive Definition |
|
|
PDEREF |
element |
integer |
Pipe data element reference |
|
PDIA |
string(1000) |
Diameter parameter |
|
|
PDIR |
dir |
integer |
Ppoint direction |
|
PDIS |
string(1000) |
Distance parameter |
|
|
PDTINT |
integer(2) |
Production date |
|
|
PDTTXT |
string(22) |
Production date text |
|
|
PERS |
real |
Perspective angle |
|
|
PFLALL |
string(1000) |
Flange allowance parameter |
|
|
PFLOFF |
string(1000) |
Flange offset parameter |
|
|
PFON |
integer |
Projection line text font |
|
|
PFONTN |
string(80) |
Projection line text font name |
|
|
PFRE |
element |
Pfitting reference for Cofittings |
|
|
PFREQ |
logical |
Picture file required flag |
|
|
PGRD |
real |
integer |
Ppoint gradient |
|
PHBO |
real |
Pipe head bore |
|
|
PHBP |
pos |
Bottom of pipe head |
|
|
PHCO |
word |
Pipe head connection type |
|
|
PHDR |
dir |
Pipe head direction |
|
|
PHEI |
string(1000) |
Height |
|
|
PHGR |
real |
Pipe head gradient |
|
|
PHOD |
real |
Pipe head outside diameter |
|
|
PHPO |
pos |
Pipe head position |
|
|
PHTP |
pos |
Top of pipe head |
|
|
PICF |
string(73) |
Picture filename |
|
|
PICFD |
logical |
Picture file distribution flag |
|
|
PICHTY |
word |
Hard type of picture |
|
|
PICSTY |
word |
Soft type of picture |
|
|
PINDEN |
real |
Pin Density |
|
|
PIPSYM |
logical |
Pipe-end symbol flag |
|
|
PITCH |
real(10) |
Pitch of stair flight |
|
|
PITCHO |
real |
Angular offset from ladder pitch |
|
|
PJUS |
string |
Projection line text justification |
|
|
PKDI |
real |
Proportional distance along Pline |
|
|
PKEY |
word |
Pline identifier key |
|
|
PLALEN |
real |
Raw plate length |
|
|
PLANU |
string(1000) |
Planning Unit |
|
|
PLANV |
logical |
Is Plan View |
|
|
PLAREA |
real |
Area |
|
|
PLATYP |
string(26) |
Type of plate , for example. Plate, Bracket, Clip,... |
|
|
PLAWDT |
real |
Raw plate width |
|
|
PLAX |
string(120) |
2D direction angle |
|
|
PLCL |
real |
Projection line clearance |
|
|
PLCLFL |
logical |
Proj. line clearance flag |
|
|
PLCN |
logical |
word |
Pline centreline flag |
|
PLCO |
word |
word |
Pline connection |
|
PLCOLO |
integer |
Projection line colour |
|
|
PLCONU |
integer |
Projection line colour number |
|
|
PLDE |
string(120) |
word |
Pline description |
|
PLDI |
real(3) |
Projection line direction |
|
|
PLED |
dir |
Plane entry direction |
|
|
PLEN |
pos |
word |
Pline end |
|
PLENCU |
pos |
word |
Pline end, allowing for cutback |
|
PLFG |
logical |
Plines flag |
|
|
PLINON |
logical |
Pline-required flag |
|
|
PLLE |
integer(2) |
word |
Pline level |
|
PLLS |
word(100) |
List of valid Plines |
|
|
PLNA |
word(100) |
List of available Pline names |
|
|
PLNCOL |
integer |
Pline colour |
|
|
PLNCON |
integer |
Pline colour number |
|
|
PLNP |
integer |
Pline pen |
|
|
PLNSTREF |
element |
Pline linestyle Reference |
|
|
PLNSTY |
integer |
Pline linestyle |
|
|
PLOR |
ori |
word |
Pline orientation |
|
PLPM |
word |
Plane pipe packing method - nearest or weighted |
|
|
PLPN |
integer |
Projection line pen |
|
|
PLPP |
word |
Plane pipe positioning code word used by Router |
|
|
PLPU |
word |
word |
Pline purpose |
|
PLRD |
dir |
Plane routine direction |
|
|
PLREFS |
element(5000) |
Pline references |
|
|
PLRF |
element |
Plane reference |
|
|
PLSP |
real |
Projection line text line spacing |
|
|
PLST |
pos |
word |
Pline start |
|
PLSTCU |
pos |
word |
Pline start, allowing for cutback |
|
PLSTREF |
element |
Projection linestyle Reference |
|
|
PLSTYL |
integer |
Projection linestyle |
|
|
PLTU |
logical |
word |
Pline tube flag |
|
PLTX |
string(1000) |
Projection line text |
|
|
PLVI |
word(200) |
List of visible Plines |
|
|
PLVIF |
integer |
word |
Pline visibility flag |
|
PLWW |
word |
Plane wall to wall positioning code used by Router |
|
|
PMAX |
integer |
Maximum part number in current spool drawing |
|
|
PMLFUN |
string(120) |
PML Function name |
|
|
PMLNAM |
string(120) |
Name of Pmlobject |
|
|
PMOD |
string |
Plane mode |
|
|
PNAM |
string(12) |
Property description |
|
|
PNTUV |
pos |
Point2D |
|
|
PNTXYZ |
pos |
Point3D |
|
|
POCK |
word |
Is a branch component in a pocket |
|
|
POD |
real |
integer |
Ppoint outside diameter |
|
POEF |
logical |
Post-evaluation flag |
|
|
POFF |
string(1000) |
Offset |
|
|
POINUM |
integer |
Point Num |
|
|
POIS |
real |
Spot value of Poissons ratio |
|
|
POITYP |
string(120) |
Point type |
|
|
POS |
pos |
Position |
|
|
POSE |
pos |
End point position |
|
|
POSEE |
real |
Easting of end point position |
|
|
POSEU |
real |
Upping of end point position |
|
|
POSEV |
pos |
Position evaluation |
|
|
POSEY |
real |
Northing (Y coordinate) of end point position |
|
|
POSF |
logical |
Positioning flag |
|
|
POSFOR |
string |
Intelligent Text positional code word expansion style |
|
|
POSL |
word |
Positioning line |
|
|
POSN |
real |
Northing of position |
|
|
POSNO |
integer |
Position number |
|
|
POSREF |
element |
Reference to point |
|
|
POSS |
pos |
Start point position |
|
|
POSSE |
real |
Easting of start point position |
|
|
POSSN |
real |
Northing of start point position |
|
|
POSSU |
real |
Upping of start point position |
|
|
POSTSP |
real |
Default post spacing |
|
|
POSU |
real |
Upping of position |
|
|
POSX |
real |
Easting (X coordinate) of position |
|
|
POSXP |
integer(500) |
Position expression |
|
|
POWFAC |
real |
Powder point factor |
|
|
PPANFL |
real |
Pipe Piece Angle between flanges |
|
|
PPAREF |
element |
Pipe Piece Arrive Reference |
|
|
PPBO |
real |
integer |
Ppoint bore |
|
PPBRAD |
real(500) |
Pipe piece bend radii |
|
|
PPBRAT |
real(500) |
Pipe piece bend ratio |
|
|
PPCNBD |
logical |
Pipe piece contains bends |
|
|
PPCO |
word |
integer |
Ppoint connection type |
|
PPCOU |
integer |
Number of valid Ppoints |
|
|
PPCUTL |
real |
Cut Length |
|
|
PPDE |
string(120) |
integer |
Ppoint description |
|
PPDI |
integer |
Ppoint number for direction |
|
|
PPEFR |
logical |
Leave flange required |
|
|
PPER |
element |
Pipe piece end reference |
|
|
PPEXST |
logical |
integer |
True if Ppoint exists |
|
PPFINL |
real |
Finished Length |
|
|
PPFMCV |
logical |
Pipe piece fabrication machines verified |
|
|
PPHEI |
real |
integer |
Ppoint height |
|
PPLREF |
element |
Pipe Piece Leave Reference |
|
|
PPLS |
integer(200) |
List of valid Ppoints |
|
|
PPMODI |
logical |
Pipe piece modified |
|
|
PPNU |
integer |
Design PPoint/Port number |
|
|
PPOFFT |
real |
integer |
Ppoint offset |
|
PPOS |
pos |
integer |
Ppoint position |
|
PPRFA |
element(500) |
All components in the PipePiece |
|
|
PPRO |
string(1000) |
parameterized Property Expression |
|
|
PPSFR |
logical |
Arrive flange required |
|
|
PPSK |
word |
integer |
Ppoint pskey |
|
PPSPEC |
element |
Pipe Piece Specification |
|
|
PPSR |
element |
Pipe piece start reference |
|
|
PPUR |
word |
integer |
Ppoint purpose |
|
PPVBMC |
element |
Return the bending machine IF the pipe piece is verified |
|
|
PPVERI |
word |
Pipe piece verified |
|
|
PPVI |
integer(200) |
List of visible Ppoints |
|
|
PPVIF |
integer |
integer |
Ppoint visibility flag |
|
PPVWMC |
element |
Return the welding machine IF the pipe piece is verified |
|
|
PPWID |
real |
integer |
Ppoint width |
|
PQAANG |
real |
integer |
Angle between alignment direction of specified pp and adjacent component |
|
PQANG |
real |
integer |
Angle between specified Ppoint and adjacent component |
|
PQBORE |
logical |
integer |
TRUE if specified Ppoint has same bore as adjacent |
|
PQCON |
logical |
integer |
TRUE if leave Ppoint has Correct connection type |
|
PQOFF |
real |
integer |
Offset between specified Ppoint and adjacent component |
|
PQUA |
word |
Property qualifier |
|
|
PRAD |
string(1000) |
Radius |
|
|
PRAV |
real |
Average pressure |
|
|
PRDE |
string(250) |
word |
Property default |
|
PREF |
logical |
Pre-evaluation flag |
|
|
PREFIX |
string(120) |
Prefix |
|
|
PREPPR |
string(26) |
Preparation information |
|
|
PREPT |
real |
Preparation time |
|
|
PRES |
real |
Pressure |
|
|
PRFC |
string(1000) |
Pressure factor |
|
|
PRFELE |
element |
Cableway profile element |
|
|
PRFG |
logical |
Profile flag |
|
|
PRFL |
string(120) |
Profile |
|
|
PRFOBS |
integer |
Cableway profile obstructions |
|
|
PRICEE |
real |
Price estimate |
|
|
PRIMDB |
string |
Global status of DB, primary or secondary |
|
|
PRIMEM |
logical |
Primary member |
|
|
PRIMSY |
element |
Reference of the primary system elements |
|
|
PRIMTY |
logical |
True if element is primary |
|
|
PRITYP |
string(120) |
Gpart Primary type |
|
|
PRJD |
string(180) |
Project description |
|
|
PRJID |
string(8) |
Project id. Available on STAT or GSTAT element |
|
|
PRJL |
logical |
Project lock |
|
|
PRJN |
string(17) |
Project number |
|
|
PRJSTA |
word |
Access Control project status |
|
|
PRLS |
word(100) |
List of valid properties - catalogue or design |
|
|
PRMA |
real |
Maximum pressure |
|
|
PRMDIR |
dir |
Primary Direction |
|
|
PRMI |
real |
Minimum pressure |
|
|
PRMLOC |
element |
Primary location |
|
|
PRMMEM |
logical |
True if there are any primary elements amongst descendants |
|
|
PRMOWN |
element |
Primary owning element (will be itself if primary) |
|
|
PRMRF |
element |
Primary Location Element |
|
|
PRMVI |
logical |
Draughting primitive visibility |
|
|
PROCDE |
string(2400) |
PROCess DEscription |
|
|
PRODID |
string(104) |
Product id |
|
|
PRODRF |
element |
Reference to Production Object |
|
|
PRODUCTION |
real |
Production level radiation |
|
|
PROJID |
integer(3) |
PROJID - on the DB element |
|
|
PROLEN |
real |
Raw profile length |
|
|
PROMIX |
integer |
Index of Promote Status Value |
|
|
PROMPT |
string(160) |
User prompt |
|
|
PROP |
string(250) |
word |
Property value from catalogue or design dataset |
|
PROPG |
logical |
DB propagation flag |
|
|
PROPRE |
real |
attr |
Calculated Property Real Attribute |
|
PROSID |
integer |
Plate side with most profile markings |
|
|
PRPU |
word |
word |
Property purpose |
|
PRTI |
string(120) |
word |
Property title |
|
PRTIDL |
string(132) |
Long part id |
|
|
PRTIDM |
string(132) |
Module part id |
|
|
PRTIDS |
string(132) |
Short part id |
|
|
PRTLST |
string(26) |
Parts list name |
|
|
PRTREF |
element |
Part reference |
|
|
PRTRTX |
string(1000) |
word |
Part element R text |
|
PRTSTX |
string(1000) |
word |
Part element S text |
|
PRTTTX |
string(1000) |
word |
Part element T text |
|
PRTXRF |
element(500) |
Return reference from PART element to SPCOs |
|
|
PRVRF |
element |
Reference to previous owner of DB |
|
|
PRVSES |
integer |
integer |
Previous Session to that specified |
|
PSARFA |
element(500) |
Pipespool arrive references |
|
|
PSATTS |
word(500) |
List of pseudo attributes |
|
|
PSESS |
integer |
integer |
Previous session number |
|
PSFG |
logical |
Piping component symbol flag |
|
|
PSIZE |
real(2) |
Panel size |
|
|
PSKE |
word |
Key for ISODRAFT |
|
|
PSLRFA |
element(500) |
Pipespool leave references |
|
|
PSPE |
element |
Pipe specification |
|
|
PSPIN |
integer |
Ppoint number showing position of spindle |
|
|
PSTAT |
integer |
Plane status |
|
|
PSTF |
element |
Pointset reference |
|
|
PSTR |
element |
Structural Pline set reference |
|
|
PSTYP |
word |
Spool Type |
|
|
PSVLD |
logical |
Pipespool valid |
|
|
PTAN |
string |
Projection line text angle flag |
|
|
PTBO |
real |
Pipe tail bore |
|
|
PTBP |
pos |
Bottom of pipe tail |
|
|
PTCDI |
string(1000) |
parameterized direction |
|
|
PTCH |
real |
Projection text character height |
|
|
PTCO |
word |
Pipe tail connection type |
|
|
PTCOLO |
integer |
Projection text colour |
|
|
PTCONU |
integer |
Projection text colour number |
|
|
PTCPOS |
string(250) |
parameterized position |
|
|
PTDI |
string(1000) |
Distance to top surface |
|
|
PTDM |
string(1000) |
Snout top diameter |
|
|
PTDR |
dir |
Pipe tail direction |
|
|
PTDTRE |
element |
Part Data set reference |
|
|
PTEM |
real |
Pipework temperature |
|
|
PTEPOS |
string(250) |
parameterized end position |
|
|
PTFA |
element(17) |
Point references |
|
|
PTGR |
real |
Pipe tail gradient |
|
|
PTLH |
real |
Projection text letter height |
|
|
PTNB |
integer(20) |
Old spooler bolt part number |
|
|
PTNH |
integer |
Old spooler head tube part number |
|
|
PTNO |
integer |
Old spooler component part number |
|
|
PTNT |
integer |
Old spooler tube part number |
|
|
PTOD |
real |
Pipe tail outside diameter |
|
|
PTOF |
real(2) |
Projection line text offset |
|
|
PTOLER |
real |
Tolerance on a design property |
|
|
PTOP |
pos |
integer |
Top of pipe |
|
PTPN |
integer |
Projection text pen |
|
|
PTPO |
pos |
Pipe tail position |
|
|
PTPTXT |
string(26) |
Profile type. for example. Stiffener, Flange,... |
|
|
PTRE |
element |
Point set reference |
|
|
PTRF |
element |
Point reference |
|
|
PTS |
integer(6) |
Line definition points |
|
|
PTSP |
string(120) |
Paint specification |
|
|
PTSPOS |
string(250) |
parameterized start position |
|
|
PTTP |
pos |
Top of pipe tail |
|
|
PTYP |
word |
Property type |
|
|
PUCD |
string(100) |
Paint Code |
|
|
PUINCD |
string(120) |
Inside punch code |
|
|
PUNCHT |
real |
Punching time |
|
|
PUNI |
string(32) |
Data Property Units |
|
|
PUOUCD |
string(120) |
Outside punch code |
|
|
PURCH |
string(26) |
Purchase information |
|
|
PURP |
word |
Description code word |
|
|
PVIF |
integer |
PPoint/Pline visibility filter |
|
|
PVNO |
integer |
Picture version number |
|
|
PWALLT |
real |
integer |
Ppoint wall thickness |
|
PWAS |
string(1000) |
Percentage wastage factor |
|
|
PWID |
string(1000) |
Width / Wall thickness |
|
|
PWWFAC |
real |
Powder way factor |
|
|
PX |
string(1000) |
Cartesian X position |
|
|
PXBS |
string(1000) |
Inclination of bottom surface to local X axis |
|
|
PXLE |
string(1000) |
X length |
|
|
PXTS |
string(1000) |
Inclination of top surface to local X axis |
|
|
PY |
string(1000) |
Cartesian Y position |
|
|
PYBS |
string(1000) |
Inclination of bottom surface to local Y axis |
|
|
PYLE |
string(1000) |
Y length |
|
|
PYTS |
string(1000) |
Inclination of top surface to local Y axis |
|
|
PZ |
string(1000) |
Cartesian Z position |
|
|
PZAXI |
string(30) |
Alignment axial direction |
|
|
PZDIR |
dir |
integer |
Ppoint alignment direction |
|
PZLE |
string(1000) |
Z length |
|
|
QALLSI |
integer |
AllocSize |
|
|
QMXUPT |
integer |
MaxUserPtr |
|
|
QNELEM |
integer |
QNoElem |
|
|
QOBJSI |
integer |
ObjectSize |
|
|
QTYPE |
word |
Type of question |
|
|
QUACD |
integer |
Quality code |
|
|
QUAL |
integer |
Qualifier |
|
|
QUAN |
integer |
Quantity (always one!) |
|
|
QUAPAI |
string(26) |
Paint specification |
|
|
QUATXT |
string(26) |
Quality |
|
|
QUES |
word |
Question |
|
|
QUSEXP |
integer(250) |
question expression |
|
|
RADD |
real |
Default Radius value |
|
|
RADF |
real |
Radius attractor factor |
|
|
RADI |
real |
Radius |
|
|
RADISP |
real(10000) |
Radius Spacing |
|
|
RADL |
real(2) |
Radius limits (Min/Max) |
|
|
RADS |
logical |
Radius set flag - ignore Radius values if FALSE |
|
|
RAILHE |
real(15) |
Heights of rails measured from path |
|
|
RAILTR |
real(10000) |
Rail Trim |
|
|
RANANG |
real(32) |
elemtype |
Range of available angles for bends and elbows |
|
RANEQUIP |
real |
Range of the nearest equipment |
|
|
RANRAD |
real(32) |
elemtype |
Range of available radii |
|
RATFAC |
real |
Rationalisation factor |
|
|
RATI |
real |
Pressure rating |
|
|
RATPOT |
string(15) |
Rationalisation post text |
|
|
RATPRE |
string(15) |
Rationalisation pre text |
|
|
RATTAL |
element(500) |
word |
Ratta list |
|
RATTAL |
element(500) |
word |
Rnode list |
|
RAWNAM |
string(500) |
Name only |
|
|
RAWPLA |
element |
Raw Plate |
|
|
RAWPRO |
string(26) |
Name of raw profile |
|
|
RCOD |
string |
Direction of region vertical on sheet |
|
|
RCOF |
pos |
Rough centre of gravity |
|
|
RCOU |
integer |
Number of rules on element |
|
|
RDEF |
real(3) |
Port rotation flexibility defaults |
|
|
REACT |
string(1000) |
Reactance |
|
|
READONLY |
logical |
Read only |
|
|
REALEV |
real |
Real evaluation |
|
|
REALXP |
integer(500) |
Real expression |
|
|
RECOMM |
string(256) |
Release to 3D comment |
|
|
REDATE |
string(12) |
Release to 3D date |
|
|
REDREF |
element |
Reducer table reference |
|
|
REDTYPE |
integer |
Reducer Type |
|
|
REDXRF |
element(500) |
Return reference from Reducer Table element to SPECs |
|
|
REF |
element |
Reference of the element |
|
|
REFA |
word |
Reference attribute used in ports |
|
|
REFI |
integer |
Reference array index |
|
|
REFL |
word(200) |
Types of elements (including UDETs) that can be pointed to by a reference attribute |
|
|
REFLCL |
logical |
True if reflected in CL |
|
|
REFLEVEL |
integer |
Reference Level |
|
|
REFMOD |
integer |
Reflection Mode |
|
|
REFSIZ |
integer |
Reference size |
|
|
REPCOU |
integer |
Rule Repeat Counter |
|
|
REPSEQ |
integer |
Sequence no. for template repeat element |
|
|
REPTXT |
string |
Reporter text used for element type |
|
|
REQUIRED |
logical |
Required |
|
|
RESIS |
string(1000) |
Resistance |
|
|
RESO |
real |
Model Resolution (distance) |
|
|
RESTAT |
integer |
Release to 3D status |
|
|
REUSER |
string(50) |
Release to 3D user |
|
|
REV |
integer |
Pipe Revision number |
|
|
REVDIR |
logical |
Reverse Direction flag |
|
|
REWIDTH |
real |
Reduced width |
|
|
RFLAG |
word |
Type of real answer NONE, SINGle, RANGe or MULTi |
|
|
RFLF |
real(3) |
Rotational spring values |
|
|
RGBCOL |
real(3) |
RGB colour vector |
|
|
RHOST |
string(120) |
Host computer name or IP address of remote machine |
|
|
RINE |
real(3) |
Rotational inertia vector |
|
|
RINS |
real |
Inside radius |
|
|
RISE |
real |
Tread Rise |
|
|
RLAC |
integer(500) |
Rule action array |
|
|
RLEX |
element(20) |
Array of references of special rules to exclude |
|
|
RLIM |
real(6) |
Rotation limits |
|
|
RLIN |
element(20) |
Array of references of special rules to include |
|
|
RLIS |
word(200) |
List of rules set |
|
|
RLLO |
integer(500) |
Rule logical array |
|
|
RLOC |
integer |
Branch Member Creation Status code (Router) |
|
|
RLSE |
integer(500) |
Rule selection array |
|
|
RMFL |
real(6) |
Rotational moment flexibility |
|
|
RMOF |
real(9) |
Rough moments of inertia |
|
|
RNAM |
string(120) |
Recipient name |
|
|
RNGCON |
element |
Rung Connection |
|
|
RNGOFF |
real |
Rung Offset |
|
|
RNREF |
element |
Route Node reference |
|
|
RNRIDF |
real |
Rung Rising Default |
|
|
RNRIMA |
real |
Rung Rising Minimum |
|
|
RNRIMI |
real |
Rung Rising Minimum |
|
|
RNTYPE |
word |
RNode Type |
|
|
ROBRRU |
element(500) |
Router Rules applying to a piping element or members |
|
|
ROLEREF |
element |
Access Control role references from ACR |
|
|
ROOMTY |
string(120) |
Room Type |
|
|
RORIEN |
logical |
True if repeat item is re-orientated upon rotation |
|
|
ROTN |
real(3) |
Rotation |
|
|
ROUT |
real |
Outside radius |
|
|
ROUTND |
element(100) |
Cable Preliminary route point |
|
|
ROUTRE |
element |
Route reference |
|
|
ROWCOL |
integer |
Row colour |
|
|
ROWCON |
integer |
Row colour number |
|
|
ROWNUM |
integer |
Pin row number |
|
|
ROWSTREF |
element |
Row linestyle Reference |
|
|
ROWSTY |
integer |
Row linestyle |
|
|
RPARM |
real(4) |
Rest plate parameters |
|
|
RPEN |
integer |
Pen for internal rows |
|
|
RPLCOD |
integer |
Rest plate code |
|
|
RPLNAM |
string(26) |
Rest plate name |
|
|
RPLNUM |
integer |
Number of rest plates |
|
|
RPLPOS |
real(4) |
Rest plate position |
|
|
RPLSET |
integer |
Rest plate set |
|
|
RPLTYP |
integer |
Rest plate type |
|
|
RPRE |
real |
Reference pressure |
|
|
RPRO |
real |
word |
Catalogue dataset property |
|
RPTX |
string(20) |
Text used when presenting the attribute to the user |
|
|
RRSF |
element |
Rep ruleset reference |
|
|
RSBOX |
real(6) |
Bounding box of RSO |
|
|
RSEQA |
integer(500) |
Sequence numbers for rule execution |
|
|
RSEQFA |
element(500) |
Rule sequence ref array for local names |
|
|
RSEQN |
integer |
Sequence number for rule execution |
|
|
RSESS |
string(120) |
integer |
Reason for creation of session |
|
RSET |
logical(3) |
Rotation limits set flag - ignore values if FALSE |
|
|
RSFFD |
integer |
Functional description on face |
|
|
RSFMC |
integer |
Material code on face |
|
|
RSFMS |
string(256) |
Material side on face |
|
|
RSFMT |
real |
Material thickness on face |
|
|
RSFSA |
logical |
Auto stiffening on face |
|
|
RSFSD |
string(256) |
Profile dim on face |
|
|
RSFSS |
string(256) |
Stiffener side on face |
|
|
RSFST |
integer |
Profile type on face |
|
|
RSFWT |
logical |
Watertight |
|
|
RSLBRA |
string(256) |
Bracket instance at limit |
|
|
RSLELE |
element |
Limiting element |
|
|
RSLPRE |
integer |
Profile end definition at limit |
|
|
RSPAN |
element(1000) |
Panel(s) defined on RSO |
|
|
RSPLN |
integer |
Principal plane of RSO |
|
|
RSRF |
real |
Rough surface area |
|
|
RSTYP |
integer |
Type of RSO |
|
|
RTEM |
real |
Reference temperature |
|
|
RTEX |
string(2000) |
R Text string |
|
|
RTYP |
string(12) |
Restraint type |
|
|
RULEER |
string(300) |
integer |
Text of "nth" rule error |
|
RULEMOD |
logical |
attr |
True if rule modified this session |
|
RULEMODC |
logical |
attr |
True if rule modified since comparison date |
|
RULEMODLIST |
word(500) |
integer |
List of rules modified since given session |
|
RULEMODLISTC |
word(500) |
List of rules modified since comparison date |
|
|
RULLIM |
real(6) |
Ruler limits |
|
|
RULRCO |
integer |
Ruler type code |
|
|
RULSET |
word(2000) |
List of rules set |
|
|
RULTCK |
integer |
Number of ticks between labelled ticks |
|
|
RUNGS |
integer |
Number of rungs |
|
|
RUNGSP |
real |
Rung Spacing |
|
|
RUSE |
integer |
True if PPROP/DPROP to be used as an RPROP in geomset/pointset attribute expression |
|
|
RVAU |
string(1000) |
Revision author |
|
|
RVDT |
string(12) |
Date of revision |
|
|
RVOL |
real |
Rough gross volume |
|
|
RVSN |
string(1000) |
Revision number |
|
|
RVTM |
string(120) |
Time of revision |
|
|
RWDOWN |
integer(2) |
Table linking RWELD elements to design WELD elements |
|
|
RWDOWN |
element |
Reference of associated WELD of RWELD element |
|
|
RWEI |
real |
Rough weight |
|
|
RWIDTH |
real |
Rung Width |
|
|
S |
real |
Position southing |
|
|
SAFC |
integer |
Safety class |
|
|
SAVDIR |
dir |
Cached direction |
|
|
SAVPOS |
pos |
Cached position |
|
|
SBRA |
element(10) |
SBOLT references |
|
|
SBRP |
element |
SBFR to RPLA reference link (Router) |
|
|
SCAL |
integer |
DRAFT user defined symbol scale factor |
|
|
SCALI |
real(500) |
ADP main view allowable scale list |
|
|
SCALIN |
logical |
Drafting symbol link scaling flag |
|
|
SCALPH |
logical |
ALPHA/NOALPHA flag |
|
|
SCAREF |
element(10) |
Area shape reference |
|
|
SCBREF |
element(50) |
Schematic element back reference |
|
|
SCDELI |
string(50) |
Delimiter |
|
|
SCDIGIT |
integer |
Digits |
|
|
SCEIRE |
element(60) |
Enhanced instrument relationship |
|
|
SCELOR |
element(20) |
Enhanced instrumentation loop reference array for schematic elements |
|
|
SCGTYP |
string(50) |
Schematic nozzle gtype |
|
|
SCHED |
string(10) |
Piping Schedule |
|
|
SCHELE |
element |
Schematic head element |
|
|
SCHEME |
string |
Scheme name |
|
|
SCHFF |
integer |
Schematic file format |
|
|
SCHLNK |
element |
Connectivity Schematic Link |
|
|
SCHTYP |
integer |
Schematic type |
|
|
SCIERTYPE |
word(60) |
Instrument enhanced reference type |
|
|
SCIIRE |
element(50) |
Instrument to instrument reference |
|
|
SCIIRTYPE |
word(50) |
Instrument to instrument reference type |
|
|
SCIPRE |
element(50) |
Instrument process reference |
|
|
SCIPRTYPE |
word(50) |
Instrument process reference type |
|
|
SCIREF |
element(10) |
Instrument reference |
|
|
SCIREL |
element(50) |
Instrument relationship |
|
|
SCIRLTYPE |
word(50) |
Instrument relationship type |
|
|
SCIRTY |
word(10) |
Instrument reference type |
|
|
SCLORE |
element(10) |
Instrumentation loop reference array for schematic elements |
|
|
SCOD |
string(3) |
Isodraft Compipe: Short code |
|
|
SCOPEREF |
element |
Access Control scope references from ACR |
|
|
SCOSEL |
integer(500) |
Access Control scope |
|
|
SCOSLX |
integer(500) |
Access Control scope |
|
|
SCPANA |
string(120) |
Schematic page name |
|
|
SCPATY |
word |
Schematic page type |
|
|
SCQUAN |
integer |
Quantity |
|
|
SCRAPT |
real |
Total scrap of raw plate area |
|
|
SCRAPU |
real |
Total scrap of used raw plate area |
|
|
SCREF |
element |
Schematic element reference |
|
|
SCSTYP |
string(257) |
Schematic stype |
|
|
SCSYSD |
element(500) |
System reference array for schematic diagrams |
|
|
SCSYSF |
element(10) |
System reference array for schematic elements |
|
|
SCTDIR |
dir |
Section Direction |
|
|
SCTELE |
element |
Schematic tail element |
|
|
SDISTA |
real |
Vertical Distance of Start |
|
|
SDTH |
real(3) |
Saddle thickness |
|
|
SDTINT |
integer(2) |
Splitting date |
|
|
SDTTXT |
string(22) |
Splitting date |
|
|
SECTYP |
string(120) |
Gpart Secondary type |
|
|
SEGE |
pos |
Segment end point position |
|
|
SEGS |
pos |
Segment start point position |
|
|
SENS |
string |
Rotational sense |
|
|
SEQU |
integer |
Sequence Position in Member List |
|
|
SESCLA |
integer |
Session Of Claim |
|
|
SESSC |
string(120) |
integer |
Comment for specified session |
|
SESSCA |
integer(2000) |
List of pairs of DB number, last session number for all referenced DBs |
|
|
SESSCH |
integer(2000) |
As for SESSCA, but searches all descendants for referenced DBs |
|
|
SESSD |
string(120) |
integer |
Date of specified Session |
|
SESSM |
integer |
attr |
Session Of Last Modification |
|
SESSNO |
integer |
Current opened Session |
|
|
SESSU |
string(120) |
integer |
User creating specified session |
|
SETDATE |
string(120) |
Set Date |
|
|
SEXPND |
element(10000) |
All descendant elements in secondary hierarchy |
|
|
SFCODE |
integer |
Stiffener Code |
|
|
SFLIMI |
word |
Spooling limits |
|
|
SFOR |
real(3) |
Start force vector component |
|
|
SFREF |
element |
Return reference from piping component or leave tube to spool or field element |
|
|
SHAP |
string(1000) |
Shape modulus |
|
|
SHFALG |
real |
Shrinkage factor along main direction |
|
|
SHFPRP |
real |
Shrinkage factor perpendicular to main direction |
|
|
SHFSEA |
real |
Shrinkage factor for seams perp. to main direction |
|
|
SHIPNO |
string(80) |
Ship number |
|
|
SHIPX |
string(20) |
Ship X position |
|
|
SHIPY |
string(20) |
Ship Y position |
|
|
SHIPZ |
string(20) |
Ship Z position |
|
|
SHOC |
real(3) |
Shock load vector |
|
|
SHOP |
logical |
Shop/Site flag |
|
|
SHOPRI |
logical |
Shop Primer |
|
|
SHPSYM |
string(40) |
Shape symbol text |
|
|
SHPUV |
pos |
Point defining shrinkage |
|
|
SHRF |
element |
Reference to associated sheet or library |
|
|
SHTNUM |
integer |
Sheet Number |
|
|
SHVUV |
dir |
Vector defining shrinkage |
|
|
SIF |
real(3) |
Stress intensification factor |
|
|
SIGF |
integer |
Significant figures |
|
|
SIGREF |
element |
Significant point reference |
|
|
SITEM |
element |
Reference from secondary hierarchy |
|
|
SIZE |
real(2) |
Sheet/region size |
|
|
SIZEDB |
integer |
Size of DB |
|
|
SJUS |
word |
Surface justification for PALJs |
|
|
SKEY |
string(4) |
Symbol key |
|
|
SKEYSCALE |
integer |
Universal SKEY scale factor |
|
|
SLENGTH |
real |
Side length |
|
|
SLOPEF |
logical |
SLOPEF (True if its a sloping wall else step change) |
|
|
SLOREF |
element |
Pipe slope reference |
|
|
SLRAP |
element(500) |
Sorted list of RATTA after POINTR |
|
|
SLRBP |
element(500) |
Sorted list of RATTA before POINTR |
|
|
SMAX |
integer |
Maximum spool number in current spool drawing |
|
|
SMEMB |
element(10000) |
Immediate members in secondary hierarchy |
|
|
SMNO |
integer |
SMODU number |
|
|
SMOD |
string |
Sectioning mode |
|
|
SMOM |
real(3) |
Start moment component |
|
|
SOLFILLED |
logical |
Solid Filled Flag |
|
|
SORF |
element |
Source reference (for automatic application) |
|
|
SOUR |
string(1000) |
Source macro |
|
|
SPBREF |
element |
Reference to boundary element |
|
|
SPECIF |
logical |
True if outer panel contour on PS/SB are different |
|
|
SPIN |
string(4) |
DRAFT user defined spindle symbol/skey name |
|
|
SPINRE |
element |
Reference to external inventory element |
|
|
SPKBRK |
logical |
ATTA flag to treat as a real element |
|
|
SPKCHG |
element |
flag to show where a spec change occurs in a branch |
|
|
SPKDI |
real |
Proportional distance of start point along Pline |
|
|
SPLA |
string |
Name of spigot plate |
|
|
SPLATE |
word |
Section plate |
|
|
SPLH |
string(120) |
Old spooler head tube spool number |
|
|
SPLMEM |
element(1500) |
Spooling table attribute on SPOOL or FIELD elements |
|
|
SPLN |
string(120) |
Old spooler component spool number |
|
|
SPLNUM |
integer |
Spool number |
|
|
SPLP |
string(120) |
Spool number prefix |
|
|
SPLPARENT |
element(500) |
elemtype |
Branches referenced by a SPLDRG, SPOOL or FIELD |
|
SPLT |
string(120) |
Old spooler tube spool number |
|
|
SPLTBL |
integer(2000) |
Table linking SPOOL & FIELD elements to piping components |
|
|
SPLVOLUME |
real(3) |
Volume of a SPOOL element |
|
|
SPMA |
real |
word |
Spec angle maximum answer |
|
SPMACC |
string(25) |
Access authorization code |
|
|
SPMACD |
string(75) |
Access authorization description |
|
|
SPMALL |
real |
Structural Allowance |
|
|
SPMAOF |
real |
Offset AFT |
|
|
SPMARA |
real |
Area of face |
|
|
SPMARE |
real |
Area of face |
|
|
SPMATP |
integer |
Type of space arrangement |
|
|
SPMBB |
real(6) |
Bounding box |
|
|
SPMBIN |
integer |
Boundary identification number |
|
|
SPMBNA |
string(80) |
Boundary name |
|
|
SPMBOF |
real |
Offset BOT |
|
|
SPMBOX |
real(6) |
Bounding box |
|
|
SPMBR |
element |
Bounding reference |
|
|
SPMCAS |
real |
Calculated steel paint area of space contents |
|
|
SPMCDE |
string(75) |
Content description |
|
|
SPMCFA |
real |
Floor area |
|
|
SPMCLI |
word(2000) |
List of customer attributes for space |
|
|
SPMCOL |
integer |
Colour |
|
|
SPMCOS |
real(3) |
Calculated centre of steel structure |
|
|
SPMCOV |
pos |
Centre of Volume |
|
|
SPMCTY |
string(25) |
Content type code |
|
|
SPMCWB |
real |
Calculated length of butt weld |
|
|
SPMCWC |
real |
Calculated Weight of space Contents |
|
|
SPMCWL |
real |
Calculated length of fillet weld |
|
|
SPMCWS |
real |
Calculated Weight of steel structure |
|
|
SPMDE |
real |
Density |
|
|
SPMEAS |
real |
Estimated steel paint area of space contents |
|
|
SPMEHC |
real |
Estimated HVAC Capacity |
|
|
SPMEN |
string(26) |
Envelop name |
|
|
SPMEPC |
real |
Estimated Power Consumption |
|
|
SPMEWB |
real |
Estimated length of butt weld |
|
|
SPMEWC |
real |
Estimated Weight of space Contents |
|
|
SPMEWL |
real |
Estimated length of fillet weld |
|
|
SPMEWS |
real |
Estimated weight of steel structure |
|
|
SPMFAR |
real |
Face area |
|
|
SPMFCL |
string(20) |
Fire class |
|
|
SPMFLW |
real |
Full load weight |
|
|
SPMFOF |
real |
Offset FWD |
|
|
SPMFST |
integer |
Face state |
|
|
SPMHSN |
string(26) |
Hull surface name |
|
|
SPMLSC |
string(25) |
Space Category |
|
|
SPMMVO |
real |
Total (moulded) volume |
|
|
SPMNBI |
integer |
Next boundary identification number |
|
|
SPMNOC |
string(25) |
Noise category code |
|
|
SPMNOD |
string(75) |
Noise category description |
|
|
SPMNVO |
real |
Net volume |
|
|
SPMPED |
real |
Permeability Damage |
|
|
SPMPER |
real |
Permeability |
|
|
SPMPOF |
real |
Offset PS |
|
|
SPMPP |
real(5) |
Precise properties |
|
|
SPMPU |
string(25) |
Purpose code |
|
|
SPMRDH |
real |
Required deck height |
|
|
SPMRFA |
real |
Required floor area |
|
|
SPMRSE |
string(25) |
Required service code |
|
|
SPMRSN |
string(26) |
Reference surface name |
|
|
SPMRTE |
element |
Reference to envelop space |
|
|
SPMSAC |
string(25) |
Safety category code |
|
|
SPMSAD |
string(75) |
Safety category description |
|
|
SPMSAN |
string(80) |
Space arrangement name |
|
|
SPMSBD |
element(500) |
Space boundary definitions |
|
|
SPMSEC |
string(25) |
Security classification code |
|
|
SPMSED |
string(75) |
Security classification description |
|
|
SPMSFI |
integer |
Subface identification number |
|
|
SPMSFP |
element |
Returns the space that contains the given point |
|
|
SPMSOF |
real |
Offset SB |
|
|
SPMSS |
integer |
Space state |
|
|
SPMSTP |
integer |
User defined subtype |
|
|
SPMSWT |
integer |
Type of space world |
|
|
SPMTHC |
string(25) |
Thermal insulation code |
|
|
SPMTHD |
string(75) |
Thermal insulation description |
|
|
SPMTIC |
string(25) |
Compartment tightness code |
|
|
SPMTID |
string(75) |
Compartment tightness description |
|
|
SPMTOF |
real |
Offset TOP |
|
|
SPMTOL |
integer |
Type of limits |
|
|
SPMTYP |
string(20) |
Type of space world as enumerated |
|
|
SPMVOI |
integer |
Space void marker |
|
|
SPOONUMBER |
string(120) |
Spool number including spool prefix |
|
|
SPOW |
element |
Reference of SPEC owning SPCO of branch members |
|
|
SPPOSN |
integer |
Position number of spigot plate |
|
|
SPPURP |
word |
Special purpose table attribute |
|
|
SPRA |
real |
word |
Spec angle answer |
|
SPRB |
real |
word |
Spec bore answer |
|
SPRE |
element |
Component spec reference |
|
|
SPSF |
element |
Sheet pointset reference |
|
|
SPSP |
string(2) |
Old spooler spool prefix |
|
|
SPTYPE |
word |
Type of element to be selected |
|
|
SPWD |
string |
word |
Spec text answer |
|
SQCURR |
integer |
Current value in sequence |
|
|
SQMAX |
integer |
Maximum value of sequence |
|
|
SQNAME |
string(50) |
Name of sequence |
|
|
SQSTEP |
integer |
Increments in sequence |
|
|
SQWRAP |
logical |
True if wrap around in sequence is allowed |
|
|
SREF |
string(12) |
Source reference |
|
|
SREL |
integer |
Start releases (packed) |
|
|
SREVAY |
element(50) |
Sheet revisions array |
|
|
SRFTRE |
element |
Reference to a SRFTRT element |
|
|
SRTP |
integer |
Sorting priority for dimensions |
|
|
SSLENGTH |
real |
Second side length |
|
|
SSPLIT |
logical |
Spool Split |
|
|
STACOM |
string(1000) |
Comment to the current status set |
|
|
STAELE |
real |
Start Elevation |
|
|
STAN |
real |
Start angle |
|
|
STAP |
real |
Length of arrive straight tube |
|
|
STAPOINT |
integer |
Cable Start connection point |
|
|
STAREF |
element |
Cable Start reference |
|
|
STASUS |
logical |
Current status suspended |
|
|
STCD |
string(100) |
Symbol Code |
|
|
STDEFREF |
element |
Status definition |
|
|
STEREF |
element(500) |
Stencil reference array for schematic elements |
|
|
STEX |
string(120) |
S Text string |
|
|
STFC |
real |
Constant stretch factor |
|
|
STFP |
real |
Proportional stretch factor |
|
|
STINCD |
string(120) |
Inside surface treatment symbol code |
|
|
STINRF |
element |
Inside surface treatment reference |
|
|
STITL |
string(120) |
Sheet title |
|
|
STLE |
real |
Length of leave straight tube |
|
|
STLPOS |
element |
Status Element reference |
|
|
STLR |
element |
Steel Reference |
|
|
STLSF |
element |
Database reference |
|
|
STMF |
element |
Template selection pointer |
|
|
STOCKL |
real |
Stock Length |
|
|
STOUCD |
string(120) |
Outside Surface treatment symbol code |
|
|
STOURF |
element |
Outside surface treatment reference |
|
|
STPDBS |
element(5000) |
Stamps containing db |
|
|
STPSES |
integer(2000) |
Sessions used in at least one stamp |
|
|
STPUV |
pos |
Start point |
|
|
STRCON |
string(120) |
Stair Configuration |
|
|
STRE |
real |
Spot value of stress |
|
|
STREAT |
string(26) |
Surface treatment |
|
|
STREV |
string(120) |
String value evaluation |
|
|
STRSTD |
string(120) |
Stair Standard |
|
|
STRXP |
integer(500) |
String expression |
|
|
STRXPL |
logical |
True if surface treatment explicitly defined |
|
|
STSESS |
integer |
Database session number |
|
|
STSP |
element |
Structural specification |
|
|
STVASD |
element(500) |
Status types eligible |
|
|
STVCOM |
string |
element |
Status comment |
|
STVDEMOTE |
element |
Demote Status Value |
|
|
STVDSC |
string |
element |
Status description |
|
STVHCO |
string |
element |
Status held comment |
|
STVHOL |
logical |
element |
Current status held |
|
STVLNK |
element |
element |
Status value Reference |
|
STVLSK |
element(500) |
Status Link Elements |
|
|
STVLST |
element(500) |
Statuses assigned |
|
|
STVNAM |
string |
element |
Status value name |
|
STVNUM |
integer |
element |
Status value |
|
STVPROMOTE |
element |
Promote Status Value |
|
|
STVREF |
element |
Value Ref |
|
|
STVSUS |
logical |
element |
Current status held |
|
STVTRV |
element(500) |
Valid Transitions |
|
|
STVUNR |
element(500) |
Unresolved Status refs |
|
|
STVUSD |
element(10000) |
Elements having this status value |
|
|
STVVAL |
element |
element |
Status value Reference |
|
STYF |
element |
Rep style reference |
|
|
STYP |
string |
SPECON type question |
|
|
STYPDB |
string |
DB sub type |
|
|
SUFFIX |
string(120) |
Suffix |
|
|
SUPP |
string(120) |
Supplier Name |
|
|
SUPR |
element |
SUPREF |
|
|
SURF |
string(120) |
Surface Preparation |
|
|
SURMAT |
string(100) |
Surface Material |
|
|
SURNOR |
dir |
pos, dir |
Surface Normal |
|
SURPNT |
pos |
pos, dir |
Surface Point |
|
SURPRE |
string(100) |
Surface Preparation |
|
|
SVASPLANE |
logical |
Hull symbolic view as plane Y/N |
|
|
SVASSEMBLIES |
element(100) |
Hull symbolic view assembly elements |
|
|
SVAUTO |
logical |
Hull symbolic view auto Y/N |
|
|
SVBLEXCLUDE |
logical |
Hull symbolic view exclude blocks Y/N |
|
|
SVBLOCKS |
element(100) |
Hull symbolic view block elements |
|
|
SVCAX |
logical |
Hull symbolic view coord axis Y/N |
|
|
SVCOMNO |
integer |
Hull symbolic view component number |
|
|
SVCOMTYPE |
integer |
Hull symbolic view component type |
|
|
SVCROSSSYM |
logical |
Hull symbolic view cross sect symbol Y/N |
|
|
SVCURTYPE |
integer |
Hull symbolic view curve type |
|
|
SVCURVES |
element(100) |
Hull symbolic view curve elements |
|
|
SVDBEFORE |
string(20) |
Hull symbolic view depth before |
|
|
SVDBEHIND |
string(20) |
Hull symbolic view depth behind |
|
|
SVDRACCOM |
logical |
Hull symbolic view draw accommodation Y/N |
|
|
SVDRAINTERS |
logical |
Hull symbolic view draw inters Y/N |
|
|
SVDRAP |
logical |
Hull symbolic view draw plane V |
|
|
SVDRCWAY |
logical |
Hull symbolic view draw cableway Y/N |
|
|
SVDREQUIP |
logical |
Hull symbolic view draw equip Y/N |
|
|
SVDRPIPE |
logical |
Hull symbolic view draw pipe Y/N |
|
|
SVDRPVOL |
logical |
Hull symbolic view draw pvol Y/N |
|
|
SVDRSTRUCT |
logical |
Hull symbolic view draw structure Y/N |
|
|
SVDRVENT |
logical |
Hull symbolic view draw ventilation Y/N |
|
|
SVLOOKING |
integer |
Hull symbolic view looking direction |
|
|
SVLXMAX |
string(20) |
Hull symbolic view xmax |
|
|
SVLXMIN |
string(20) |
Hull symbolic view xmin |
|
|
SVLYMAX |
string(20) |
Hull symbolic view ymax |
|
|
SVLYMIN |
string(20) |
Hull symbolic view ymin |
|
|
SVLZMAX |
string(20) |
Hull symbolic view zmax |
|
|
SVLZMIN |
string(20) |
Hull symbolic view zmin |
|
|
SVNAME |
string(1000) |
Hull symbolic view name |
|
|
SVPANELS |
element(100) |
Hull symbolic view panel elements |
|
|
SVPLEXCLUDE |
logical |
Hull symbolic view exclude panels Y/N |
|
|
SVPLTYPE |
integer |
Hull symbolic view plane type |
|
|
SVPLXORIGIN |
string(20) |
Hull symbolic view x1 |
|
|
SVPLXUAXIS |
string(20) |
Hull symbolic view x2 |
|
|
SVPLXVAXIS |
string(20) |
Hull symbolic view x3 |
|
|
SVPLYORIGIN |
string(20) |
Hull symbolic view y1 |
|
|
SVPLYUAXIS |
string(20) |
Hull symbolic view y2 |
|
|
SVPLYVAXIS |
string(20) |
Hull symbolic view y3 |
|
|
SVPLZORIGIN |
string(20) |
Hull symbolic view z1 |
|
|
SVPLZUAXIS |
string(20) |
Hull symbolic view z2 |
|
|
SVPLZVAXIS |
string(20) |
Hull symbolic view z3 |
|
|
SVPNAM |
string(1000) |
Hull symbolic view pan name |
|
|
SVPONLY |
logical |
Hull symbolic view pan only |
|
|
SVPOSCOAXIS |
string(20) |
Hull symbolic view coord axis pos |
|
|
SVREFLECT |
logical |
Hull symbolic view reflect Y/N |
|
|
SVRSO |
logical |
Hull symbolic view RSO Y/N |
|
|
SVSCALE |
real |
Hull symbolic view scale |
|
|
SVSHPROFILE |
logical |
Hull symbolic view profile Y/N |
|
|
SVSHSEAM |
logical |
Hull symbolic view shell seam Y/N |
|
|
SVSHTHICK |
logical |
Hull symbolic view shell thickness Y/N |
|
|
SVTYPE |
integer |
Hull symbolic view type |
|
|
SVWAY |
element(50) |
Sheet Views array |
|
|
SWING |
word |
Swing |
|
|
SYLBTA |
word |
SYLBTAble attribute |
|
|
SYMBFG |
logical |
Symbol flag |
|
|
SYMELE |
element |
Reference to element on other side of CL (unset for non-symmetric) |
|
|
SYMGRO |
string(120) |
Symbol Group |
|
|
SYMLNS |
integer |
Side of direction vector |
|
|
SYMM |
integer |
Symmetry code |
|
|
SYMNAM |
string(120) |
Symbol Name |
|
|
SYMXYZ |
dir |
Vector along symmetry line |
|
|
SYSZ |
real |
Symbol size (uniform scaling) |
|
|
SYTBOK |
logical |
SYLBTA attribute updated flag |
|
|
SZDI |
real |
Start load point in section |
|
|
TABANS |
real(10) |
Tabular answers |
|
|
TAGCD |
integer |
Tag code |
|
|
TAGCDS |
integer(25) |
Tag codes |
|
|
TAGNMS |
integer(25) |
Tag numbers |
|
|
TAGNUM |
integer |
Tag number |
|
|
TANGLE |
real |
Tile Angle |
|
|
TANGOF |
real |
Tangent offset |
|
|
TANS |
string(1024) |
Text answer for text styp in spec |
|
|
TARF |
element |
Target reference |
|
|
TATYPE |
string(10) |
Text answer type |
|
|
TBID |
integer |
Tribon ID |
|
|
TBNAME |
string(25) |
TbName |
|
|
TBOR |
real |
Tail bore |
|
|
TCAT |
element |
Trace catalogue reference |
|
|
TCDD |
string(250) |
word |
Current design property default value |
|
TCDP |
string(250) |
word |
Current design property value |
|
TCOD |
string |
Hashed origin code |
|
|
TCON |
word |
Tail connection type |
|
|
TCORRO |
real |
Tail Corrosion |
|
|
TCREF |
element(10) |
Tail connections |
|
|
TCTL |
real |
True cut length |
|
|
TDEF |
string(1024) |
Text default for text styp in spec |
|
|
TDET |
element |
Trace detail text reference |
|
|
TDIR |
dir |
Tail direction |
|
|
TDMF |
element(2) |
ISODRAFT Reference Dimension attribute |
|
|
TDMT |
word(2) |
ISODRAFT Reference Dimension attribute |
|
|
TDPR |
real |
word |
Template design dataset property |
|
TDRT |
string(2000) |
Trace detail RTEXT |
|
|
TDST |
string(2000) |
Trace detail STEXT |
|
|
TDTT |
string(2000) |
Trace detail TTEXT |
|
|
TEAMLS |
element(1000) |
List of TEAMs to which USER belongs |
|
|
TEASTA |
word |
Access Control team status |
|
|
TEMF |
element |
Team reference |
|
|
TEMP |
real |
Temperature |
|
|
TEND |
string |
Connection at other end of TREF (HEAD or TAIL) |
|
|
TEQDES |
string(120) |
To Equipment Description |
|
|
TESTEV |
logical |
Result of constraint test evaluation |
|
|
TESTXP |
integer(500) |
Logical Expression |
|
|
TEXIST |
logical |
True if component has TUBI. Always true for offline bends. |
|
|
TFDP |
element |
word |
Template design dataset property |
|
TGEOM |
logical |
True if component has TUBI geometry |
|
|
TGRA |
real |
Pipework temperature gradient |
|
|
THERMA |
string(104) |
Thermal category |
|
|
THICKNESS |
real |
Thickness |
|
|
THPO |
pos |
Point through which viewing |
|
|
TIERHE |
real(15) |
Heights of trays measured from path |
|
|
TIMEEND |
integer |
End time of COMMS window |
|
|
TIMEINTERVAL |
integer |
COMMS retry time interval |
|
|
TIMEOUTNUMBER |
integer |
COMMS max retry count |
|
|
TIMER |
string(120) |
Frequency of DB propagation |
|
|
TIMESTART |
integer |
Start time of COMMS window |
|
|
TIMFAC |
real |
Pathtime time factor |
|
|
TIMPET |
string(15) |
Time factor pre text |
|
|
TIMPOT |
string(15) |
Time factor post text |
|
|
TITL |
string(1000) |
Title |
|
|
TLCONN |
element(500) |
List of elements connected to branch tail |
|
|
TLIN |
logical |
True length indicator |
|
|
TLREF |
element(500) |
List of attachment connected to attachment |
|
|
TMAT |
element |
Trace material text reference |
|
|
TMAV |
real |
Average temperature |
|
|
TMDWG |
string(120) |
AutoCAD template name |
|
|
TMMA |
real |
Maximum temperature |
|
|
TMMI |
real |
Minimum temperature |
|
|
TMPR |
element |
Template reference from SPCO |
|
|
TMRF |
element |
Template reference |
|
|
TMRMASTER |
element |
Template Repeat Master Duplicate Element |
|
|
TMROWNER |
element |
Template Repeat Owning Element |
|
|
TMRREF |
element |
Template Repeat Element Reference |
|
|
TMRRULE |
integer(500) |
Template Repeat Rule |
|
|
TMRXREF |
element(500) |
Return reference from TMRREL element to repeat elements |
|
|
TMXT |
string(2000) |
Trace material XTEXT |
|
|
TMYT |
string(2000) |
Trace material YTEXT |
|
|
TMZT |
string(2000) |
Trace material ZTEXT |
|
|
TOFFT |
real |
Tail offset |
|
|
TOPOLOGY |
string(120) |
Branch topology |
|
|
TOTALT |
real |
Total machine time for a nested plate |
|
|
TOTLAB |
real |
Total label pathtime |
|
|
TOTLEN |
real |
Total manual length |
|
|
TOTT |
real(2) |
Total pathtime |
|
|
TOTTI |
real(2) |
Total pathtime, I-bevel |
|
|
TOTTX |
real(2) |
Total pathtime, X-bevel |
|
|
TOTTY |
real(2) |
Total pathtime, Y-bevel |
|
|
TPAR |
real(30) |
Trace catalogue component parameters |
|
|
TPEN |
integer |
Text pen |
|
|
TPLFRR |
element(10000) |
Topology references |
|
|
TPON |
integer |
TO port number |
|
|
TPOS |
pos |
Tail position |
|
|
TPOSE |
real |
Easting of tail position |
|
|
TPOSN |
real |
Northing of tail position |
|
|
TPOSU |
real |
Upping of tail position |
|
|
TPREF |
element |
Tail point reference |
|
|
TPRESS |
real |
TestPressure |
|
|
TPVAL |
string(1000) |
Task parameter name |
|
|
TQUAL |
string(1024) |
Text qualifier in spec or sele |
|
|
TQUES |
string(1024) |
Text question in spec or sele |
|
|
TRANS |
real(12) |
Local transformation matrix |
|
|
TRAYH |
real |
Tray height |
|
|
TRAYOW |
real |
Tray other width |
|
|
TRAYRW |
real |
Tray Reduce Width |
|
|
TRAYSW |
real |
Tray side width |
|
|
TRAYW |
real |
Tray Width |
|
|
TRCG |
logical |
DRAFT user defined symbol trace flag |
|
|
TRCLIN |
word |
Trace line |
|
|
TREATP |
element |
Tread type |
|
|
TREDOV |
real |
Tread Overlap |
|
|
TREF |
element |
Tail reference |
|
|
TRGENA |
logical |
Initial Value |
|
|
TRIMCE |
integer(10000) |
Array of Trimmed Cells |
|
|
TRIMTY |
word |
CTWALL TRIM TYPE |
|
|
TRSF |
element |
Tag ruleset reference |
|
|
TRUN |
real |
Truncation value (+ve) or percentage (-ve) |
|
|
TSFBR |
logical |
Spooling marker for leave tube |
|
|
TSIZ |
real |
Terminator size |
|
|
TSLEN |
real |
Total suspension length |
|
|
TSPE |
element |
Tracing spec reference |
|
|
TSPR |
element |
Trace specification component reference |
|
|
TTEX |
string(2000) |
T Text string |
|
|
TTFACE |
string(32) |
TrueType font face name |
|
|
TTFDES |
string(128) |
TrueType font description |
|
|
TTFENA |
logical |
TrueType fonts enabled flag |
|
|
TTFIND |
integer |
TrueType font index |
|
|
TTYP |
word |
Template type |
|
|
TUCL |
real |
Tube centreline length of branch |
|
|
TUFG |
logical |
Tubing flag |
|
|
TUFL |
logical |
Tube flag |
|
|
TULE |
real |
Tube length of branch |
|
|
TVIS |
logical |
Top visibility flag |
|
|
TWALLT |
real |
Tail wall thickness |
|
|
TWIDTH |
real |
Tread Width |
|
|
TWIST |
logical |
True if twisted |
|
|
TWLEN |
real |
Total weld length |
|
|
TWRF |
element |
Tail Working Point (Router) |
|
|
TWSTAN |
real |
Twist angle |
|
|
TXALIGN |
string |
Text alignment |
|
|
TXAREA |
real |
Total Cableway X-area |
|
|
TXCOLO |
integer |
Text colour |
|
|
TXCONU |
integer |
Text colour number |
|
|
TXSPLI |
logical |
Text splitting flag |
|
|
TXSTRI |
string(1000) |
Text String for enhanced LineStyles |
|
|
TYNU |
integer |
Number type |
|
|
TYPE |
word |
Type of the element, ignoring UDET, truncated to 4 or 6 characters |
|
|
TYPEA |
string(10) |
TYPEA |
|
|
TYPEB |
string(10) |
TYPEB |
|
|
TYPECD |
integer |
Type code |
|
|
TYPECE |
integer |
Type code |
|
|
TYPEDB |
string(6) |
DB type |
|
|
TYPEXPRESSION |
string(4000) |
Type Expression |
|
|
TYPEXTYPE |
string(60) |
Type expression type |
|
|
TYPINC |
logical |
Type is inclusive |
|
|
TYSEQU |
integer |
Type Sequence Number |
|
|
U |
real |
Position upping |
|
|
UAEXSS |
real |
User Excess Arrive |
|
|
UALL |
logical |
UALL |
|
|
UAREA |
real |
Used area |
|
|
UBULG |
real |
Used bulge factor for curve geometry |
|
|
UCAT |
string(50) |
Category on forms |
|
|
UCOD |
integer |
Units code |
|
|
UCODB |
integer |
Units code bore |
|
|
UCODD |
integer |
Units code distance |
|
|
UCONN |
logical |
True if the UDA value should appear on the reference list form |
|
|
UCURTYP |
word |
Used curve type |
|
|
UCUTDI |
dir |
Upper Extension Cutting Direction |
|
|
UDACPY |
element |
UDA copy |
|
|
UDALIS |
word(2000) |
List of UDAs |
|
|
UDASET |
word(2000) |
List of UDAs set |
|
|
UDATLS |
word(200) |
List of attributes for UDET |
|
|
UDETCHECK |
string(120) |
Report from UDET check on element |
|
|
UDHLIST |
word(200) |
Attributes hidden on elements of this user-defined element type |
|
|
UDIRECTION |
dir |
Up axis direction |
|
|
UDMLIST |
word(200) |
List of allowed member types |
|
|
UDNA |
string(50) |
User defined name |
|
|
UDOLIST |
word(200) |
List of allowed owner types |
|
|
UDPEND |
word(200) |
list of attributes that this attribute depends on |
|
|
UEEXSS |
real |
User End Excess |
|
|
UEXTNS |
real |
Upper Extension Length |
|
|
UGOING |
real(10) |
Upper Tread Going |
|
|
UHIDE |
logical |
Set true to hide attribute on forms |
|
|
UHYPER |
logical |
Set true to treat attribute value as a named link to an external resource |
|
|
UIWE |
string(1000) |
Unit insulation weight |
|
|
UKEY |
integer |
UDA key - internal unique system identifier |
|
|
ULEN |
integer |
Length of data or text |
|
|
ULVOPT |
logical |
Determines if UDA valid values or range limit is optional |
|
|
UMAX |
real |
Maximum value |
|
|
UMIN |
real |
Minimum value |
|
|
UNAM |
string(12) |
Name of user |
|
|
UNDERL |
logical |
Underling flag |
|
|
UPDCB |
string(500) |
ADP update callback |
|
|
UPLLEN |
real |
Used raw plate length |
|
|
UPPING |
pos |
Upping part expressed as a position |
|
|
UPPREF |
element |
References to upper exit level |
|
|
UPRLEN |
real |
Raw profile used length |
|
|
UPROTE |
logical |
Set true to disallow viewing the attribute in a protected database |
|
|
UPSEUD |
logical |
Set true to calculate attribute value rather than store it in a database. User code must be provided |
|
|
URADI |
real |
Used radius for curve geometry |
|
|
UREF |
element |
Units reference |
|
|
URISE |
real(10) |
Upper Tread Rise |
|
|
URL |
string(1024) |
URL |
|
|
USCCOG |
pos |
User derived centre of gravity position |
|
|
USCLHI |
element(5000) |
Elements in descendant hierarchy claimed to this user |
|
|
USCWCO |
pos |
User derived wet centre of gravity position |
|
|
USCWEI |
real |
Derived value for user weight |
|
|
USCWWE |
real |
Derived value for user wet weight |
|
|
USEF |
element |
User reference |
|
|
USERC |
string(120) |
User name of user claiming element |
|
|
USERLS |
element(1000) |
List of USERs belonging to TEAM |
|
|
USERM |
string(120) |
attr |
User making last modification |
|
USESS |
string(120) |
integer |
User creating session |
|
USNCLH |
element(5000) |
Elements in descendant hierarchy not claimed to this user |
|
|
USRCOG |
integer(500) |
User centre of gravity position |
|
|
USRLI |
element(50) |
Valid users for given user login |
|
|
USRWCO |
integer(500) |
User wet centre of gravity position |
|
|
USRWEI |
integer(500) |
User entered weight value |
|
|
USRWWE |
integer(500) |
User entered wet weight value |
|
|
USYSTY |
word |
Name of the system attribute |
|
|
UTEAMS |
element(200) |
Teams that will see a hidden attribute |
|
|
UTYP |
word |
Type of attribute value |
|
|
UUID |
string(36) |
Universally unique identifier |
|
|
UUIDAR |
integer(4) |
Universally unique identifier, stored array |
|
|
UUIDREF |
element(500) |
word |
Universally unique identifier references |
|
UUNI |
string(20) |
Units of attribute values (bore/distance/text) |
|
|
UVVAL |
string(500) |
Valid value for UDA |
|
|
UWEI |
string(1000) |
Unit pipe weight |
|
|
UWGHT |
real |
Used weight |
|
|
UWIDTH |
real |
Used width |
|
|
UWMTXT |
string(120) |
User weight Manager text |
|
|
UWP |
pos |
Upper Working Point |
|
|
VALARR |
element(50) |
Valid Status Values |
|
|
VALIDV |
string(1000) |
Valid value expression for VVALUE elements |
|
|
VALNAM |
string(50) |
Local Name of a Status Value |
|
|
VALNUM |
integer |
Numerical representation of a Status Value |
|
|
VALREF |
element |
Status Value reference |
|
|
VALRUL |
string(1000) |
Valid rule expression to test VALIDV attributes of VVALUE elements |
|
|
VALTEX |
string(120) |
Textual representation of a Status Value |
|
|
VANGLE |
real |
Angle from vertical |
|
|
VBEVEL |
logical |
True if part has bevel type V |
|
|
VCOMPD |
string(50) |
View Comparison Date |
|
|
VCOMPS |
element |
View Comparison Stamp |
|
|
VDISTA |
real |
Vertical Distance |
|
|
VDPOS |
pos |
Dimension line/arc position |
|
|
VDTINT |
integer(2) |
Verification date |
|
|
VDTTXT |
string(22) |
Verification date text |
|
|
VENID |
string(120) |
LMI Vendor ID |
|
|
VERTDI |
logical |
VERTDI (true if Z axe is vertical ) |
|
|
VGAP |
real |
View gap length |
|
|
VHEIGHT |
real |
Volume height |
|
|
VIRF |
logical |
Virtual Flag |
|
|
VISF |
string(73) |
Visio filename |
|
|
VLIM |
real(6) |
View limits |
|
|
VMAR |
real |
ADP view margins |
|
|
VMCIAR |
integer(10) |
VM Component Int Array |
|
|
VMCRAR |
real(10) |
VM Component Real Array |
|
|
VMDRPDMS |
logical |
VM Draw anno using pdms engine Y/N |
|
|
VMFCFB |
logical |
VM Fill Colour From Border Y/N |
|
|
VMFLAY |
integer |
VM Fillstyle Layer |
|
|
VMGLAY |
integer |
VM Geometry Layer |
|
|
VMTASP |
real |
VM text aspect |
|
|
VMTSLA |
real |
VM text slant (degrees) |
|
|
VMUSYS |
integer |
VM Fillstyle Unit System |
|
|
VNREF |
element |
VNOTE reference - special attribute for use by ADP |
|
|
VOLTAC |
string(1000) |
Voltage AC |
|
|
VOLTDC |
string(1000) |
Voltage DC |
|
|
VRADI |
real |
Cableway radius |
|
|
VRAT |
real(2) |
View ratio |
|
|
VREG |
real(4) |
View region |
|
|
VSCA |
real |
Viewing scale - scales projected view |
|
|
VSHAPE |
integer |
Volume shape |
|
|
VTITL |
string(120) |
View title |
|
|
VTYP |
string |
Type of design view |
|
|
VVOL |
real(6) |
View volume |
|
|
VWIDT |
real |
Volume width |
|
|
VWLIMI |
real(6) |
View Limits - special attribute for use by ADP |
|
|
VWREFA |
element(20) |
View reference array - special attribute for use by ADP |
|
|
VXREF |
element(500) |
Vertex reference array |
|
|
W |
real |
Position westing |
|
|
WALLTH |
real |
Tube wall thickness |
|
|
WAMA |
real |
Maximum water level |
|
|
WANS |
word(100) |
Word answers |
|
|
WATERT |
logical |
Water Tight |
|
|
WATTIM |
real |
Water cleaning time |
|
|
WBORE |
real |
Bore on IWELD/RWELD |
|
|
WCANG |
real |
Weld connection angle |
|
|
WCOM |
string(26) |
Weld comment |
|
|
WDBNA |
string |
Working DB name |
|
|
WDESP |
word(100) |
Design parameters as words |
|
|
WDIA |
string(1000) |
Wind diameter modulus |
|
|
WEFA |
real |
Weight multiplier |
|
|
WEIG |
real(3) |
Weighting value |
|
|
WELDDP |
real |
Welding depth |
|
|
WELDMC |
element |
Welding Machine Reference |
|
|
WESUSP |
real |
Weld end suspension |
|
|
WHOLEC |
real |
Array of Whole Cells |
|
|
WIANG |
real |
Weld inclination angle |
|
|
WIDARR |
real(10) |
Width array |
|
|
WIDT |
real |
Width |
|
|
WIFA |
real |
Wind multiplier |
|
|
WJPOS |
pos |
Implied weld position |
|
|
WJUSL |
word |
Wall Justification Line |
|
|
WLDC |
integer |
Weld Code |
|
|
WLDN |
integer |
Weld number |
|
|
WLDP |
string(4) |
Weld number prefix |
|
|
WLDPOS |
string(26) |
Welding position |
|
|
WLDREF |
element |
integer |
Return reference from Ppoint or WELD to IWELD or RWELD element |
|
WLEGL |
real |
Weld leg length |
|
|
WLEN |
real |
Weld length |
|
|
WMAX |
integer |
Maximum weld number in current spool drawing |
|
|
WNAM |
string(26) |
Weld name |
|
|
WNLAY |
integer |
Number of weld layers |
|
|
WORI |
ori |
World orientation |
|
|
WORPOS |
pos |
World position |
|
|
WPAR |
word(100) |
Parameters as a word |
|
|
WPRE |
real |
Wind pressure |
|
|
WPROC |
string(26) |
Welding process |
|
|
WRANG |
real |
Weld rotation angle |
|
|
WSHOP |
logical |
Weld shop/site flag on IWELD/RWELD |
|
|
WSPEC |
element |
Weld specification on IWELD/RWELD |
|
|
WSPROC |
string(26) |
Welding standard process |
|
|
WSSUSP |
real |
Weld start suspension |
|
|
WTCOM |
string(300) |
Weld table comment |
|
|
WTEREF |
element |
integer |
Wall thickness element reference |
|
WTHICK |
real |
Wall thickness |
|
|
WTHREF |
element |
Wall thickness table reference |
|
|
WTOL |
string(1000) |
Wall thickness tolerance / Weight tolerance |
|
|
WTORCH |
dir |
Weld torch vector |
|
|
WTPROC |
string(26) |
Welding test procedure |
|
|
WTRANS |
real(12) |
Transformation matrix to world |
|
|
WTSTAT |
string(26) |
Weld table status |
|
|
WVOL |
real(6) |
Enclosing box volume in world coordinates |
|
|
XAMANG |
real |
Cross section along mounting angle |
|
|
XAREA |
string(1000) |
Cross sectional area |
|
|
XBEVEL |
logical |
True if part has bevel type X |
|
|
XBOT |
real |
Bottom X length |
|
|
XBSH |
real |
X bottom shear: inclination of bottom face to local X axis |
|
|
XFTPT |
pos |
Cross section foot point |
|
|
XINCL |
real |
Cross section inclination angle |
|
|
XLEN |
real |
X length |
|
|
XOFF |
real |
X-offset |
|
|
XRLIST |
element(10000) |
elemtype |
List distributed attributes |
|
XRLSTT |
word(2000) |
elemtype |
List distributed attributes |
|
XRPNTR |
element |
Distributed Attributes reference |
|
|
XRQCNT |
integer |
elemtype |
Get distributed attributes element count |
|
XRQELE |
element |
elemtype, integer |
Get distributed attributes element |
|
XRSTRT |
element |
Distributed Attributes reference |
|
|
XTEX |
string(2000) |
X text |
|
|
XTHK |
real |
Cross section thickness |
|
|
XTOP |
real |
Top X length |
|
|
XTPPT |
pos |
Cross section top point |
|
|
XTRA |
real |
Extra length requirement for BOLTS |
|
|
XTSH |
real |
X top shear: inclination of top face to local X axis |
|
|
XXMANG |
real |
Cross section cross mounting angle |
|
|
XXXDIR |
dir |
Direction Test attribute |
|
|
XXXORI |
ori |
Orientation Test attribute |
|
|
XXXPOS |
pos |
Position Test attribute |
|
|
XYOFFS |
real(2) |
XY offset |
|
|
XYPS |
pos |
2D Position |
|
|
XYSC |
real(2) |
Label XY size |
|
|
YBEVEL |
logical |
True if part has bevel type Y |
|
|
YBOT |
real |
Bottom Y length |
|
|
YBSH |
real |
Y bottom shear: inclination of bottom face to local Y axis |
|
|
YDIR |
dir |
Preferred Y axis direction |
|
|
YLEN |
real |
Y length |
|
|
YOFF |
real |
Y-offset |
|
|
YOUN |
real |
Spot value of Youngs modulus |
|
|
YTEX |
string(2000) |
Y text |
|
|
YTOP |
real |
Top Y length |
|
|
YTSH |
real |
Y top shear: inclination of top face to local Y axis |
|
|
ZDIR |
dir |
Additional axis direction |
|
|
ZDIS |
real |
Position in section |
|
|
ZLEN |
real |
Z length |
|
|
ZOFF |
real |
Z-offset |
|
|
ZTEX |
string(2000) |
Z text |