Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

Hull and Outfitting

List of All Attributes

  • Last UpdatedFeb 09, 2023
  • 68 minute read

Attribute Name

Data Type

Qualifier

Description

AALLAN

real

Arrive Ppoint allowed angle

AANGXZ

real

Angle of attached SCTN in XZ plane of joint

AANGYZ

real

Angle of attached SCTN in YZ plane of joint

ABLE

integer

Minimum abbreviation length for a UDA/UDET user defined name

ABOP

pos

Bottom of arrive pipe

ABOR

real

Arrive bore

ABRE

string(8)

Abbreviation

ACBO

string(1000)

Actual bore

ACCDIR

dir

Access Direction

ACCELE

real(500)

Elevations of Referenced Levels

ACCESSDB

string(10)

DB access

ACCIDENT

real

Accident level radiation

ACCLEV

real(500)

Access Heights for Stairwell

ACCREF

element

Reference to Access element

ACCTYP

word

Access type

ACDATE

string(50)

Date last modified in AutoCAD

ACDSTY

string(120)

AutoCAD Dimension style

ACDWT

string(120)

AutoCAD drawing template name

ACEXPO

string

AutoCAD export flag

ACLASS

word(100)

Access Control Attribute class

ACLAYE

string(120)

AutoCAD layer name

ACLIST

element(500)

Arriving cables to attached point

ACLOCK

string

AutoCAD picture lock

ACNAME

string(120)

AutoCAD name

ACON

word

Arrive connection type

ACORRO

real

Arrive corrosion allowance

ACPICT

string

AutoCAD picture flag

ACPO

element

Access port reference

ACRF

element

ACR reference attribute

ACRGRP

element(5000)

List of ACRs within a ACRSET

ACRLI

element(1000)

Access Control User assigned ACRs

ACRMESSAGE

string(120)

Access Control User defined message

ACSCAL

real

AutoCAD picture scale factor

ACSTYF

element

Annotation change style reference

ACTANG

real

Actual angle of a bend

ACTL

real

Actual length

ACTNCU

integer

Actual number of cuts of a bend

ACTRAD

real

Actual radius of a bend

ACTTYPE

word

Type of element, truncating non UDETs to 4 or 6 characters

ADDSEGMENTS

logical

Auto creating segments flag

ADEFRF

element

Reference to master ASSDEF

ADEG

real

Orientation

ADEN

real

Addition factor (unit definition)

ADESP

real(100)

Design parameters of attached element

ADIR

dir

Arrive direction

ADMLOC

element

Currently administered location

ADPRFA

element(500)

ADP reference array

ADUUID

string(40)

PDMS Project GLOBAL UUID version string

AELRFA

element(500)

Boundary components for the PipePiece

AGRD

real

Arrive Ppoint gradient

AHLIS

word(200)

List of actual types in owning hierarchy

AIRCHA

real

Air Change Rate

AIRT

string(120)

Air tight control method

AKEY

word

Attribute key

AKEYL

word(20)

Attribute-keylist (for Radial dimensions)

ALCODE

integer(10)

Alarm code array

ALENGTH

real

Arrive length

ALIGN

string

Vertical alignment

ALIST

element(500)

ALLANG

string(1000)

Connection allowable rotational angle

ALLELE

element(10000)

elemtype

All elements in the MDB of a particular type

ALLO

real

Allowance

ALTDEF

element

Alternative Def

AMAPNM

string(120)

Local Name of Proxy actual member

AMEMRF

element

Reference to a design model object

AMPMPN

string(120)

Local Name of Proxy in Association

ANGFR

real

Angle between assembly and frame plane

ANGL

real

Angle

ANGLSP

real(10000)

ANGLE Spacing

ANGSPA

real

Springback angle at 20 degrees

ANGSPB

real

Springback angle at 120 degrees

ANGWL

real

Angle between assembly and water-line plane

ANPJ

pos

Attached neutral point of joint (steelwork)

ANPS

pos

Attached neutral point of section (steelwork)

ANSTYP

word

Type of answer NONE, REAL, WORD, TEXT or BOOL

ANSW

real

Answer, when a real is expected

ANTY

string(120)

Analysis type

ANYCHA

logical

True if chamfer is defined on any edge

AOBJS

element(500)

Reference Array of all Model currently participating in ASSOCs

AOD

real

Arrive Ppoint outside diameter

APAR

real(100)

Attached catalogue parameters

APARMS

real(9)

All parameters

APDT

string(12)

Date of approval

APOF

real(2)

Leaderline attachment point

APOS

pos

Arrive position

APOSE

real

Easting of arrive position

APOSN

real

Northing of arrive position

APOSU

real

Upping of arrive position

APPL

string(20)

Application

APPR

string(1000)

Approver

APRO

real

Spot value of property A

AQAANG

real

Angle between alignment direction of arrive pp and previous

AQANG

real

Angle between arrive Ppoint and previous component

AQBORE

logical

TRUE if arrive Ppoint has same bore as previous

AQCON

logical

TRUE if arrive Ppoint has Correct connection type

AQOFF

real

Offset between arrive Ppoint and previous component

AREA

integer

Area

AREAEX

logical

True if area exists for DB

AREARE

element

Area reference

ARNO

integer

Picture directory area number

ARRHEI

real

Arrive height

ARRI

integer

Arrive Ppoint

ARRWID

real

Arrive width

ASBPAN

element

Assembly base panel reference

ASBUIL

string(1000)

Assembly build strategy

ASCODE

string

Anno selection code

ASDEST

string(120)

Assembly destination

ASECOG

real(3)

Assembly estimated centre of gravity

ASEWEI

real

Assembly estimated weight

ASIOWN

element(500)

Assembly item referring to element

ASIQUA

integer

Assembly item quantity

ASLSBSTANDARD

element

ASL Substandard Reference

ASLSTANDARD

element

ASL Standard Reference

ASMBLD

logical

True if element is assembled

ASMBLR

element

Assembly reference

ASMBLS

string

A for assembled elements, NA for not assembled elements

ASMBLX

string(120)

Assembly reference as text

ASMBS

element(500)

Reference Array of all association members using element

ASMOWN

element(500)

Assembly referring to element

ASNAME

string(50)

Local assembly name

ASORI

integer

Predefined assembly orientation

ASORIS

string(20)

Predefined assembly orientation string

ASPART

logical

True if assembly part.

ASPLNO

integer

Number of assembly plate parts

ASPRNO

integer

Number of profiles on assembly part

ASPWLE

integer

Total length of weld in assembly part

ASREF

element

Assembly reference

ASRF

element

ADP annotation symbol library ref

ASSCIA

element(500)

Reference Array of all associate elements used with constraints

ASSDFS

element(500)

Reference Array of all ASSDEFs

ASSEQ

integer

Assembly sequence

ASSNTS

element

Reference to assembly nest (valid for individual nest only)

ASSOS

element(500)

Reference Array of all associations with constraints

ASSTAR

element

Association Target Reference

ASSTMPREFERENCE

element

Assembly Template Reference

ASTAB

word(15)

ADP association table

ASTMBS

element(500)

Reference Array of all association members targeting element

ASUB

real

Angle subtended

ASWLOC

string(120)

Assembly working location

ATCONN

element(500)

List of elements connected to attachment

ATCORR

real

Arrive tube corrosion allowance

ATEX

string(1000)

Unintelligent text string

ATLE

real

Length of arrive implied tube

ATLS

word(50)

Access type list

ATNA

word

Attribute name

ATOL

integer

Arc tolerance

ATOP

pos

Top of arrive pipe

ATQUALIFIER

string(4000)

Attribute qualifier

ATTC

word

Attached connection type

ATTDST

word(2000)

List the distributed attributes, default gives all udas

ATTLIST

word(2000)

List of all attributes for element

ATTMOD

logical

attr

True if specified attribute has been modified this session

ATTMODC

logical

attr

True if specified attribute has been modified since comparison date

ATTMODLIST

word(500)

integer

List of attributes modified since given session

ATTMODLISTC

word(500)

List of attributes modified since comparison date

ATTNAM

string(32)

Attribute Name expression for ATTRRL elements

ATTOUT

word(2000)

List of all attributes excluding hidden ones, i.e as output in "Q ATT"

ATTRAW

word(2000)

List of raw attributes

ATTRUL

string(1000)

Attribute Rule expression for ATTRRL elements

ATTSET

word

Set attribute with result

ATTY

word

Attachment type

ATWALL

real

Arrive tube wall thickness

ATWLEN

real

Assembly total weld length

ATWREF

element

Arrive tube wall thickness reference

AUTCOL

real(3)

Design rgb autocolour

AUTCRE

logical

Set true to automatically create bound element.

AUTH

string(1000)

Author

AVRAD

real

Average radius for a CTOR or RTOR

AWALLT

real

Arrive wall thickness

AWDARR

logical

Auto weld arrive flange

AWDFLN

logical

Bending machine accepts autowelded flanges

AWDLEV

logical

Auto weld leave flange

AWDOWN

integer(3)

Table linking AWELD elements to piping components

AWDREF

element(20)

Return reference to AWELD element

AWELDS

integer(20)

Weld numbers of attached welds

AXIDIR

dir

Axis direction applied to repeat

AXIPOS

pos

Axis position applied to repeat

AXSPRI

logical

Is principle Axes Symbol

AXSSIZ

real

AXESYM nominal size

AXSTYP

word

Axes Symbol type

AYDIR

dir

Arrive Y axis direction

AZDIR

dir

Arrive alignment direction

AZID

real

Default Azimuth value

AZIF

real

Azimuth attractor factor

AZIL

real(2)

Azimuth limits (Min/Max)

AZIS

logical

Azimuth set flag - ignore Azimuth values if FALSE

BAEXSS

real

Bending Excess Arrive

BAIN

string

Before/After indicator

BANG

real

Beta angle

BASETYPE

word

Base type for the user-defined element type

BBFF

element(500)

Array of bounding Boundary Formers

BCPY

element

Backward copy reference

BDIA

string(1000)

Bolt diameter

BEAD

real

Default Bearing value

BEAF

real

Bearing attractor factor

BEAL

real(2)

Bearing limits (Min/Max)

BEAS

logical

Bearing set flag - ignore Bearing values if FALSE

BELRFA

element(500)

All components in the PipePiece

BELTYP

integer(500)

All component types in the PipeSpool

BENDCORNERS

logical

Bend corners - true if fillet should be applied to the corners of kickplate

BENDMACREFERENCE

element

Bending Machine reference

BENDMC

element

Bending Machine Reference

BENT

logical

Bent flag

BEVCOD

real(10)

Bevel codes for edges

BEVEL

real

Bevel

BEVFLA

real

Bevel code, flange

BEVLEN

real(2)

Lengths of bevel

BEVLFT

real

Bevel code on left side of seam

BEVLI

real(3)

Lengths of I-bevel

BEVLV

real

Length of vertical bevel

BEVLX

real(3)

Lengths of X-bevel

BEVLY

real(3)

Lengths of Y-bevel

BEVM

real(2)

Bevel codes along M1 and M2 curves

BEVRGT

real

Bevel code on right side of seam

BEVTXT

string

Bevel text

BEVWEB

real

Bevel code, web

BFCOLO

integer

Backface colour

BFCONU

integer

Backface colour number

BFLE

string(1000)

Out of plane flexibility factor for bends

BFPN

integer

Backface pen

BFRF

element

Reference to real Boundary Former

BFSTREF

element

Backface linestyle Reference

BFSTYL

integer

Backface linestyle

BITE

word(25)

Bolt items

BITL

real(25)

Bolt item lengths

BJOINT

string

Bolt joint

BKEY

string(4)

DRAFT user defined base symbol/skey name

BLCKLM

logical

True if block limit seam

BLEN

real(200)

Bolt length

BLEXSS

real

Bending Leave Excess

BLNK

logical

Auto-blanking flag

BLRF

element(10)

Bolt reference array

BLSLEN

real

Length of blasting contours

BLTM

string(3)

Bolt method

BLTR

element

Bolt reference

BMAR

real

Auto-blanking margin

BMAX

integer

Maximum bend number in current spool drawing

BMCLOC

logical

True if bending machine bends clockwise

BMLEVE

real(100)

Beam levels from owning element

BNDARE

real

Boundary line area

BNDOFF

real

Offset from boundary

BOLTPARTNUMBERS

integer(20)

Spooling bolt part numbers

BORE

real

Bore

BOREAR

real(10)

Bore array

BPANOR

ori

Curved base panel orientation

BPANRE

element

Base panel reference

BPOF

real(4)

Leader bend point offset

BPRO

real

Spot value of property B

BRACKE

string

Brackets code

BRAD

real

Bend radius

BRALNK

element(20)

Connectivity SCBRAN-BRANCH Link

BRCOG

pos

Branch centre of gravity

BRCONNECT

element(5000)

Branch member connections

BREARE

real

Branch external surface area

BREF

element

Branch Reference

BRIARE

real

Branch internal surface area

BRICOG

pos

Branch insulated centre of gravity

BRIWEI

real

Branch insulated weight

BRLEG

element(5000)

Branch members on the same leg

BRLO

integer

Branch Positioning Status code (Router)

BRNFAC

real

Burning factor

BRNLEN

real

Length of burning contours

BRNNAM

string(26)

Burner name

BRNNUM

integer

Burner number

BRNPRC

string(26)

Burner process name

BRNREF

string(26)

Burner reference id

BRNSEQ

string(26)

Burning sequence number

BRNST

integer

Number of starts for burning

BRNTOO

integer

Burner tool

BRNTYP

string(26)

Burner type

BRREF

element

Branch table reference

BRTXRF

element(500)

Return reference from Branch Table element to SPECs

BRWCOG

pos

Branch wet centre of gravity

BRWEIG

real

Branch weight

BRWICOG

pos

Branch wet insulated centre of gravity

BRWIWEI

real

Branch insulated wet weight

BRWWEI

real

Branch wet weight

BSCANG

real

Bend Segment Cut Angle

BSCLL

real

Centre-Line Length of a miterd Bend Segment

BSDWG

string(120)

AutoCAD backing sheet name

BSEL

string(3)

Bolt Selector

BSFN

string(1024)

Backing sheet filename

BSLAYE

string(120)

AutoCAD backing sheet layer

BSMNIL

real

Minimum Length of Insulation of a miterd Bend Segment

BSMNL

real

Minimum Length of a miterd Bend Segment

BSMXIL

real

Maximum Length of Insulation of a miterd Bend Segment

BSMXL

real

Maximum Length of a miterd Bend Segment

BSPE

element

Bolt specification

BSRF

element

Backing sheet reference

BSRFA

element(500)

ADP backing sheet list

BSTA

integer

Branch Status code (Router)

BTEX

string(1000)

Annotation text string

BTHK

string(1000)

parameterized bolt thickness

BTLS

word(50)

Boundary Former type list

BTOL

string(1000)

Bore tolerance

BTOTAL

integer

Bolt joint total

BTYP

string(1000)

Bolt type

BUFS

integer

Preferred buffer size

BUIL

logical

Built/Unbuilt flag

BULG

real

Bulge factor

BUNI

word

Bore units

BUNREF

element

Cable bundle reference

BURF

element

Reference to real Building Element

BURNID

string(80)

Burner id

BUYMARK

string(26)

Buying mark

BVCODN

integer

Bevelled Code number

BVIS

logical

Bottom visibility flag

BVSCLL

real

Centre-Line Length of a miterd Bend Segment

BVSEGN

integer

Bevelled segment number

BVSMNI

real

Minimum Length of Insulation of a Virtual miterd Bend end-Segment

BVSMNL

real

Minimum Length of a virtual miterd Bend end-Segment

BVSMXI

real

Maximum Length of Insulation of a Virtual miterd Bend end-Segment

BVSMXL

real

Maximum Length of a virtual miterd Bend end-Segment

BWITHF

logical

Bend with flow

CABBOX

real(6)

Calculated box volume in world coordinates

CABGAP

real

cable gap on cabletray as multiple of OUTD

CABINT

string(120)

cable interference class

CAGOFF

real

Cage Offset

CAGSIZ

real

Cage Size

CARD

integer(2)

Cardinality definition

CARE

string(12)

Isodraft Compipe: Area

CASR

element

Case reference

CATMOD

integer

Catalogue Geometry Modified- Not directly query able

CATR

element

Catalogue reference

CATTEX

string(725)

Concatenation of Detailing and Material Texts

CATY

integer

Card type

CBACXR

real

Accumulated cables xarea at route node

CBCOG

pos

Cable centre of gravity

CBCULE

real

Cut Length of cable

CBGELE

real

Geometric Length of cable

CBNUCW

element(500)

Cables at a point on a cableway

CBPREF

element(500)

References to POINTR forming route of a cable

CBRNLS

element(500)

List of route nodes that cable passes

CBRWGL

real

Raw Geometric Length of cable

CBSTA

integer

Cable routing status

CBTOLE

real

Total Length of Cable

CBWEIG

real

Cable weight

CCEN

integer

Cost centre

CCLA

integer

Cost class

CCOL

integer

Colour (in catalogue)

CCON

word

Connection type

CCORRE

element

Cable Core set reference

CCORXR

element(500)

Return reference from CCORSET element to SCOMs

CDET

element

Catalogue detail

CDPL

word(100)

List of valid current design properties

CDPR

real

word

Current design dataset property

CDRG

string(24)

Isodraft Compipe: Drawing number

CELLID

integer(2)

Cell Identifier

CELLTO

real

Total Number of Cell

CELLTR

real

Total Number of Trimmed Cells

CELLWH

real

Total Number of Untrimmed Cells

CELREF

element

Status Element reference

CEND

string

Connection at other end of CREF (HEAD or TAIL)

CERF

element(500)

Array of Faces generated by this

CEXES

real(4)

Cable excesses

CEXS

real

Percentage excess for passing cables

CFDP

element

word

Current design dataset property

CFFA

element(500)

Array of Faces generated by this

CFILL

real

Fill level at route node

CFRA

element(10)

Cofitting reference array for Pfittings

CFRELE

real

Free Length of cable

CHALEN

real

Length of chamfer intervals

CHAM

real(2)

Chamfer lengths

CHANUM

integer

Number of chamfer intervals

CHAR

integer

Character set

CHARGE

string(80)

Charge

CHCOLO

integer

Crosshairs colour

CHCONU

integer

Crosshairs colour number

CHDCOLUMN

element

Child column

CHECKE

string(1000)

Checker

CHEI

real

Character height

CHKDAT

string(120)

Date checked

CHNGD

integer

Changed counter

CHOS

real

Crosshairs overshoot

CHPN

integer

Crosshairs pen

CHSTREF

element

Crosshairs linestyle Reference

CHSTYL

integer

Crosshairs linestyle

CIRCR

real(4)

Circumscribed rectangle

CIWE

string(1000)

Total insulation weight

CKEY

word

ISODRAFT end condition key

CLAI

integer

Claim mode

CLAIMDB

string(10)

Implicit or explicit claims

CLBASE

real

Column base offset

CLCCNT

integer

Claim list changes count

CLCOLO

integer

Centreline colour

CLCONN

element(5000)

integer

Clasher connections

CLCONU

integer

Centreline colour number

CLFG

logical

Centreline flag

CLFL

logical

Centreline flag

CLIPCD

integer

Clip code

CLIST

element(500)

All cables attached to route node

CLLE

real

Branch centreline length

CLMID

string(120)

Unique system ID of user claiming element

CLMNUM

integer

User or extract number claiming element. Extract numbers are negative

CLMO

string

Centreline mode: 1=CL OFF, 2=CL ON

CLMTIE

element(4)

Reference to elements that are automatically claimed along with this element

CLNCOD

string(120)

Ceiling Code

CLNELE

real

Ceiling Elevation

CLNFAC

real

Cleaning factor

CLNHEI

real

Ceiling Height

CLNTYP

string(120)

Ceiling Type

CLNVOI

real

Ceiling Void Height

CLOSED

logical

True if plate covering entire referenced component

CLOSEFLAG

logical

True if branch is closed

CLPN

integer

Centreline pen

CLRF

element

Actual circulation list reference

CLRSIZ

real(2)

Clearance size

CLSTREF

element

Centreline linestyle Reference

CLSTYL

integer

Centreline linestyle

CMALL

real

Structure allowance

CMAXF

real

Calculate maximum fill level on cway

CMBOUA

element

Aft boundary

CMBOUF

element

Fwd boundary

CMBOUL

element

Lower boundary

CMBOUP

element

Ps boundary

CMBOUS

element

Stbd boundary

CMBOUU

element

Upper boundary

CMBOX

real(6)

Bounding box

CMCAT

string(256)

Compartment category

CMCDE

real

Content density

CMCTID

string(256)

Content type ID

CMDESC

string(256)

Compartment description

CMFLW

real

Full Load Weight

CMINF

real

Calculate minimum fill level on cway

CMLCV

real

Longitudinal centre of total volume

CMMGE

integer

Merged compartment indicator

CMPER

real

Compartment permeability

CMPERD

real

Permeability for use in damage

CMPLNK

element

Return reference from schematic or design element to CYMLNK element

CMPR

element

Component reference

CMPRFA

element(500)

All components for the PipePiece

CMPSTATUS

word

Connectivity comparison status

CMPSTS

string(120)

Connectivity comparison status description

CMPURP

string(256)

Purpose

CMTCV

real

Transverse centre of total volume

CMTYP

integer

Type of compartment

CMVCV

real

Vertical centre of total volume

CMVOL

real

Total volume

CNTNUM

integer

Contour number

CNUM

string(22)

Isodraft Compipe: Line number

COCDRE

element(500)

word

COCDESS with same COCONN value as qualifier

COCONN

word

COCO Connection type

COCORE

element(2)

COCO description reference

COCOXR

element(500)

COCO description return reference

COCSAM

element(500)

COCOS with same CTYP value as COCDES

COLCOL

integer

Column colour

COLCON

integer

Column colour number

COLNUM

integer

Pin column number

COLSCH

string(120)

Color Schema

COLSTREF

element

Column linestyle Reference

COLSTY

integer

Column linestyle

COLXSP

real(100)

Spacing between columns in the X direction of the tower

COLYSP

real(100)

Spacing between columns in the Y direction of the tower

COMBOO

word

Boolean Combination

COMM

string(120)

Comment

COMMST

string(500)

Comment string

COMNT

string

Comment

COMPEN

logical

Compensate bending activities for springback

COMPTYPE

word

Type of component

CONAM

string

Cutout name

CONARR

word(10)

Connection array

CONATS

element(500)

List of attachment connected to attachment

CONBRA

element(500)

List of branches connected to branch

CONCD

integer

Connection code

COND

integer(500)

Access Control Logical condition

CONDES

string

Connection string

CONDGR

integer

No of Conductor Groups

CONNE

logical

Segment end connection flag

CONNECTIONS

element(5000)

Connections

CONNECTIONSH

element(5000)

Connections for all descendants

CONNER

string(300)

integer

Connection error message

CONNRE

element(10)

References to other element

CONNS

logical

Segment start connection flag

CONSIS

logical

Position consistency

CONTYP

string

Connection type

COPI

integer

Number of copies

COPYDB

element(8191)

Copies of this database

CORA

string(1000)

Corrosion thickness

CORCGR

string(120)

integer

cable core conductor group

CORNUM

integer

Corner number

CORNUV

pos

Corner point

CORROS

real

Tube corrosion

CORRUG

logical

True if corrugation is defined on the plate part

CORTAG

string(120)

integer

cable core tag

COUN

integer

Counter

CPAR

real(100)

Catalogue parameters

CPEN

integer

Pen for internal columns

CPFA

element(500)

Array of Ports this points to

CPLO

string(120)

Plot (in catalogue)

CPOF

real(2)

Leaderline connection point wrt. text origin

CPOS

pos

conditioning position for curve geometry

CPRO

real

Spot value of property C

CPUL

real(3)

Cold pull - translational

CPUT

real(3)

Cold pull - twist

CRCANG

real

Turning angle for least circumscribed rectangle

CRCLW

real(2)

Length and width of circumscribed rectangle

CRDATE

string(120)

attr

Date element created in current DB or if extract in ascendant

CREANCESTORS

logical

Create ancestors

CREF

element

Connection reference

CREXTR

integer

attr

Extract element created in current DB or if extract in ascendant

CRFA

element(10)

Connection reference array

CRINFO

string(200)

DB creation information

CRIT

integer(250)

Selection criteria (used to define tag & rep. rules)

CRSESS

integer

attr

Session element created in current DB or if extract in ascendant

CRSF

element

Change ruleset reference

CRUSER

string(120)

attr

User created element in current DB or if extract in ascendant

CSESS

string(120)

integer

Comment entered for specified session

CSFBR

logical

Spooling marker for components

CSGBOX

real(6)

CSG-Calculated box volume in world coordinates

CSPA

real

Character spacing factor

CSPC

string(6)

Isodraft Compipe: Specification

CSTA

string(120)

Catalogue Standard

CSTR

element

Constraint reference

CTCREF

element

integer

Cable tray component ref

CTHICK

real

Coating thickness

CTSPE

element

Cable tray specification

CTTYP

word

Cable tray typ

CTXT

string(120)

Card text

CTYA

word

Attached connection type

CTYE

word

End connection type

CTYO

word

Owning connection type

CTYP

word(2)

Connection type

CTYPLI

word(500)

List of COCO Ctypes

CTYS

word

Start connection type

CURD

element(1000)

Current DBs

CURF

string

Curve fitting code: 1 default, 2 cubicfit

CURLOC

element

True current location

CURREN

string(1000)

Current

CURTYP

word

Curve type

CURVED

logical

True if curved plate part.

CUTB

real

Cutback

CUTL

real

Cut length

CUTNAM

string(700)

integer

Full name of element, truncated to n characters

CUTNMN

string(700)

integer

Full name of element (without leading slash) truncated to n characters

CUTP

dir

Cutting plane normal

CWEI

string(1000)

Total component weight

CWHEAD

element(500)

Cableway Head

CWHPOS

pos

Cableway path head point position

CWIDTH

real

Clearance Width

CWJUSL

word

Cable Way Justification Line

CWLIST

element(500)

All cableways attached to route node

CWTAIL

element(500)

Cableway Tail

CWTPOS

pos

Cableway path tail point position

D

real

Position downing

DACC

string

Database access

DACCLA

logical

True if DAC allows element to be claimed

DACCOH

logical

True if DAC allows element hierarchy to be copied to another DB

DACCOP

logical

True if DAC allows element to be copied to another DB

DACCRE

logical

elemtype

True if DAC allows element to be created

DACDEL

logical

True if DAC allows element to be deleted

DACDRO

logical

True if DAC allows element to be dropped

DACERR

string(120)

attr

Returns the DAC error

DACEXH

logical

True if DAC allows element hierarchy to be exported

DACEXP

logical

True if DAC allows element to be exported

DACISS

logical

True if DAC allows element to be issued

DACMOD

logical

attr

True if DAC allows attribute of element to be modified

DACOUH

logical

True if DAC allows element hierarchy to be output

DACOUT

logical

True if DAC allows element to be output

DAREF

element

Reference of associated dataset area

DARREF

element

Design area reference

DASSCI

element(500)

Reference Array of all direct associates with constraints

DASSOS

element(500)

Reference Array of all associations with constraints

DATE

string(12)

Date

DATEFO

string

Date format

DATIM

string(19)

LMI Date/time

DATINT

integer(2)

Date

DATONE

integer

Date 1

DATTWO

integer

Date 2

DATTXT

string(22)

Date

DBAC

string

DB Access, MULTIWRITE or UPDATE

DBALL

element(8000)

List of DBs allocated to location

DBCL

string

DB Claim

DBCNTL

logical

True if element is in a control DB

DBEXNO

integer

DB Extract Number

DBF

element

Database reference attribute

DBFI

string

DB filename

DBFN

integer

DB file number

DBLC

element(1000)

List of LOCs belonging to a DB

DBLS

element(1000)

List of DBs belonging to MDB

DBNA

string

DB name

DBNU

integer

DB Number

DBOT

real

Bottom diameter

DBPR

element(8000)

List of DBs Primary at location

DBRBEG

integer

DB range start

DBREF

element

DB reference

DBREND

integer

DB range end

DBSESS

integer

Last DB session

DBSHIE

element(5000)

Database hierarchy within a DBSET

DBSLEV

element(5000)

Databases at a level within a DBSET

DBSLIS

element(5000)

Databases within a DBSET

DBSSTP

element(8000)

DBs in a stamp

DBSTF

element

Database set reference attribute

DBTE

string

DB Text Encoding

DBTY

word

DB type (DESI, CATA etc)

DBUsers

element(10000)

Current Users in the system using this DB

DBUSRX

element(10000)

Current Users in the system using this DB or any extract descendants

DBVAR

logical

True if element is in a variant DB

DBVWSTREF

element(50)

Database View Set reference array

DBWRITE

logical

True if element is in a writable DB

DCLA

string

Database claim mode

DCLNCO

string(120)

Default Ceiling Code

DCLNHE

real

Default Ceiling Height

DCLNTY

string(120)

Default Ceiling Type

DCODE

string

Direction code

DCON

word

Design PPoint connection type

DCORRO

real

Derived corrosion

DCRFA

element(10)

Array of Design datasets for Design Code/Criteria

DCSTYF

element

Design change style reference

DCTILT

real

Default Ceiling Tile Thickness

DDDF

string(1000)

Default Design data value

DDEF

real(3)

Port distance flexibility defaults

DDEG

real

Dimension line angle

DDEP

integer

Database depth within hierarchy (World is 0)

DDESP

real(100)

Design parameters as distance

DDIR

dir

Design PPoint spherical direction

DDNM

element

Design element reference

DDNMX

real

DDNM X position

DDNMXY

real(2)

DDNM XY position

DDNMY

real

DDNM Y position

DDNX

string(120)

Design element as text

DDOORS

real

Default Door Sill

DDPR

string(1000)

Design data property value

DDRFA

element(10)

Array of default design datasets (for template)

DEALAL

logical

True if location locked due to deallocation of dbs

DEALDB

element(1000)

Reference array for locations where DB id being deallocated

DECGAP

real

Decoration Gap

DECMOD

integer

Decoration Mode

DECOFF

real(2)

Decoration offset

DECP

integer

Decimal places

DECREP

real

Decoration Repeat

DECSIZ

real

Decoration Size

DEFA

real

Default

DEFATT

word(2000)

Default List of all attributes for element

DEFERD

element(10000)

Deferred DBs in MDB

DEFHOM

element

Default allocation home

DEFSLO

real

Default pipe slope

DEFSPK

element

Default Reference of SPEC for branch members

DELANG

real

Angle applied to repeat elements

DELDSG

word

Delivery Designation flag

DELP

pos

D-position in structure

DELPE

real

Easting of D-Position in STRUC

DELPN

real

Northing of D-position in STRUC

DELPU

real

Upping of D-position in STRUC

DELTAE

real

Easterly Offset applied to repeat elements

DELTAN

real

Northerly Offset applied to repeat elements

DELTAU

real

Vertical Offset applied to repeat elements

DEMIX

integer

Index of Demote Status Value

DENS

real

Spot value of density

DEPATT

word(2000)

Attributes that a rule or catalogue parameterized expression is dependent upon

DEPD

string(250)

word

Default value of local design property

DEPL

word(100)

List of local design properties

DEPR

string(250)

word

Local design property value

DEPREF

element(500)

List of elements connected to branch tail

DESC

string(120)

Description of the element

DESGEO

element(5000)

Design geometrical dependencies

DESLNK

element(20)

Connectivity Design Model Link

DESMOD

integer

Design Mode

DESP

real(100)

Design parameters

DESREF

element(10)

Design reference

DEST

string(26)

Destination

DESXCL

logical

Design Outfitting excluded Geometry

DETA

logical

Detail flag

DETR

element

Detailing text reference

DFBRADIUS

real

element

Default bend radius

DFFL

real(6)

Displacement force flexibility

DFHOME

element

element, elemtype

Get default home element

DFLA

string

Radial dimension type flag

DFLF

real(3)

Translational spring values

DFLRCO

string(120)

Default Floor Code

DFLRHE

real

Default Floor Height

DFLRTY

string(120)

Default Floor Type

DFLT

string(120)

Default value for the attribute

DFLTA

string(1000)

Defaults for Type 1 annotation - special attribute for use by ADP

DFLTB

string(1000)

Defaults for Type 2 annotation - special attribute for use by ADP

DFLTC

string(1000)

Defaults for Type 3 annotation - special attribute for use by ADP

DFNM

string(1024)

Document filename

DFON

integer

Dimension text font

DFONTN

string(80)

Dimension text font name

DFUN

element

Default unit

DHTEST

integer(500)

Test locator expression

DHTEXT

integer(500)

Default home identifier expression

DIAM

real

Diameter

DIAREF

element(500)

Diagram reference array for schematic elements

DIME

logical

DRAFT user defined symbol dimension flag

DIMPOS

pos

Derived 3D dimension position

DIMTXT

string(40)

Dimensions text

DINTER

string(257)

Default Interference class

DINTHK

real

Default insulation thickness

DIR

dir

Direction

DIREV

dir

Direction evaluation

DIRXP

integer(500)

Direction expression

DISP

real(3)

Translation displacements

DIST

real(2)

Distances

DISTAG

string(120)

Display tag

DISTFH

real

Distance from head

DISTFN

real

Distance from next point

DISTFP

real

Distance from previous point

DISTM

real(2)

Distances to M1 and M2 curves

DKEY

word

Data Key

DLCOLO

integer

Dimension line colour

DLCONU

integer

Dimension line colour number

DLEV

integer

Drawing level

DLFG

string

Linear/Angular dimension line flag

DLIM

real(6)

Displacement limit

DLIST

word(2000)

List of all possible dist att types

DLPN

integer

Dimension line pen

DLSTREF

element

Dimension linestyle Reference

DLSTYL

integer

Dimension linestyle

DMFA

element(2)

ISODRAFT Reference Dimension attribute

DMFL

real(9)

Displacement moment flexibility

DMSP

real

Lower limit to spacing between parallel dimensions

DMTX

string(1000)

Dimension text

DMTY

word(2)

ISODRAFT Reference Dimension attribute

DNST

real

Density

DOCREF

element

Document reference

DOCXRF

element(500)

Return reference from Design element to DOCITM element

DOFF

real

Dimension line offset

DOFIL

string(73)

Drawing Object filename

DPBO

real

integer

Design point bore

DPCO

word

integer

Design point connection type

DPCOU

integer

Number of valid design points

DPDI

dir

integer

Design point direction

DPFN

string(1024)

ISODRAFT dynamic detail plotfile name

DPGR

real

integer

Design Point Gradient

DPGRID

integer

ISODRAFT dynamic detail grid reference attribute

DPLS

integer(200)

List of valid design points

DPOS

pos

Dimension line/arc position

DPPS

pos

integer

Design point position

DPREMA

real

Design pres. max

DPREMI

real

Design pres. min

DPRO

string(1000)

parameterized Property Expression (Default)

DPSF

element

Design PPointset reference

DPVI

integer(200)

List of visible design points

DRAD

string(1000)

Radial offset

DRAWNO

string(26)

Drawing number

DREVAY

element(50)

DRWG revisions array

DRFILE

string(73)

Drawing File name

DRFNUM

integer(11)

Drawing file numbers

DRFTYP

integer(11)

Drawing File Types

DRGP

integer

Drawing priority (used to determine how to draw SCTN)

DRMXTL

integer

Draft general max text length

DRNE

dir

Plane normal at end of SCTN/GENSEC

DRNS

dir

Plane normal at start of SCTN/GENSEC

DRPS

pos

Derived position for steelwork

DRRF

element

Old spooler drawing reference

DRSSRE

element

Draft Symbol set reference

DRTITL

string(120)

Drawing title

DRTMPR

element

Draft template reference

DRWGN

string(1000)

Drawing number

DSCO

string(120)

Design code

DSESS

string(120)

integer

Date of specified session

DSET

logical(3)

Displacement limits set flag - ignore values if FALSE

DSGNTN

string

Designation

DSTNCE

real

Distance

DSTY

string

Radial dimension style flag

DTAN

string

Dimension text angle flag

DTCH

real

Dimension text character height

DTCOLO

integer

Dimension text colour

DTCONU

integer

Dimension text colour number

DTER

string

Dimension terminator code

DTFL

string

Dimension text radius flag

DTIT

string(32)

Data Title

DTLELE

element(5000)

Datal Elements list

DTLH

real

Dimension text letter height

DTLLIST

word(2000)

Datal Attributes List

DTLTST

integer(8192)

Datal Test attribute

DTMPMA

real

Design temp. max

DTMPMI

real

Design temp. min

DTOF

real(2)

Dimension text offset

DTOP

real

Top diameter

DTPN

integer

Dimension text pen

DTRA

real

Dimension text radius

DTRE

element

Data set reference

DTUL

string

Dimension text underlining flag

DTWTCL

string

Date of weight/cog calculation

DTXR

string(120)

RTEXT of detailing text

DTXS

string(120)

STEXT of detailing text

DTXT

string(120)

TTEXT of detailing text

DUCTHE

real

Default duct height

DUCTSH

word

Default duct shape

DUCTWI

real

Default duct width

DUNI

word

Distance units

DUNION

integer

DRAFT element union detail flag

DUPLIC

element(10000)

integer

Duplicates of the current element with the same attribute values

DUTY

string(120)

Duty

DVFL

logical

ADP detail views flag

DVSCL

real(500)

ADP detail view allowable scale list

DVTH

real

ADP detail views threshold

DWALLT

real

Derive wall thickness

DWID

string(1000)

Width offset

DWINSI

real

Default Window Sill

DX

string(1000)

Cartesian X offset

DXL

string(1000)

Incremental X length

DY

string(1000)

Cartesian Y offset

DYL

string(1000)

Incremental Y length

E

real

Position easting

EASTING

pos

Easting part expressed as a position

ECCE

pos

Eccentricity (steelwork)

ECCJ

pos

Eccentricity of joint (steelwork)

ECLASS

word(100)

Access Control Element class

ECRFA

element(500)

Equipment connection reference array

EDGELE

real

Edge Length

EDISTA

real

Vertical Distance of End

EDPUV

pos

End point

EFAC

string(1000)

E-factor

EFOR

real(3)

End force vector components

ELCXRF

element(500)

Return reference from CABLE element to ELCONN element

ELDATA

integer(8192)

data

ELDSZ

integer

DataSize

ELECRE

logical

integer

True if created since given session

ELECREC

logical

True if created since comparison date

ELEDEL

logical

integer

True if deleted since given session

ELEDELC

logical

True if deleted since comparison date

ELEL

word(200)

Types of elements (including UDETs) to which this attribute applies

ELEMOD

logical

integer

True if modified since given session

ELEMODC

logical

True if modified since comparison date

ELEPTR

integer

Elemp

ELESZ

integer

Size

ELEVAT

real

Elevation

ELEVV

logical

Is Elevation View

ELRATI

real

Electrical Rating

ELTYPC

word

Element type

ELVRSN

integer

Element version

EMOM

real(3)

End moment components

ENCODB

string

DB Encoding

ENDA

real

End angle

ENDELE

real

End Elevation

ENDOFF

real

Offset of the end of section

ENDPOINT

integer

Cable End connection point

ENDPOS

pos

End Position

ENDREF

element

Cable End reference

EPARAM

real(6)

Evaluated parameters

EPKDI

real

Proportional distance of end point along Pline

EPOSTO

real

End post tangent offset

EREC

integer

Erection class

EREL

integer

End releases (packed)

ETEX

string(1000)

Example text

EVOL

real(6)

Enclosing box volume in given coordinates

EXBTEX

string(1500)

Expanded annotation text

EXCESS

real

Excess

EXCLEN

real(3)

Length of excess intervals (type 1-3)

EXCLFR

logical

True if element claimed from this extract. Only True for Primary elements

EXCLFT

real

Excess on left side of seam

EXCLHI

element(5000)

Primary elements in descendant hierarchy claimed to this extract (includes this element)

EXCLPA

logical

True if element claimed to Parent extract. Only True for Primary elements

EXCLTO

logical

True if element claimed to this extract. Only True for Primary elements

EXCNUM

int(3)

Number of excess intervals (type 1-3)

EXCRGT

real

Excess on right side of seam

EXCTLF

integer

Excess type on left side of seam

EXCTRG

integer

Excess type on right side of seam

EXDMTX

string(1500)

Expanded dimension text

EXECAFTER

string(512)

Exec file after DB propagation

EXECBEFORE

string(512)

Exec file before DB propagation

EXFI

integer

Extract file number

EXHCNC

element(5000)

As EXTCNC, but repeat test for all descendants

EXHCNN

element(5000)

As EXTCNN, but repeat test for all descendants

EXHCON

element(5000)

As EXTCON, but repeat test for all descendants

EXHRCN

element(5000)

As EXRCN, but repeat test for all descendants

EXHRCO

element(5000)

As EXTRCO, but repeat test for all descendants

EXMOC

logical

As EXMOD but ignoring changes to "noclaim" attributes and member lists

EXMOD

logical

True if element modified in this extract

EXNCLH

element(5000)

Primary elements in descendant hierarchy not claimed to this extract

EXPA

real

Spot value of expansion coefficient

EXPIRY

string(50)

Protected DB Expiry date

EXPLTX

string(1500)

Expanded projection line text

EXPMOC

logical

As EXPMOD but ignoring changes to "noclaim" attributes and member lists

EXPMOD

logical

True if primary and element or non-primary descendants have been modified in this extract

EXPRESSION

string(4000)

Expression

EXPTYPE

string(60)

Expression type

EXTALS

element(8191)

Extract ancestors

EXTBOX

real(6)

Defined box

EXTCLS

element(8191)

Extract children

EXTCNC

element(5000)

As EXTCON but excluding non modified elements

EXTCNN

element(5000)

As EXTCON but excluding modified elements

EXTCON

element(5000)

Primary elements connected/disconnected from element or non primary descendants in extract

EXTDES

element(8191)

Extract descendants

EXTDIR

string(10)

Direction of ladder exit

EXTFAM

element(8191)

Extract family

EXTHI

integer

Location extract number range, high limit

EXTLO

integer

Location extract number range, low limit

EXTMAS

element

Extract master

EXTNO

integer

Extract number

EXTNSN

real

Extension

EXTOWN

element

Extract owner

EXTRC

string(120)

Name of extract claiming element

EXTRCN

element(5000)

As EXTCNN, but applied recursively to each connection

EXTRCO

element(5000)

As EXTCON, but applied recursively to each connection

EXTREF

element

References to exit level

EZDI

real

End load point in section

FAAN

integer

Skew angle for font file

FACODE

string(100)

Facode

FAILCO

integer

FailCond

FAREA

string(5)

Construction area

FCDATE

integer(2)

File creation date

FCENTRE

pos

Centre of fillet arc

FCLXSP

real(100)

Spacing between stair flights in the X direction of the tower

FCLYSP

real(100)

Spacing between stair flights in the Y direction of the tower

FCMEAS

real

Flange correction measure

FCODE

string

Face code

FCOE

real(3)

Friction coefficient

FCOLOUR

integer

Fill colour

FCONUM

integer

Fill colour number

FCPY

element

Forward copy reference

FDEPD

string(250)

word

Formatted Local Design Property Default Value

FDEPR

string(250)

word

Formatted Local Design Property Value

FDRA

string(32)

Isometric drawing number

FEDEXS

real(500)

Feed excess values

FEMCOL

integer

FEM image object colour

FEND

pos

Fillet arc position

FEQDES

string(120)

From Equipment Description

FFCOLO

integer

Front-face colour

FFCONU

integer

Front-face colour number

FFLEXT

real

Edge Extension Around Floor layer

FFPN

integer

Front-face pen

FFSTREF

element

Front-face linestyle Reference

FFSTYL

integer

Front-face linestyle

FGAP

real

First offset distance

FGRF

element(500)

Reference to boundary faces

FILCHK

logical

FILCHK (true if fill level check is enabled )

FILEEX

logical

True if DB file exists and is valid

FILENAME

string

DB filename

FILL

logical

DRAFT user defined symbol fill flag

Fill level check

logical

Fill level check

FILLDI

word

Fill direction

FILREF

element(500)

Sorted references to attachment points with ascending order of fill level greater then 0

FILTOPERATOR

string(20)

Filter operator

FILTVALUE

string(1000)

Filter value

FINO

integer

File number

FINPUT

string(120)

Input by

FIRE

real

Fire resistance

FIRERATING

string(120)

Fire rating

FISSUE

string(12)

Current pipe spec issue

FITLEN

real

Length of branch fitting

FIXT

string(12)

Structural fixity

FLALLO

real

Flange allowance

FLATYP

integer

Flange type

FLCARE

real

Floor cover area

FLCSTHICKNESS

real

Floor cover thickness

FLCVOL

real

Floor cover volume

FLEN

string(1024)

External file name

FLEVEL

real

Fill level at route node

FLIM

real(3)

Force limit

FLLARE

real

Floor layer area

FLLTHK

real

Floor layer thickness

FLLVOL

real

Floor layer volume

FLNM

string(700)

Full name of the element

FLNN

string(700)

Full name of the element (without leading slash)

FLOFFS

real

Flange offset

FLOW

word

Flow direction

FLRCOD

string(120)

Floor Code

FLRELE

real

Floor Elevation

FLRELV

real

Floor elevation

FLRHEI

real

Floor Height

FLRTYP

string(120)

Floor Type

FLTDIR

dir

Stairflight Direction

FLUR

element

Fluid reference

FLWA

logical

DRAFT user defined symbol flow arrow

FMID

pos

Middle point of fillet arc

FNAM

string(1024)

Filename

FNCCD

integer

Functional description code

FNCTXT

string(80)

Functional description

FNMA

string(32)

Standard font file name

FNMB

string(32)

Bold font file name

FNTD

string(32)

Font directory

FOLDED

logical

True if folded

FONT

integer

Text font

FONTN

string(80)

Font name

FOOTRO

real

Clear space behind each rung

FORC

real(3)

Force vector

FOREIGN

string

DB foreign/local

FPATH

string(256)

File path

FPEN

integer

Fill pen

FPLINE

string(32)

Process line number

FPON

integer

FROM port number

FPRDE

string(250)

word

Formatted property default

FPROP

string(250)

word

Formatted property value from dataset

FRAD

real

Fillet radius

FRDR

string(32)

Reference drawings

FREF

element

Fitting reference

FREV

string(4)

Isometric drawing revision

FRMSCL

real

Form scale

FRPO

pos

Eye point

FRSTW

element

word

Reference of first world of given DB type in current MDB

FSPOST

real

Distance to the first post

FSTART

pos

Fillet start position

FSTAT

string(15)

Fstatus

FSTNUM

integer

Fill style number

FSTREF

element

Fill style Reference

FSTYLE

integer

Fill style

FSTYNO

integer

Fill Style Number

FTCDD

string(250)

word

Formatted Current Design Property Default Value

FTCDP

string(250)

word

Formatted Current Design Property Value

FTER

string

First dimension terminator code

FTHICKNESS

real

Stair Flight Thickness

FULLEN

real

Total length of manufactured profile

FULLT

string

type of the element

FULSYS

string

Type of the element, ignoring UDET, not truncated

FUNC

string(120)

Function

FUNI

integer

FUNIT

FURNRF

element

Furniture Reference

GANGLE

real

General Angle

GAPALL

string(1000)

Gap Allowance

GAPF

real

First offset distance

GAPI

real

Intermediate offset distance

GAPS

real(30)

Projection line gap array

GAREA

real

Ceiling Grid Area

GASTIG

logical

Gas Tight

GATECO

string(120)

Gate Configuration

GATESI

real(2)

Gate Size

GBOX

real

Box gap

GCOF

pos

Gross centre of gravity

GDEFIN

integer(100)

Glyph Outline Definition

GDIAM

integer

Glyph Circle Diameter

GENGT

word

Geometry type

GENSTR

string

General strings

GENTYP

word

Type of geometry

GEODEP

element(5000)

Direct geometrical dependencies

GEOM

integer

Geometry Modified- Not directly queryable

GFILLD

logical

Glyph Primitive Filled Flag

GHEIGH

real

Gate Height

GLBSTR

logical

True if Project has Global structure

GLBVER

string(120)

Global version string

GLYNO

integer

Glyph Number

GLYNUM

integer

Glyph Number

GLYREF

element

Glyph Reference

GMOF

real(9)

Gross moments of inertia

GMRE

element

Geometry set reference

GOBREF

element

Generating reference

GOFFS

integer(2)

Glyph Primitive offset

GOING

real(10)

Tread Going

GPPRXS

element(500)

Group proxy items referring to element

GPSTR

string

General purpose strings

GRADE

real

Steel grade

GRAXE

integer

Grid axes (internal)

GRDAXE

string

Grid axes

GRDDIR

dir

Grid direction

GRDE

real

Gradient of implied tube. Gradient is the vertical rise(fall) divided by the horizontal distance.

GRDID

string(20)

Grid Identifier

GRDLBL

string(20)

Grid Label

GRDLID

integer(2)

Gridline Identifier

GRDLXP

real

Proportion along X gridline from Gridline ID

GRDLYP

real

Proportion along Y gridline from Gridline ID

GRDOFF

real

Grid offset

GRDPOS

pos

Grid Position

GRDXSP

real(10000)

Grid X Spacing

GRDYSP

real(10000)

Grid Y Spacing

GRIDNM

element

Design grid reference

GRIDNX

string(120)

Design element as text

GRIND

real

Grinding info

GRILEN

real

Length of grinding intervals

GRINUM

integer

Number of grinding intervals

GRIP

real

Minimum distance between bends

GROUPS

element(500)

GPSETs in which element occurs

GRPRF

element

Reference to group (owner of location)

GRSYS

element

Grid system reference

GSRF

real

Gross surface area

GSTR

element

Structural geometry set reference

GTAREAS

element(5000)

All areas that fully or partially enclose element

GTEXAREAS

element(5000)

All areas that fully enclose element

GTXT

string(120)

Text storing rule to generate Inventory List

GTYP

word

Generic type

GVOL

real

Gross volume

GWEI

real

Gross weight

GWIDTH

real

Gate Width

GXLEN

integer

Glyph Rectangle XLength

GXYOFF

real(2)

Grid XY Offset

GYLEN

integer

Glyph Rectangle YLength

HANGLE

real

Hatching Angle

HAZARD

string(120)

Hazard

HAZTYP

string(120)

Hazard Description

HBLBOX

real(6)

Block box

HBOR

real

Head bore

HCCNT

integer

Header/Extract list changes count

HCOFG

pos

computed hull item centre of gravity

HCON

word

Head connection type

HCORRO

real

Head Corrosion

HCREF

element(10)

Head connections

HDBREF

element

Generic Hull DB Ref

HDCONN

element(500)

List of elements connected to branch head

HDIR

dir

Head direction

HDMF

element(2)

ISODRAFT Reference Dimension attribute

HDMT

word(2)

ISODRAFT Reference Dimension attribute

HDREF

element(500)

List of attachment connected to attachment

HDUPLI

element(10000)

integer

Duplicates of the current element (checking members)

HEADCL

real

Head Clearance

HEADRO

real

Headroom

HEATT

integer

Heat Treatment

HEIARR

real(10)

Height array

HEID

real

Default Height value

HEIF

real

Height attractor factor

HEIG

real

Height

HEIL

real(2)

Height limits (Min/Max)

HEIS

logical

Height set flag - ignore Height values if FALSE

HEND

string

Connection at other end of HREF (HEAD or TAIL)

HGHT

real

Height

HGSIDE

word

Hinge side

HHBO

real

Hanger head bore

HHBP

pos

Bottom of hanger head

HHCO

word

Hanger head connection type

HHDR

dir

Hanger head direction

HHGR

real

Hanger head gradient

HHOD

real

Hanger head outside diameter

HHPO

pos

Hanger head position

HHTP

pos

Top of hanger head

HIERARCHY

element(5000)

Structural connections

HIST

integer(120)

attr

History of sessions in which element or specified attribute were made

HLCOLO

string

Hull Colour

HLIS

word(2000)

List of all possible types in owning hierarchy

HLSTREF

element

Hatching linestyle Reference

HLSTYLE

integer

Hatching linestyle

HMAV

real

Average humidity

HMMA

real

Maximum humidity

HMMI

real

Minimum humidity

HNCKEY

integer

Hole Notch Cutout Key

HOFFSE

real

Hatching Line Offset

HOFFT

real

Head offset

HOLGRD

logical

True if any hole in the plate should be ground

HPATNO

integer

Hatch Pattern Number

HPOS

pos

Head position

HPOSE

real

Easting of head position

HPOSN

real

Northing of head position

HPOSU

real

Upping of head position

HPREF

element

Head point reference

HREF

element

Head reference

HREL

logical

Branch Member Head relative flag (Router)

HRJUSL

word

Handrail Justification Line

HRSF

element

Hatch ruleset reference

HSARFA

element(500)

HVACSpool arrive references

HSEPAR

real

Hatching Line Separation

HSLRFA

element(500)

HVACSpool leave references

HSPE

element

Hanger specification

HSRFA

real

Computed Hull item surface area

HSRO

element

Headrod specification

HSTU

element

Head tube specification

HSTYF

element

Hatch style reference

HTBO

real

Hanger tail bore

HTBP

pos

Bottom of hanger tail

HTCO

word

Hanger tail connection type

HTDR

dir

Hanger tail direction

HTGR

real

Hanger tail gradient

HTOD

real

Hanger tail outside diameter

HTPO

pos

Hanger tail position

HTPREF

element

Topology reference

HTTP

pos

Top of hanger tail

HTYP

word

Hanger type

HUBRF

element

Reference to the hub location

HULAPP

logical

Hull applicable Geometry

HULCNT

integer

Size of hull array/collection

HULLDE

logical

True if element is a hull design item

HULLOB

element

Hull object reference

HULLPR

logical

True if element is a hull production item

HULOC

string

Location

HUMIDI

real

Design Humidity

HUMIRR

logical

True if mirrored in local v-axis

HUMVW

string

Model View

HUREFL

logical

Reflected

HUREPL

element

Replica

HUSYMM

logical

Symmetrical

HVOLU

real

Computed Hull Item volume

HWALLT

real

Head wall thickness

HWEIG

real

computed analytic hull item weight

HWRF

element

Head Working Point (Router)

IBLNAM

string

Name of idealised block

ICAT

element

Insulation catalogue reference

ICLASS

string(120)

Interference class

ICON

string(120)

ICON

ICONL

string(120)

ICONL

ICONN

integer

COMMS connection type (0/1 = on/off-line)

ICONS

string(120)

ICONS

ICOTYP

string(300)

Icon used for element

IDENT

string

Panel identification string

IDET

element

Insulation detail text reference

IDLABL

real

Length of label idle movement

IDLFAC

real

Idle movement factor

IDLL

real(3)

Burning idle length

IDLLEN

real(2)

Non-burning idle length

IDLN

element

Drawlist name reference

IDLX

string(120)

Drawlist name (as text)

IDNM

element

Design data or catalogue component

IDNX

string(120)

Design data or catalogue component (as text)

IDRT

string(2000)

Insulation detail RTEXT

IDSPU

integer

Specified unique identifier

IDST

string(2000)

Insulation detail STEXT

IDTT

string(2000)

Insulation detail TTEXT

IGAP

real

Intermediate offset distance

IGNDUN

logical

Ignore DUnion flag

IMAT

element

Insulation material text reference

IMGDAT

integer(8192)

Image data

IMPED

string(1000)

Impedance

IMXT

string(2000)

Insulation material XTEXT

IMYT

string(2000)

Insulation material YTEXT

IMZT

string(2000)

Insulation material ZTEXT

INCBOR

real

Inch Nominal Bore

INCL

real

Inclination angle

INFA

string(119)

Client info - Project Name

INFB

string(119)

Comment - Project Message

INFG

logical

Insulation flag

INFOTE

string(120)

Infotext

INIVAL

element

Initial Value

INMTRF

element

INSMAT Reference

INPINDEN

real

Insulation pin density (Area)

INPINLEN

real

Pin length

INPINT

string(120)

Insulation pin type

INPRTR

element

Inside paint reference

INRE

element

Insulation reference

INRF

element

Array of Inventory Items

INSARE

real

Insulation requirement area

INSC

string(120)

Inspection schedule

INSL

logical

DRAFT user defined symbol insulation flag

INSTNC

string

Bracket instance name

INSTOPTIONS

string(120)

Installation Options

INSURE

element

Reference to a INSCMP element

INSUTY

string(120)

Insulation type

INSYST

element(500)

Reference Array of all SYSGRPs Elements

INTHK

real

Insulation thickness

INTSEN

logical

Installation Sense - true if clockwise

INTY

word

Inventory item type

INVF

element(500)

Array of Inventory Items

INVI

logical(500)

Visibility state

IPAR

real(30)

Parameters of the insulation catalogue component

IPRE

real

Internal pressure

IRNO

string

ISO-IR number

ISCOPY

logical

True if a copy DB

ISDBFR

logical

True if database is foreign

ISDBPR

logical

True if database is primary for global working

ISDRDB

logical

True if database has drawings

ISECPT

pos

Intersection point

ISEXAP

logical

True if extract ancestry is primary here

ISEXCP

logical

True if all extract children are primary here

ISEXMP

logical

True if extract master is primary here

ISEXOP

logical

True if extract owner is primary here

ISEXTR

logical

True if an extract

ISFOR

logical

True if database is foreign

ISKEYDB

logical

Does ukey incorporate DB number

ISLOADED

logical

True if Sheet is loaded

ISMAST

logical

True if a Master DB, that is top level extract

ISNAMED

logical

True if element is named

ISOHIDDEN

logical

Isohidden flag

ISPE

element

Insulation spec reference

ISPICF

logical

Picture has File

ISPR

element

Insulation specification component reference

ISPRIM

logical

True if database is primary at this location

ISSUE

logical

True if drawing has been issued

ISWORK

logical

True if a working extract

ITLE

real

Length of implied tube

ITMTBL

integer(2000)

Table linking AITEMS elements to piping components

ITPS

pos

Position of implied tube

IWDORF

element(1500)

Weld owners attribute on IWELD elements

IWDOWN

integer(8)

Table linking IWELD elements to piping components

JFRE

logical

True if Section position dominates a connection

JLIN

word

Joining line

JLNE

word

Joining line end

JLNS

word

Joining line start

JMAX

integer

Maximum joint number in current spool drawing

JNTBEV

real(2)

Joint part bevel code

JNTC

integer

Joint Code

JNTCOM

string(300)

Welded joint comment

JNTNAM

string(26)

Welded joint name

JNTNUMBER

integer

Joint number

JNTORF

element(1500)

Joint owners attribute on IJOINT elements

JNTOWN

integer(8)

Table linking IJOINT elements to piping components

JNTREF

element

integer

Return reference from Ppoint to ijoint element

JNTTHK

real(2)

Joint part thickness

JNTTSL

real

Total welded joint suspension length

JNTTWL

real

Total welded joint length

JNTTYP

string(26)

Welded joint type

JNUM

integer(2)

Old spooler joint number

JOIE

element

End joint

JOIP

word(2)

Old spooler joint number prefix

JOIS

element

Start joint

JUSL

word

Justification Pline

JUST

string

Justification

KNUANG

real

Knuckle angle

KNUCKL

logical

True if knuckled

LABOFFS

real(3)

Label offset

LABPOS

pos

Label position

LABST

integer

Number of starts for label signing

LACR

logical

Access Control on/off switch

LACTIV

logical

True if selectable : false = limbospec

LALCAB

element(500)

List arriving leaving cables on attached point

LALLAN

real

Leave Ppoint allowed angle

LASTM

string(120)

attr

Date of last modification

LAUTHU

logical

Login Authentication on/off switch

LAXE

ori

Local axes

LAYARF

element

Annotation Layer ruleset reference

LAYDRF

element

Design Layer ruleset reference

LAYTBF

element

Layer Table reference

LBBORE

logical

TRUE if Minor/Branch bore is in nominal bore table

LBOP

pos

Bottom of leave pipe

LBOR

real

Leave bore

LCAS

integer

Load case number

LCHA

logical

Chain flag

LCIRCR

real(8)

Least circumscribed rectangle

LCKPSW

logical

Lock passwords for general users

LCLAIM

logical

Access Control Claim flag

LCLM

logical

True if element is claimed

LCLMH

logical

True if element and hierarchy claimed

LCNFA

element(500)

Array of elements with local names

LCON

word

Leave connection type

LCORRO

real

Leave corrosion allowance

LCPOVWRITE

logical

Location Overwrite DB Users policy flag

LCTROL

logical

Controlled DB Flag

LCUTDI

dir

Lower Extension Cutting Direction

LDFLT

logical

logical default value for a UDA

LDI

dir

Leave direction

LDISP

logical

Display property flag for design datasets: True if property is shown on form

LDPR

real

word

Local design dataset property

LDRDIR

dir

Ladder Direction

LEAFS

real

Number of door leafs

LEAHEI

real

Leave height

LEAV

integer

Leave Ppoint

LEAWID

real

Leave width

LEND

logical

Line end

LENDTI

integer

Time out period for commands

LENG

real

Length

LENSEG

real

Length of segment

LETTER

string(120)

Letter

LEVE

integer(2)

Drawing level

LEVENL

integer

Time interval for Event Loop

LEVRFA

element(500)

References to levels serviced by stairwell

LEXTNS

real

Lower Extension Length

LFADIR

dir

Flight A Direction

LFAOFFSET

real

Landing Flight A Offset

LFBDIR

dir

Landing Flight B Direction

LFBOFFSET

real

Landing Flight B Offset

LFCOLO

integer

Label frame colour

LFCONU

integer

Label frame colour number

LFDP

element

word

Local design dataset property

LFPN

integer

Label frame pen

LFRA

logical

Frame flag

LFSTREF

element

Label frame linestyle Reference

LFSTYL

integer

Label frame linestyle

LGAP

real

Last offset distance

LGOING

real(10)

Lower Tread Going

LGRD

real

Leave Ppoint gradient

LHBORE

logical

TRUE if Major/Header bore is in nominal bore table

LHEA

logical

Logical head flag

LHEI

real

Letter height

LHIDE

logical

Hide flag for catalogue datasets: True if property is not shown on form

LIGHTI

real

Lighting requirements

LIMI

real(6)

Volume of interest

LIMNUM

integer

Order number of limit

LINIT

logical

Location initialization flag

LINKRE

element

Link reference

LINKS

element(5000)

Linked elements

LINKSN

integer

Linked session on parent extract

LINKXR

element(1000)

Referencing elements

LISS

logical

True if drawing has been issued

LIST

word(2000)

List of all possible member types

LLCL

real

Leader line clearance

LLCOLO

integer

Label leader colour

LLCONU

integer

Label leader colour number

LLDIAGRAMS

string(2000)

Line list diagrams

LLEA

logical

Leader line flag

LLENG

real

Leave length

LLENTRY

logical

Is a line list entry - true or false

LLFROM

string(2000)

From column text for a line list

LLIS

word(2000)

List of all possible types in member hierarchy

LLPN

integer

Label leader pen

LLSTREF

element

Label leader linestyle Reference

LLSTYL

integer

Label leader linestyle

LLTBRANCH

element

Line list tail branch

LLTO

string(2000)

To column text for a line list

LMAXTR

integer

Maximum number of retries for command

LMERDL

logical

PDMS GLOBAL Enable automatic merge of transaction db

LMERFAILURE

integer

Number of days Failed commands persist in Trans dB

LMERSUCCESS

integer

Number of days Successful commands persist in Trans dB

LMERTI

string(120)

Frequency of Auto Merge of Transaction DB

LMIRR

logical

True if Mirroring required

LNAME

string(20)

Local name as stored on template

LNDLEV

real(100)

Landing levels from owning element

LNFA

element(480)

Hidden Reference Array for linked Vertices

LNKCLS

element(500)

Classes referencing a DocLink

LNKDOC

element(500)

DocLinks referring to element

LNKELE

element(500)

Elements referencing a DocLink

LNKPRP

word

TRUE if item pointed to by descriptor should be propagated by Global

LNKREF

element

Reference internal document (drawing/sheet)

LNKRX

element

Reference to first location of a link

LNKRY

element

Reference to second location of a link

LNKUSE

word

Link Descriptor Usage

LNKWV

integer

Link weighting value

LNLST

string(2000)

List of local names for current template

LNOUPDATE

logical

DB propagation suppressed flag

LNPRXS

element(500)

Proxy items referring to element

LNTP

word

Line type

LOCA

string(120)

Location

LOCID

string(3)

Location identifier

LOCK

logical

True if element is locked

LOCPR

element(1000)

List of LOCs Primary at location

LOCRF

element

Location reference

LOCTYP

integer

Location

LOD

real

Leave Ppoint outside diameter

LOFF

logical

Offline flag

LOGEV

logical

Logical value evaluation

LOGFN

string(1024)

COMMS log file name

LOGLV

integer

COMMS log file level of detail

LOGMS

logical

COMMS log file active/inactive flag

LOGXP

integer(500)

Logical expression

LOHE

real

PLOOP height - from first PLOOP in owning panel

LOOS

logical

Loose

LOWGAP

real

Lower Gap

LOWPOS

pos

Point nearest workshop floor

LOWREF

element

References to lower exit level

LPOS

pos

Leave position

LPOSE

real

Easting of leave position

LPOSN

real

Northing of leave position

LPOSU

real

Upping of leave position

LPROT

logical

Protected DB Flag

LQAANG

real

Angle between alignment direction of leave Ppoint and next

LQANG

real

Angle between leave Ppoint and next component

LQBORE

logical

TRUE if leave Ppoint has same bore as next

LQCON

logical

TRUE if leave Ppoint has Correct connection type

LQOFF

real

Offset between leave Ppoint and next component

LRBORE

logical

TRUE if bores is in reducer table

LREF

element

Link reference

LREFO

logical

Database holds Reference data only flag

LRISE

real

Lower Tread Rise

LSELEC

logical

True if can be set Directly in Design

LSHA

string

Leader shape code

LSPA

real

Text line spacing factor

LSRO

element

Leave rod specification

LSTR

logical

Stress flag

LSTU

element

Leave tube reference

LSTYNO

integer

Line Style Number

LSWID

real

Line Style Width

LSWKEY

string(120)

Line Style Width Key

LTAI

logical

Logical tail flag

LTBORE

logical

TRUE if bores is in branch (tee) table

LTCORR

real

Leave tube corrosion allowance

LTER

string

Label terminator code

LTHICK

real

Door leaf thickness

LTIMEI

integer

Time Interval between retries

LTLE

real

Length of leave implied tube

LTOP

pos

Top of leave pipe

LTWALL

real

Leave tube wall thickness

LTWREF

element

Leave tube wall thickness reference

LVAR

logical

Variant Flag

LVIS

logical

Visibility flag

LVOL

real(6)

Enclosing box volume in local coordinates

LWAITD

integer

Time interval between re-sending commands

LWALLT

real

Leave wall thickness

LWIDTH

real

Line Width

LWP

pos

Lower Working Point

LYCOL

integer

AutoCAD Layer Colour

LYCVFR

logical

AutoCAD Layer Current Viewport Freeze

LYDIR

dir

Leave Y axis direction on point

LYFRZE

logical

AutoCAD Layer Freeze flag

LYLOCK

logical

AutoCAD Layer Lock flag

LYLTYP

string(120)

AutoCAD Layer LineType

LYLWT

real

AutoCAD Layer LineWeight

LYNVFR

logical

AutoCAD Layer New Viewport Freeze

LYPFG

logical

AutoCAD Layer Plotting flag

LYPSTY

string(120)

AutoCAD Layer Plotter Style

LYVIS

logical

AutoCAD Layer Visibility Flag

LZDIR

dir

Leave alignment direction

MACRID

string

Clip macro ID

MAINTENANCE

real

Maintenance level radiation

MAKER

string(100)

Maker

MANBLK

string

Name of owner block

MANCOG

pos

Center of gravity

MANLEN

real

Length of manual intervals

MANNUM

integer

Number of manual intervals

MANPAN

string

Name of owner panel

MANTRA

real(16)

Transformation from local coordinate system

MANTYP

string(26)

Manufactured type, for example. Plane, Curved,...

MANU

string(120)

Manufacturer Name

MANWGH

real

Weight

MARKRF

element(100)

Cable Mark points

MARPTY

integer

Marine picture type

MATANG

real

Material Lay Angle

MATDEN

real

Material density

MATDIR

dir

Material direction

MATID

integer

Material ID

MATLEN

real

Material Length

MATN

string(1000)

Material Note

MATOVE

real

Material Overlap

MATPURPOSE

word

Material purpose

MATR

element

Material reference

MATWID

real

Material Width

MATX

element

Material text

MAXA

real

Maximum answer

MAXARE

real

Maximum area

MAXB

real

Maximum bore

MAXD

integer

DB hierarchy depth of lowest level item beneath element

MAXFIL

real

Maximum percentage fill level

MAXHUM

real

Maximum Humidity

MAXLP

real

Maximum length of pipe

MAXMIN

real(2)

Maximum and minimum values of design property

MAXOD

real

Maximum Outer Diameter

MAXPLN

pos

Maximum Plane Position

MAXPRE

real

Maximum Pressure

MAXREP

integer

Maximum number of Repeat items created

MAXSLO

real

Maximum pipe slope

MAXTEM

real

Maximum Temperature

MAXU

integer

Maximum number of user

MAXVOL

real

Maximum Volume

MAXWAT

real

Maximum Water Level

MBACK

element(10000)

elemtype

Members in reverse order

MBUFS

integer

Preferred buffer size in MBytes

MCBENT

logical

Machine bent

MCOLOUR

integer

Marker colour

MCONUM

integer

Marker colour number

MCOU

integer

elemtype

Number of Element Members of Given type

MDBCLS

element(1000)

List of MDBs in which DB is current

MDBLS

element(1000)

List of MDBs to which DB belongs

MDSYSF

element(10)

Reference Array of Model and Design Elements

MELRFA

element(500)

All components (non-tube) in the PipePiece

MEMB

element(10000)

elemtype

All members, or members of specific type

MEMDAB

element(10000)

Dabacon members

MEML

word

Member line for SCTNs

MEMNAM

string(120)

Member name

MEMTYP

string(256)

Member type array

MFAR

word(50)

Model Function Word array

MFFIND

element

Find Manufacturingpackage folder

MFLG

logical

Master link flag - SLAVE if FALSE

MIDP

pos

Section midpoint (steelwork)

MINARE

real

Minimum area

MINBEN

string(1000)

Minimum Bend Radius

MINFED

real(500)

Minimum feed values

MINFIL

real

Min Fill level on Cableway and Cabletray components

MINHUM

real

Minimum Humidity

MINLP

real

Minimum length of pipe

MINOD

real

Minimum Outer Diameter

MINPLN

pos

Minimum Plane Position

MINPOS

integer

Smallest position number of nested plate parts

MINPRE

real

Minimum Pressure

MINSLO

real

Minimum pipe slope

MINTEM

real

Minimum Temperature

MINVER

real

Minimum vertical pipe slope

MINVOL

real

Minimum Volume

MIRROR

logical

True if mirrored in local v-axis

MLEF

real

Minimum length excluding flange

MLIF

real

Minimum length including flange

MLIM

real(3)

Moment limits

MLNCOL

integer

Member-line colour

MLNCON

integer

Member-line colour number

MLNP

integer

Member line pen

MLNSTREF

element

Member-line linestyle Reference

MLNSTY

integer

Member-line linestyle

MMBOR

real

MM Nominal Bore

MODATT

logical

attr

True if attribute of element can be modified

MODDEL

logical

attr

True if element can be deleted

MODERR

string(120)

attr

Returns the error text that would occur if attribute was modified

MODID

string(2000)

LMI Model ID

MODREF

element

Model reference

MODU

string(120)

Module

MOFI

pos

Moment of Inertia

MOME

real(3)

Moment

MOULEN

real

Mould length

MPEN

integer

Marker pen

MPFIND

element

Find Manufacturingpackage

MPKGFD

element

Find Manufacturingpackage

MPKGFI

integer(500)

Manufacturing Package Filter Expression

MPKGRF

element

Manufacturing Package Reference

MRGF

logical

ADP merge flag

MRGL

word

ADP merge level

MRKLEN

real

Total marking length

MRKR

word

3 way component marker

MRKST

integer

Number of starts for marking

MSESS

integer

attr

Last session number

MSTREF

element

Marker style Reference

MSTYLE

integer

Marker style

MTBE

element

Material tube start. The first component, excluding ATTSs, for whom the LOFF is invalid or false

MTCL

real

Material tube centreline length.

MTEN

element

Material tube end. The first component, excluding ATTSs, for whom the LOFF is invalid or false

MTLE

real

Material tube length for TUBI. Includes preceding bend length if bend is offline.

MTOC

word

Material list control for components

MTOH

word

Material list control for head tube

MTOL

string(1000)

Material List Length

MTOPARTNUMBERS

integer(20)

Additional spooling item part numbers

MTOQ

string(1000)

Material take off quantity

MTOR

element(20)

Extra material list spec references

MTOT

word

Material list control for components leave tube

MTOX

integer(20)

Old spooler addition items

MTXR

element

Material text reference

MTXX

string(2000)

XTEXT of material text

MTXY

string(2000)

YTEXT of material text

MTXZ

string(2000)

ZTEXT of material text

MULT

real

Multiplier factor (unit definition)

MVER

element

Reference to Master Vertex

MYINSF

element

Surface Treatment Reference

MYOUSF

element

Surface Treatment Reference

MYSRFT

element

word

Surface Treatment Reference

N

real

Position northing

NACCNT

integer

Non-additive changes count

NAME

string(500)

Name of the element

NAMEDB

string

DB name

NAMESQ

string(700)

Type. sequence number and name of element

NAMETY

string(700)

Type and name of the element

NAMN

string(500)

Name of the element (without leading slash)

NAMTYP

string(700)

Type and full name of element

NANGLE

real

North angle

NARE

element

Reference to neutral axis

NBEVIT

real(2)

Pathtime except starts, I-bevel

NBEVXT

real(2)

Pathtime except starts, X-bevel

NBEVYT

real(2)

Pathtime except starts, Y-bevel

NBORE

real

Allowable Nominal Bore

NCHAR

integer

Number of label characters

NCOF

pos

Nett centre of gravity

NCOL

integer

Number of columns

NCONNE

integer

Mismatched connections. that is no valid backpointer

NCUTNT

integer

Number of cutouts and notches

NCUTS

integer

Number of cuts in a miterd bend

NDFLT

real

Numeric default value for a UDA

NDTINT

integer(2)

NC tape date

NDTTXT

string(22)

NC tape date text

NGMR

element

Negative geometry set reference

NGSD

integer

Number of GSDs

NHOLE

integer

Number of holes

NIDLAB

real

Pathtime except idle time for label

NIDLT

real(2)

Pathtime except idle time

NLCOLO

integer

Note colour

NLCONU

integer

Note colour number

NLOA

real

Nominal load

NLPN

integer

Note/framing pen

NLSTREF

element

Note linestyle Reference

NLSTRT

integer

Number of label starts

NLSTYL

integer

Note linestyle

NMOF

real(9)

Nett moments of inertia

NOCLIP

logical

View no clipping flag

NOCOL

integer

Number of pin jig columns

NODIMS

logical

No Dims Flag

NOEXTCREATION

logical

Location extract create suppression flag

NOFF

integer

Number off

NOFG

logical

Link constraint inversion flag

NOHLRF

logical

NoHLRFlag

NOISEC

string(104)

Noise category

NOMARK

logical

True if unmarked

NOMBIN

real(200)

word

List of valid Nominal bores in Inches

NOMBMM

real(200)

word

List of valid Nominal bores in MM

NOMREF

element

Nominal bore table reference

NOMXRF

element(500)

Return reference from NOMTAB element to SPECs

NOPGS

integer

Number of openings

NORM

dir

Plane normal

NOROW

integer

Number of pin jig rows

NORTHING

pos

Northing part expressed as a position

NOSOFF

real

Nosing Offset

NOTF

element

Cross-reference to NOTE/VNOT/SYTM

NOTREAD

integer(10)

Number of treads

NPDESC

element(5000)

List of non primary offspring

NPILL

integer

Number of jig pillars

NPLDFA

string(80)

Nesting default file 1

NPLDFB

string(80)

Nesting default file 2

NPLIST

element(500)

All NATPs attached to route node

NPLMIR

integer

Quantity mirrored nested plates

NPLNOR

integer

Quantity normal nested plates

NPLTOT

integer

Total quantity nested plates

NPOS

pos

Position in owner

NPOSE

real

Easting of position wrt owner

NPOSN

real

Northing of position wrt owner

NPOSU

real

Upping of position wrt owner

NPPT

integer

Ppoint number

NPRSID

string(26)

Side of nested profile

NPRVEC

real(2)

Local rotation vector of part

NPSIDE

string(80)

Side of nested part

NPXYP

real(2)

Local position of part

NREL

integer

Nodal releases

NROW

integer

Number of rows

NRPARM

integer

Number of rest plate parameters

NRULEE

integer

Number of rule inconsistencies on element

NSIZ

real

Nominal size

NSPE

element

Specification for NOZZLE

NSRF

real

Nett surface area

NSTART

integer(2)

Number of non-burning starts

NSTD

element

Non-standard bolt length (reference to DTAB)

NSTFAC

real

Number of starts - factor

NSTRT

integer(3)

Number of burning starts

NSTRTI

integer(2)

Number of burning starts I-bevel

NSTRTX

integer(2)

Number of burning starts X-bevel

NSTRTY

integer(2)

Number of burning starts Y-bevel

NTEXT

string(12)

Null text

NTRLEN

real

Neutral length

NUCDNA

real

Distance to nearest anchor

NUCDNE

real

Distance to the Nearest Edge

NUCDNR

element(2)

Nearest Adjacent Anchor

NUMB

integer

Number

NUMBDB

integer

DB number

NUMCOR

integer

Number of cores in a cable

NUMOFF

integer

Number of Sheets in Drawing

NUSED

integer

Number of used raw plates

NVIEWF

string(73)

integer

Neutral viewer filename

NVOL

real

Nett volume

NWEI

real

Nett weight

NWELDS

integer

Number of attached welds on a piping component

NXTDBN

integer

Next DB number

NXTDBU

integer

Next Unique DB number

NXTEXN

integer

Next DB extract number

NXTFDB

integer

Next DB file and DB number

NXTFLN

integer

Next DB file number

NXTHB

element

Reference to next (future) hub

NXTKEY

integer

next UDA/UDET key

OANG

real

Overlay sheet angle

OBCOLO

integer

Obscured face colour

OBCONU

integer

Obscured face colour number

OBFG

logical

Obstruction flag

OBJCD

integer(2)

Object codes

OBPN

integer

Obscured face pen

OBST

integer

Obstruction level

OBSTREF

element

Obscured face linestyle Reference

OBSTYL

integer

Obscured face linestyle

OCCTYP

string(50)

Occupancy Type

OCCUPA

real

Occupancy

OCOD

string

Hashed origin code

OCONE

integer

Objectcode 1

OCTWO

integer

Objectcode 2

OD

real

Outer Diameter

ODESP

real(100)

Owning design parameters

OFFDIR

dir

Offset direction applied to repeat

OFFDIS

real

Offset distance applied to repeat elements

OFFSET

real

Offset

OFFTOL

string(1000)

PPoint offset tolerance

OFFTYP

word

Offset type: DELTA, LINEAR, RADIAL

OGDSTS

real(25)

Distances to openings

OGOING

real

Overall Going

OKCLA

logical

True if element may be claimed

OKCLH

logical

True if element and hierarchy may be claimed

OKDROP

logical

True if element may be dropped

OKDRPH

element(5000)

Primary elements preventing hierarchy drop

OKREL

logical

True if element may be released

OKRLEH

element(5000)

Primary elements preventing hierarchy release

OKRLEX

logical

True if element may be extract released

OKRLH

logical

True if element and hierarchy may be released

OLCOLO

integer

Outline colour

OLCONU

integer

Outline colour number

OLDKEY

integer

Old key

OLENGTH

real

Overall length

OLIS

word(2000)

List of all possible owner types

OLOFF

real

OffsetLine offset from baseline

OLPEN

integer

Outline pen

OLSTREF

element

Outline linestyle Reference

OLSTYL

integer

Outline linestyle

OMITFG

logical

Omission flag

ONPJ

pos

Owning neutral point of joint (steelwork)

ONPO

real(2)

ONTO Point, position of view in the region

ONPS

pos

Owning neutral point of section (steelwork)

OPAR

real(100)

Owning parameters - catalogue component

OPCLA

word

Claim Access Control Operation

OPCOP

word

Copy-From Access Control Operation

OPCRE

word

Create Access Control Operation

OPCREF

element

Offpage connector reference

OPDEL

word

Delete Access Control Operation

OPDI

dir

Origin plane direction

OPDRO

word

Drop Access Control Operation

OPERAT

string(26)

Operator

OPEXP

word

Export Access Control Operation

OPHEIG

real

Operational Height

OPISS

word

Issue Access Control Operation

OPLENG

real

Operational Length

OPMOD

word

Modify Access Control Operation

OPNSIZE

real(2)

Opening size

OPOS

pos

Overlay sheet position

OPOUT

word

Output (DATAL) Access Control Operation

OPREMA

real

Operating pres. max

OPREMI

real

Operating pres. min

OPTEMP

real

Operational temperature

OPWIDT

real

Operational Width

ORI

ori

Orientation

ORIA

real(3)

Orientation as angles

ORIF

logical

Orientation flag

ORIN

word

DRAFT user defined symbol orientation

ORISE

real

Overall Rising

ORNA

string(1000)

Originator text

ORRF

element

Origin reference (for templates)

OSDWG

string(120)

AutoCAD overlay name

OSET

logical

Offset/VIEW position flag

OSFN

string(1024)

Overlay sheet file

OSHT

real

Overshoot

OSLV

real(12)

Overlay sheet view layers visible

OSRF

element

Overlay sheet ref

OSTYPE

word

Short cut for "Type of owner"

OTHLEN

real

Length of other intervals

OTHNUM

integer

Number of other intervals

OTMPMA

real

Operating temp. max

OTMPMI

real

Operating temp. min

OUAREA

real

Area of outer contour

OUPRTR

element

Outside paint reference

OUTD

string(1000)

Outside diameter

OUTFRF

element

Reference of matching outfit object

OUTSD

string(1000)

Outside shield diameter

OVCWIDTH

real

Overall cables width

OVRSH

real

Overshoot (d-measure) for unsymmetrical flange

OWNC

word

Owning connection type

OWNER

element

Element owner in database hierarchy

OWNEXPRESSION

string(4000)

Owner expression

OWNEXTYPE

string(60)

Owner expression type

OWNLST

element(100)

Owning hierarchy

PAAX

string(30)

Direction of axis

PAGE

integer(500)

Page in diagram

PAINTO

string(26)

Painting other side

PAINTT

string(26)

Painting this side

PAIREF

element

Reference to a PAINT element

PALIG

real

Panel alignment

PALLAN

real

integer

Ppoint allowed angle

PANESI

real(2)

Panel Size

PANG

string(1000)

Angle subtended

PANREF

element

Panel reference

PANSCD

integer

Panel storing code

PANSID

integer

Side of panel

PANSTC

integer

Panel storing code

PARA

real(100)

Parameters

PARAL

logical

True if tap parallel to referred seam

PARCOLUMN

element

Parent column

PARENT

element

elemtype

Reference of ascendant element of specified type

PARM

real(6)

Parameters

PARNAM

string(256)

Part name

PARREF

element(10)

Part reference

PARTNUMBER

integer

Part number of a spooled component or leave tube

PASS

string(7)

Password

PASSQ

integer

Password Quality

PATADV

real

Line Pattern Advance value

PATDEF

integer(20)

Pattern Definition

PATH

element(500)

Path

PATHTM

real

Path time for selected burning machine

PATNAM

string

Pattern Name

PATOFF

real

Line Pattern Offset

PATREP

real

Pattern Repeat

PAXI

string(30)

Axial direction

PBAX

string(30)

Direction

PBBT

string(1000)

Bottom B length

PBDI

string(1000)

Distance to bottom surface

PBDM

string(1000)

Snout bottom diameter

PBENDNUMBER

integer

Spooling pulled bend number

PBOF

string(1000)

B offset

PBOP

pos

integer

Bottom of pipe

PBOR

string(1000)

Bore

PBTP

string(1000)

Top B length

PCAX

string(30)

Direction of C offset

PCBT

string(1000)

Bottom C length

PCODA

integer

Precision code angles

PCODE

integer

Precision code

PCODF

integer

Precision code fractions

PCODI

integer

Precision code imperial

PCODM

integer

Precision code metric

PCOF

string(1000)

C offset

PCON

string(1000)

Connection type

PCONDE

string(120)

integer

Ppoint connection description

PCORRO

real

integer

P Tube corrosion

PCPIDV

element(10000)

Enabled for project copy

PCPSET

element(10000)

Enabled for project copy

PCREF

integer(4)

integer

Ppoint and ref of connected piping component

PCRFA

element(500)

All spools that contain this element

PCTP

string(1000)

Top C length

PCWALL

real

integer

Ppoint connect wall thickness

PDAREF

element

Pipe data table reference

PDEFI

string

Primitive Definition

PDEREF

element

integer

Pipe data element reference

PDIA

string(1000)

Diameter parameter

PDIR

dir

integer

Ppoint direction

PDIS

string(1000)

Distance parameter

PDTINT

integer(2)

Production date

PDTTXT

string(22)

Production date text

PERS

real

Perspective angle

PFLALL

string(1000)

Flange allowance parameter

PFLOFF

string(1000)

Flange offset parameter

PFON

integer

Projection line text font

PFONTN

string(80)

Projection line text font name

PFRE

element

Pfitting reference for Cofittings

PFREQ

logical

Picture file required flag

PGRD

real

integer

Ppoint gradient

PHBO

real

Pipe head bore

PHBP

pos

Bottom of pipe head

PHCO

word

Pipe head connection type

PHDR

dir

Pipe head direction

PHEI

string(1000)

Height

PHGR

real

Pipe head gradient

PHOD

real

Pipe head outside diameter

PHPO

pos

Pipe head position

PHTP

pos

Top of pipe head

PICF

string(73)

Picture filename

PICFD

logical

Picture file distribution flag

PICHTY

word

Hard type of picture

PICSTY

word

Soft type of picture

PINDEN

real

Pin Density

PIPSYM

logical

Pipe-end symbol flag

PITCH

real(10)

Pitch of stair flight

PITCHO

real

Angular offset from ladder pitch

PJUS

string

Projection line text justification

PKDI

real

Proportional distance along Pline

PKEY

word

Pline identifier key

PLALEN

real

Raw plate length

PLANU

string(1000)

Planning Unit

PLANV

logical

Is Plan View

PLAREA

real

Area

PLATYP

string(26)

Type of plate , for example. Plate, Bracket, Clip,...

PLAWDT

real

Raw plate width

PLAX

string(120)

2D direction angle

PLCL

real

Projection line clearance

PLCLFL

logical

Proj. line clearance flag

PLCN

logical

word

Pline centreline flag

PLCO

word

word

Pline connection

PLCOLO

integer

Projection line colour

PLCONU

integer

Projection line colour number

PLDE

string(120)

word

Pline description

PLDI

real(3)

Projection line direction

PLED

dir

Plane entry direction

PLEN

pos

word

Pline end

PLENCU

pos

word

Pline end, allowing for cutback

PLFG

logical

Plines flag

PLINON

logical

Pline-required flag

PLLE

integer(2)

word

Pline level

PLLS

word(100)

List of valid Plines

PLNA

word(100)

List of available Pline names

PLNCOL

integer

Pline colour

PLNCON

integer

Pline colour number

PLNP

integer

Pline pen

PLNSTREF

element

Pline linestyle Reference

PLNSTY

integer

Pline linestyle

PLOR

ori

word

Pline orientation

PLPM

word

Plane pipe packing method - nearest or weighted

PLPN

integer

Projection line pen

PLPP

word

Plane pipe positioning code word used by Router

PLPU

word

word

Pline purpose

PLRD

dir

Plane routine direction

PLREFS

element(5000)

Pline references

PLRF

element

Plane reference

PLSP

real

Projection line text line spacing

PLST

pos

word

Pline start

PLSTCU

pos

word

Pline start, allowing for cutback

PLSTREF

element

Projection linestyle Reference

PLSTYL

integer

Projection linestyle

PLTU

logical

word

Pline tube flag

PLTX

string(1000)

Projection line text

PLVI

word(200)

List of visible Plines

PLVIF

integer

word

Pline visibility flag

PLWW

word

Plane wall to wall positioning code used by Router

PMAX

integer

Maximum part number in current spool drawing

PMLFUN

string(120)

PML Function name

PMLNAM

string(120)

Name of Pmlobject

PMOD

string

Plane mode

PNAM

string(12)

Property description

PNTUV

pos

Point2D

PNTXYZ

pos

Point3D

POCK

word

Is a branch component in a pocket

POD

real

integer

Ppoint outside diameter

POEF

logical

Post-evaluation flag

POFF

string(1000)

Offset

POINUM

integer

Point Num

POIS

real

Spot value of Poissons ratio

POITYP

string(120)

Point type

POS

pos

Position

POSE

pos

End point position

POSEE

real

Easting of end point position

POSEU

real

Upping of end point position

POSEV

pos

Position evaluation

POSEY

real

Northing (Y coordinate) of end point position

POSF

logical

Positioning flag

POSFOR

string

Intelligent Text positional code word expansion style

POSL

word

Positioning line

POSN

real

Northing of position

POSNO

integer

Position number

POSREF

element

Reference to point

POSS

pos

Start point position

POSSE

real

Easting of start point position

POSSN

real

Northing of start point position

POSSU

real

Upping of start point position

POSTSP

real

Default post spacing

POSU

real

Upping of position

POSX

real

Easting (X coordinate) of position

POSXP

integer(500)

Position expression

POWFAC

real

Powder point factor

PPANFL

real

Pipe Piece Angle between flanges

PPAREF

element

Pipe Piece Arrive Reference

PPBO

real

integer

Ppoint bore

PPBRAD

real(500)

Pipe piece bend radii

PPBRAT

real(500)

Pipe piece bend ratio

PPCNBD

logical

Pipe piece contains bends

PPCO

word

integer

Ppoint connection type

PPCOU

integer

Number of valid Ppoints

PPCUTL

real

Cut Length

PPDE

string(120)

integer

Ppoint description

PPDI

integer

Ppoint number for direction

PPEFR

logical

Leave flange required

PPER

element

Pipe piece end reference

PPEXST

logical

integer

True if Ppoint exists

PPFINL

real

Finished Length

PPFMCV

logical

Pipe piece fabrication machines verified

PPHEI

real

integer

Ppoint height

PPLREF

element

Pipe Piece Leave Reference

PPLS

integer(200)

List of valid Ppoints

PPMODI

logical

Pipe piece modified

PPNU

integer

Design PPoint/Port number

PPOFFT

real

integer

Ppoint offset

PPOS

pos

integer

Ppoint position

PPRFA

element(500)

All components in the PipePiece

PPRO

string(1000)

parameterized Property Expression

PPSFR

logical

Arrive flange required

PPSK

word

integer

Ppoint pskey

PPSPEC

element

Pipe Piece Specification

PPSR

element

Pipe piece start reference

PPUR

word

integer

Ppoint purpose

PPVBMC

element

Return the bending machine IF the pipe piece is verified

PPVERI

word

Pipe piece verified

PPVI

integer(200)

List of visible Ppoints

PPVIF

integer

integer

Ppoint visibility flag

PPVWMC

element

Return the welding machine IF the pipe piece is verified

PPWID

real

integer

Ppoint width

PQAANG

real

integer

Angle between alignment direction of specified pp and adjacent component

PQANG

real

integer

Angle between specified Ppoint and adjacent component

PQBORE

logical

integer

TRUE if specified Ppoint has same bore as adjacent

PQCON

logical

integer

TRUE if leave Ppoint has Correct connection type

PQOFF

real

integer

Offset between specified Ppoint and adjacent component

PQUA

word

Property qualifier

PRAD

string(1000)

Radius

PRAV

real

Average pressure

PRDE

string(250)

word

Property default

PREF

logical

Pre-evaluation flag

PREFIX

string(120)

Prefix

PREPPR

string(26)

Preparation information

PREPT

real

Preparation time

PRES

real

Pressure

PRFC

string(1000)

Pressure factor

PRFELE

element

Cableway profile element

PRFG

logical

Profile flag

PRFL

string(120)

Profile

PRFOBS

integer

Cableway profile obstructions

PRICEE

real

Price estimate

PRIMDB

string

Global status of DB, primary or secondary

PRIMEM

logical

Primary member

PRIMSY

element

Reference of the primary system elements

PRIMTY

logical

True if element is primary

PRITYP

string(120)

Gpart Primary type

PRJD

string(180)

Project description

PRJID

string(8)

Project id. Available on STAT or GSTAT element

PRJL

logical

Project lock

PRJN

string(17)

Project number

PRJSTA

word

Access Control project status

PRLS

word(100)

List of valid properties - catalogue or design

PRMA

real

Maximum pressure

PRMDIR

dir

Primary Direction

PRMI

real

Minimum pressure

PRMLOC

element

Primary location

PRMMEM

logical

True if there are any primary elements amongst descendants

PRMOWN

element

Primary owning element (will be itself if primary)

PRMRF

element

Primary Location Element

PRMVI

logical

Draughting primitive visibility

PROCDE

string(2400)

PROCess DEscription

PRODID

string(104)

Product id

PRODRF

element

Reference to Production Object

PRODUCTION

real

Production level radiation

PROJID

integer(3)

PROJID - on the DB element

PROLEN

real

Raw profile length

PROMIX

integer

Index of Promote Status Value

PROMPT

string(160)

User prompt

PROP

string(250)

word

Property value from catalogue or design dataset

PROPG

logical

DB propagation flag

PROPRE

real

attr

Calculated Property Real Attribute

PROSID

integer

Plate side with most profile markings

PRPU

word

word

Property purpose

PRTI

string(120)

word

Property title

PRTIDL

string(132)

Long part id

PRTIDM

string(132)

Module part id

PRTIDS

string(132)

Short part id

PRTLST

string(26)

Parts list name

PRTREF

element

Part reference

PRTRTX

string(1000)

word

Part element R text

PRTSTX

string(1000)

word

Part element S text

PRTTTX

string(1000)

word

Part element T text

PRTXRF

element(500)

Return reference from PART element to SPCOs

PRVRF

element

Reference to previous owner of DB

PRVSES

integer

integer

Previous Session to that specified

PSARFA

element(500)

Pipespool arrive references

PSATTS

word(500)

List of pseudo attributes

PSESS

integer

integer

Previous session number

PSFG

logical

Piping component symbol flag

PSIZE

real(2)

Panel size

PSKE

word

Key for ISODRAFT

PSLRFA

element(500)

Pipespool leave references

PSPE

element

Pipe specification

PSPIN

integer

Ppoint number showing position of spindle

PSTAT

integer

Plane status

PSTF

element

Pointset reference

PSTR

element

Structural Pline set reference

PSTYP

word

Spool Type

PSVLD

logical

Pipespool valid

PTAN

string

Projection line text angle flag

PTBO

real

Pipe tail bore

PTBP

pos

Bottom of pipe tail

PTCDI

string(1000)

parameterized direction

PTCH

real

Projection text character height

PTCO

word

Pipe tail connection type

PTCOLO

integer

Projection text colour

PTCONU

integer

Projection text colour number

PTCPOS

string(250)

parameterized position

PTDI

string(1000)

Distance to top surface

PTDM

string(1000)

Snout top diameter

PTDR

dir

Pipe tail direction

PTDTRE

element

Part Data set reference

PTEM

real

Pipework temperature

PTEPOS

string(250)

parameterized end position

PTFA

element(17)

Point references

PTGR

real

Pipe tail gradient

PTLH

real

Projection text letter height

PTNB

integer(20)

Old spooler bolt part number

PTNH

integer

Old spooler head tube part number

PTNO

integer

Old spooler component part number

PTNT

integer

Old spooler tube part number

PTOD

real

Pipe tail outside diameter

PTOF

real(2)

Projection line text offset

PTOLER

real

Tolerance on a design property

PTOP

pos

integer

Top of pipe

PTPN

integer

Projection text pen

PTPO

pos

Pipe tail position

PTPTXT

string(26)

Profile type. for example. Stiffener, Flange,...

PTRE

element

Point set reference

PTRF

element

Point reference

PTS

integer(6)

Line definition points

PTSP

string(120)

Paint specification

PTSPOS

string(250)

parameterized start position

PTTP

pos

Top of pipe tail

PTYP

word

Property type

PUCD

string(100)

Paint Code

PUINCD

string(120)

Inside punch code

PUNCHT

real

Punching time

PUNI

string(32)

Data Property Units

PUOUCD

string(120)

Outside punch code

PURCH

string(26)

Purchase information

PURP

word

Description code word

PVIF

integer

PPoint/Pline visibility filter

PVNO

integer

Picture version number

PWALLT

real

integer

Ppoint wall thickness

PWAS

string(1000)

Percentage wastage factor

PWID

string(1000)

Width / Wall thickness

PWWFAC

real

Powder way factor

PX

string(1000)

Cartesian X position

PXBS

string(1000)

Inclination of bottom surface to local X axis

PXLE

string(1000)

X length

PXTS

string(1000)

Inclination of top surface to local X axis

PY

string(1000)

Cartesian Y position

PYBS

string(1000)

Inclination of bottom surface to local Y axis

PYLE

string(1000)

Y length

PYTS

string(1000)

Inclination of top surface to local Y axis

PZ

string(1000)

Cartesian Z position

PZAXI

string(30)

Alignment axial direction

PZDIR

dir

integer

Ppoint alignment direction

PZLE

string(1000)

Z length

QALLSI

integer

AllocSize

QMXUPT

integer

MaxUserPtr

QNELEM

integer

QNoElem

QOBJSI

integer

ObjectSize

QTYPE

word

Type of question

QUACD

integer

Quality code

QUAL

integer

Qualifier

QUAN

integer

Quantity (always one!)

QUAPAI

string(26)

Paint specification

QUATXT

string(26)

Quality

QUES

word

Question

QUSEXP

integer(250)

question expression

RADD

real

Default Radius value

RADF

real

Radius attractor factor

RADI

real

Radius

RADISP

real(10000)

Radius Spacing

RADL

real(2)

Radius limits (Min/Max)

RADS

logical

Radius set flag - ignore Radius values if FALSE

RAILHE

real(15)

Heights of rails measured from path

RAILTR

real(10000)

Rail Trim

RANANG

real(32)

elemtype

Range of available angles for bends and elbows

RANEQUIP

real

Range of the nearest equipment

RANRAD

real(32)

elemtype

Range of available radii

RATFAC

real

Rationalisation factor

RATI

real

Pressure rating

RATPOT

string(15)

Rationalisation post text

RATPRE

string(15)

Rationalisation pre text

RATTAL

element(500)

word

Ratta list

RATTAL

element(500)

word

Rnode list

RAWNAM

string(500)

Name only

RAWPLA

element

Raw Plate

RAWPRO

string(26)

Name of raw profile

RCOD

string

Direction of region vertical on sheet

RCOF

pos

Rough centre of gravity

RCOU

integer

Number of rules on element

RDEF

real(3)

Port rotation flexibility defaults

REACT

string(1000)

Reactance

READONLY

logical

Read only

REALEV

real

Real evaluation

REALXP

integer(500)

Real expression

RECOMM

string(256)

Release to 3D comment

REDATE

string(12)

Release to 3D date

REDREF

element

Reducer table reference

REDTYPE

integer

Reducer Type

REDXRF

element(500)

Return reference from Reducer Table element to SPECs

REF

element

Reference of the element

REFA

word

Reference attribute used in ports

REFI

integer

Reference array index

REFL

word(200)

Types of elements (including UDETs) that can be pointed to by a reference attribute

REFLCL

logical

True if reflected in CL

REFLEVEL

integer

Reference Level

REFMOD

integer

Reflection Mode

REFSIZ

integer

Reference size

REPCOU

integer

Rule Repeat Counter

REPSEQ

integer

Sequence no. for template repeat element

REPTXT

string

Reporter text used for element type

REQUIRED

logical

Required

RESIS

string(1000)

Resistance

RESO

real

Model Resolution (distance)

RESTAT

integer

Release to 3D status

REUSER

string(50)

Release to 3D user

REV

integer

Pipe Revision number

REVDIR

logical

Reverse Direction flag

REWIDTH

real

Reduced width

RFLAG

word

Type of real answer NONE, SINGle, RANGe or MULTi

RFLF

real(3)

Rotational spring values

RGBCOL

real(3)

RGB colour vector

RHOST

string(120)

Host computer name or IP address of remote machine

RINE

real(3)

Rotational inertia vector

RINS

real

Inside radius

RISE

real

Tread Rise

RLAC

integer(500)

Rule action array

RLEX

element(20)

Array of references of special rules to exclude

RLIM

real(6)

Rotation limits

RLIN

element(20)

Array of references of special rules to include

RLIS

word(200)

List of rules set

RLLO

integer(500)

Rule logical array

RLOC

integer

Branch Member Creation Status code (Router)

RLSE

integer(500)

Rule selection array

RMFL

real(6)

Rotational moment flexibility

RMOF

real(9)

Rough moments of inertia

RNAM

string(120)

Recipient name

RNGCON

element

Rung Connection

RNGOFF

real

Rung Offset

RNREF

element

Route Node reference

RNRIDF

real

Rung Rising Default

RNRIMA

real

Rung Rising Minimum

RNRIMI

real

Rung Rising Minimum

RNTYPE

word

RNode Type

ROBRRU

element(500)

Router Rules applying to a piping element or members

ROLEREF

element

Access Control role references from ACR

ROOMTY

string(120)

Room Type

RORIEN

logical

True if repeat item is re-orientated upon rotation

ROTN

real(3)

Rotation

ROUT

real

Outside radius

ROUTND

element(100)

Cable Preliminary route point

ROUTRE

element

Route reference

ROWCOL

integer

Row colour

ROWCON

integer

Row colour number

ROWNUM

integer

Pin row number

ROWSTREF

element

Row linestyle Reference

ROWSTY

integer

Row linestyle

RPARM

real(4)

Rest plate parameters

RPEN

integer

Pen for internal rows

RPLCOD

integer

Rest plate code

RPLNAM

string(26)

Rest plate name

RPLNUM

integer

Number of rest plates

RPLPOS

real(4)

Rest plate position

RPLSET

integer

Rest plate set

RPLTYP

integer

Rest plate type

RPRE

real

Reference pressure

RPRO

real

word

Catalogue dataset property

RPTX

string(20)

Text used when presenting the attribute to the user

RRSF

element

Rep ruleset reference

RSBOX

real(6)

Bounding box of RSO

RSEQA

integer(500)

Sequence numbers for rule execution

RSEQFA

element(500)

Rule sequence ref array for local names

RSEQN

integer

Sequence number for rule execution

RSESS

string(120)

integer

Reason for creation of session

RSET

logical(3)

Rotation limits set flag - ignore values if FALSE

RSFFD

integer

Functional description on face

RSFMC

integer

Material code on face

RSFMS

string(256)

Material side on face

RSFMT

real

Material thickness on face

RSFSA

logical

Auto stiffening on face

RSFSD

string(256)

Profile dim on face

RSFSS

string(256)

Stiffener side on face

RSFST

integer

Profile type on face

RSFWT

logical

Watertight

RSLBRA

string(256)

Bracket instance at limit

RSLELE

element

Limiting element

RSLPRE

integer

Profile end definition at limit

RSPAN

element(1000)

Panel(s) defined on RSO

RSPLN

integer

Principal plane of RSO

RSRF

real

Rough surface area

RSTYP

integer

Type of RSO

RTEM

real

Reference temperature

RTEX

string(2000)

R Text string

RTYP

string(12)

Restraint type

RULEER

string(300)

integer

Text of "nth" rule error

RULEMOD

logical

attr

True if rule modified this session

RULEMODC

logical

attr

True if rule modified since comparison date

RULEMODLIST

word(500)

integer

List of rules modified since given session

RULEMODLISTC

word(500)

List of rules modified since comparison date

RULLIM

real(6)

Ruler limits

RULRCO

integer

Ruler type code

RULSET

word(2000)

List of rules set

RULTCK

integer

Number of ticks between labelled ticks

RUNGS

integer

Number of rungs

RUNGSP

real

Rung Spacing

RUSE

integer

True if PPROP/DPROP to be used as an RPROP in geomset/pointset attribute expression

RVAU

string(1000)

Revision author

RVDT

string(12)

Date of revision

RVOL

real

Rough gross volume

RVSN

string(1000)

Revision number

RVTM

string(120)

Time of revision

RWDOWN

integer(2)

Table linking RWELD elements to design WELD elements

RWDOWN

element

Reference of associated WELD of RWELD element

RWEI

real

Rough weight

RWIDTH

real

Rung Width

S

real

Position southing

SAFC

integer

Safety class

SAVDIR

dir

Cached direction

SAVPOS

pos

Cached position

SBRA

element(10)

SBOLT references

SBRP

element

SBFR to RPLA reference link (Router)

SCAL

integer

DRAFT user defined symbol scale factor

SCALI

real(500)

ADP main view allowable scale list

SCALIN

logical

Drafting symbol link scaling flag

SCALPH

logical

ALPHA/NOALPHA flag

SCAREF

element(10)

Area shape reference

SCBREF

element(50)

Schematic element back reference

SCDELI

string(50)

Delimiter

SCDIGIT

integer

Digits

SCEIRE

element(60)

Enhanced instrument relationship

SCELOR

element(20)

Enhanced instrumentation loop reference array for schematic elements

SCGTYP

string(50)

Schematic nozzle gtype

SCHED

string(10)

Piping Schedule

SCHELE

element

Schematic head element

SCHEME

string

Scheme name

SCHFF

integer

Schematic file format

SCHLNK

element

Connectivity Schematic Link

SCHTYP

integer

Schematic type

SCIERTYPE

word(60)

Instrument enhanced reference type

SCIIRE

element(50)

Instrument to instrument reference

SCIIRTYPE

word(50)

Instrument to instrument reference type

SCIPRE

element(50)

Instrument process reference

SCIPRTYPE

word(50)

Instrument process reference type

SCIREF

element(10)

Instrument reference

SCIREL

element(50)

Instrument relationship

SCIRLTYPE

word(50)

Instrument relationship type

SCIRTY

word(10)

Instrument reference type

SCLORE

element(10)

Instrumentation loop reference array for schematic elements

SCOD

string(3)

Isodraft Compipe: Short code

SCOPEREF

element

Access Control scope references from ACR

SCOSEL

integer(500)

Access Control scope

SCOSLX

integer(500)

Access Control scope

SCPANA

string(120)

Schematic page name

SCPATY

word

Schematic page type

SCQUAN

integer

Quantity

SCRAPT

real

Total scrap of raw plate area

SCRAPU

real

Total scrap of used raw plate area

SCREF

element

Schematic element reference

SCSTYP

string(257)

Schematic stype

SCSYSD

element(500)

System reference array for schematic diagrams

SCSYSF

element(10)

System reference array for schematic elements

SCTDIR

dir

Section Direction

SCTELE

element

Schematic tail element

SDISTA

real

Vertical Distance of Start

SDTH

real(3)

Saddle thickness

SDTINT

integer(2)

Splitting date

SDTTXT

string(22)

Splitting date

SECTYP

string(120)

Gpart Secondary type

SEGE

pos

Segment end point position

SEGS

pos

Segment start point position

SENS

string

Rotational sense

SEQU

integer

Sequence Position in Member List

SESCLA

integer

Session Of Claim

SESSC

string(120)

integer

Comment for specified session

SESSCA

integer(2000)

List of pairs of DB number, last session number for all referenced DBs

SESSCH

integer(2000)

As for SESSCA, but searches all descendants for referenced DBs

SESSD

string(120)

integer

Date of specified Session

SESSM

integer

attr

Session Of Last Modification

SESSNO

integer

Current opened Session

SESSU

string(120)

integer

User creating specified session

SETDATE

string(120)

Set Date

SEXPND

element(10000)

All descendant elements in secondary hierarchy

SFCODE

integer

Stiffener Code

SFLIMI

word

Spooling limits

SFOR

real(3)

Start force vector component

SFREF

element

Return reference from piping component or leave tube to spool or field element

SHAP

string(1000)

Shape modulus

SHFALG

real

Shrinkage factor along main direction

SHFPRP

real

Shrinkage factor perpendicular to main direction

SHFSEA

real

Shrinkage factor for seams perp. to main direction

SHIPNO

string(80)

Ship number

SHIPX

string(20)

Ship X position

SHIPY

string(20)

Ship Y position

SHIPZ

string(20)

Ship Z position

SHOC

real(3)

Shock load vector

SHOP

logical

Shop/Site flag

SHOPRI

logical

Shop Primer

SHPSYM

string(40)

Shape symbol text

SHPUV

pos

Point defining shrinkage

SHRF

element

Reference to associated sheet or library

SHTNUM

integer

Sheet Number

SHVUV

dir

Vector defining shrinkage

SIF

real(3)

Stress intensification factor

SIGF

integer

Significant figures

SIGREF

element

Significant point reference

SITEM

element

Reference from secondary hierarchy

SIZE

real(2)

Sheet/region size

SIZEDB

integer

Size of DB

SJUS

word

Surface justification for PALJs

SKEY

string(4)

Symbol key

SKEYSCALE

integer

Universal SKEY scale factor

SLENGTH

real

Side length

SLOPEF

logical

SLOPEF (True if its a sloping wall else step change)

SLOREF

element

Pipe slope reference

SLRAP

element(500)

Sorted list of RATTA after POINTR

SLRBP

element(500)

Sorted list of RATTA before POINTR

SMAX

integer

Maximum spool number in current spool drawing

SMEMB

element(10000)

Immediate members in secondary hierarchy

SMNO

integer

SMODU number

SMOD

string

Sectioning mode

SMOM

real(3)

Start moment component

SOLFILLED

logical

Solid Filled Flag

SORF

element

Source reference (for automatic application)

SOUR

string(1000)

Source macro

SPBREF

element

Reference to boundary element

SPECIF

logical

True if outer panel contour on PS/SB are different

SPIN

string(4)

DRAFT user defined spindle symbol/skey name

SPINRE

element

Reference to external inventory element

SPKBRK

logical

ATTA flag to treat as a real element

SPKCHG

element

flag to show where a spec change occurs in a branch

SPKDI

real

Proportional distance of start point along Pline

SPLA

string

Name of spigot plate

SPLATE

word

Section plate

SPLH

string(120)

Old spooler head tube spool number

SPLMEM

element(1500)

Spooling table attribute on SPOOL or FIELD elements

SPLN

string(120)

Old spooler component spool number

SPLNUM

integer

Spool number

SPLP

string(120)

Spool number prefix

SPLPARENT

element(500)

elemtype

Branches referenced by a SPLDRG, SPOOL or FIELD

SPLT

string(120)

Old spooler tube spool number

SPLTBL

integer(2000)

Table linking SPOOL & FIELD elements to piping components

SPLVOLUME

real(3)

Volume of a SPOOL element

SPMA

real

word

Spec angle maximum answer

SPMACC

string(25)

Access authorization code

SPMACD

string(75)

Access authorization description

SPMALL

real

Structural Allowance

SPMAOF

real

Offset AFT

SPMARA

real

Area of face

SPMARE

real

Area of face

SPMATP

integer

Type of space arrangement

SPMBB

real(6)

Bounding box

SPMBIN

integer

Boundary identification number

SPMBNA

string(80)

Boundary name

SPMBOF

real

Offset BOT

SPMBOX

real(6)

Bounding box

SPMBR

element

Bounding reference

SPMCAS

real

Calculated steel paint area of space contents

SPMCDE

string(75)

Content description

SPMCFA

real

Floor area

SPMCLI

word(2000)

List of customer attributes for space

SPMCOL

integer

Colour

SPMCOS

real(3)

Calculated centre of steel structure

SPMCOV

pos

Centre of Volume

SPMCTY

string(25)

Content type code

SPMCWB

real

Calculated length of butt weld

SPMCWC

real

Calculated Weight of space Contents

SPMCWL

real

Calculated length of fillet weld

SPMCWS

real

Calculated Weight of steel structure

SPMDE

real

Density

SPMEAS

real

Estimated steel paint area of space contents

SPMEHC

real

Estimated HVAC Capacity

SPMEN

string(26)

Envelop name

SPMEPC

real

Estimated Power Consumption

SPMEWB

real

Estimated length of butt weld

SPMEWC

real

Estimated Weight of space Contents

SPMEWL

real

Estimated length of fillet weld

SPMEWS

real

Estimated weight of steel structure

SPMFAR

real

Face area

SPMFCL

string(20)

Fire class

SPMFLW

real

Full load weight

SPMFOF

real

Offset FWD

SPMFST

integer

Face state

SPMHSN

string(26)

Hull surface name

SPMLSC

string(25)

Space Category

SPMMVO

real

Total (moulded) volume

SPMNBI

integer

Next boundary identification number

SPMNOC

string(25)

Noise category code

SPMNOD

string(75)

Noise category description

SPMNVO

real

Net volume

SPMPED

real

Permeability Damage

SPMPER

real

Permeability

SPMPOF

real

Offset PS

SPMPP

real(5)

Precise properties

SPMPU

string(25)

Purpose code

SPMRDH

real

Required deck height

SPMRFA

real

Required floor area

SPMRSE

string(25)

Required service code

SPMRSN

string(26)

Reference surface name

SPMRTE

element

Reference to envelop space

SPMSAC

string(25)

Safety category code

SPMSAD

string(75)

Safety category description

SPMSAN

string(80)

Space arrangement name

SPMSBD

element(500)

Space boundary definitions

SPMSEC

string(25)

Security classification code

SPMSED

string(75)

Security classification description

SPMSFI

integer

Subface identification number

SPMSFP

element

Returns the space that contains the given point

SPMSOF

real

Offset SB

SPMSS

integer

Space state

SPMSTP

integer

User defined subtype

SPMSWT

integer

Type of space world

SPMTHC

string(25)

Thermal insulation code

SPMTHD

string(75)

Thermal insulation description

SPMTIC

string(25)

Compartment tightness code

SPMTID

string(75)

Compartment tightness description

SPMTOF

real

Offset TOP

SPMTOL

integer

Type of limits

SPMTYP

string(20)

Type of space world as enumerated

SPMVOI

integer

Space void marker

SPOONUMBER

string(120)

Spool number including spool prefix

SPOW

element

Reference of SPEC owning SPCO of branch members

SPPOSN

integer

Position number of spigot plate

SPPURP

word

Special purpose table attribute

SPRA

real

word

Spec angle answer

SPRB

real

word

Spec bore answer

SPRE

element

Component spec reference

SPSF

element

Sheet pointset reference

SPSP

string(2)

Old spooler spool prefix

SPTYPE

word

Type of element to be selected

SPWD

string

word

Spec text answer

SQCURR

integer

Current value in sequence

SQMAX

integer

Maximum value of sequence

SQNAME

string(50)

Name of sequence

SQSTEP

integer

Increments in sequence

SQWRAP

logical

True if wrap around in sequence is allowed

SREF

string(12)

Source reference

SREL

integer

Start releases (packed)

SREVAY

element(50)

Sheet revisions array

SRFTRE

element

Reference to a SRFTRT element

SRTP

integer

Sorting priority for dimensions

SSLENGTH

real

Second side length

SSPLIT

logical

Spool Split

STACOM

string(1000)

Comment to the current status set

STAELE

real

Start Elevation

STAN

real

Start angle

STAP

real

Length of arrive straight tube

STAPOINT

integer

Cable Start connection point

STAREF

element

Cable Start reference

STASUS

logical

Current status suspended

STCD

string(100)

Symbol Code

STDEFREF

element

Status definition

STEREF

element(500)

Stencil reference array for schematic elements

STEX

string(120)

S Text string

STFC

real

Constant stretch factor

STFP

real

Proportional stretch factor

STINCD

string(120)

Inside surface treatment symbol code

STINRF

element

Inside surface treatment reference

STITL

string(120)

Sheet title

STLE

real

Length of leave straight tube

STLPOS

element

Status Element reference

STLR

element

Steel Reference

STLSF

element

Database reference

STMF

element

Template selection pointer

STOCKL

real

Stock Length

STOUCD

string(120)

Outside Surface treatment symbol code

STOURF

element

Outside surface treatment reference

STPDBS

element(5000)

Stamps containing db

STPSES

integer(2000)

Sessions used in at least one stamp

STPUV

pos

Start point

STRCON

string(120)

Stair Configuration

STRE

real

Spot value of stress

STREAT

string(26)

Surface treatment

STREV

string(120)

String value evaluation

STRSTD

string(120)

Stair Standard

STRXP

integer(500)

String expression

STRXPL

logical

True if surface treatment explicitly defined

STSESS

integer

Database session number

STSP

element

Structural specification

STVASD

element(500)

Status types eligible

STVCOM

string

element

Status comment

STVDEMOTE

element

Demote Status Value

STVDSC

string

element

Status description

STVHCO

string

element

Status held comment

STVHOL

logical

element

Current status held

STVLNK

element

element

Status value Reference

STVLSK

element(500)

Status Link Elements

STVLST

element(500)

Statuses assigned

STVNAM

string

element

Status value name

STVNUM

integer

element

Status value

STVPROMOTE

element

Promote Status Value

STVREF

element

Value Ref

STVSUS

logical

element

Current status held

STVTRV

element(500)

Valid Transitions

STVUNR

element(500)

Unresolved Status refs

STVUSD

element(10000)

Elements having this status value

STVVAL

element

element

Status value Reference

STYF

element

Rep style reference

STYP

string

SPECON type question

STYPDB

string

DB sub type

SUFFIX

string(120)

Suffix

SUPP

string(120)

Supplier Name

SUPR

element

SUPREF

SURF

string(120)

Surface Preparation

SURMAT

string(100)

Surface Material

SURNOR

dir

pos, dir

Surface Normal

SURPNT

pos

pos, dir

Surface Point

SURPRE

string(100)

Surface Preparation

SVASPLANE

logical

Hull symbolic view as plane Y/N

SVASSEMBLIES

element(100)

Hull symbolic view assembly elements

SVAUTO

logical

Hull symbolic view auto Y/N

SVBLEXCLUDE

logical

Hull symbolic view exclude blocks Y/N

SVBLOCKS

element(100)

Hull symbolic view block elements

SVCAX

logical

Hull symbolic view coord axis Y/N

SVCOMNO

integer

Hull symbolic view component number

SVCOMTYPE

integer

Hull symbolic view component type

SVCROSSSYM

logical

Hull symbolic view cross sect symbol Y/N

SVCURTYPE

integer

Hull symbolic view curve type

SVCURVES

element(100)

Hull symbolic view curve elements

SVDBEFORE

string(20)

Hull symbolic view depth before

SVDBEHIND

string(20)

Hull symbolic view depth behind

SVDRACCOM

logical

Hull symbolic view draw accommodation Y/N

SVDRAINTERS

logical

Hull symbolic view draw inters Y/N

SVDRAP

logical

Hull symbolic view draw plane V

SVDRCWAY

logical

Hull symbolic view draw cableway Y/N

SVDREQUIP

logical

Hull symbolic view draw equip Y/N

SVDRPIPE

logical

Hull symbolic view draw pipe Y/N

SVDRPVOL

logical

Hull symbolic view draw pvol Y/N

SVDRSTRUCT

logical

Hull symbolic view draw structure Y/N

SVDRVENT

logical

Hull symbolic view draw ventilation Y/N

SVLOOKING

integer

Hull symbolic view looking direction

SVLXMAX

string(20)

Hull symbolic view xmax

SVLXMIN

string(20)

Hull symbolic view xmin

SVLYMAX

string(20)

Hull symbolic view ymax

SVLYMIN

string(20)

Hull symbolic view ymin

SVLZMAX

string(20)

Hull symbolic view zmax

SVLZMIN

string(20)

Hull symbolic view zmin

SVNAME

string(1000)

Hull symbolic view name

SVPANELS

element(100)

Hull symbolic view panel elements

SVPLEXCLUDE

logical

Hull symbolic view exclude panels Y/N

SVPLTYPE

integer

Hull symbolic view plane type

SVPLXORIGIN

string(20)

Hull symbolic view x1

SVPLXUAXIS

string(20)

Hull symbolic view x2

SVPLXVAXIS

string(20)

Hull symbolic view x3

SVPLYORIGIN

string(20)

Hull symbolic view y1

SVPLYUAXIS

string(20)

Hull symbolic view y2

SVPLYVAXIS

string(20)

Hull symbolic view y3

SVPLZORIGIN

string(20)

Hull symbolic view z1

SVPLZUAXIS

string(20)

Hull symbolic view z2

SVPLZVAXIS

string(20)

Hull symbolic view z3

SVPNAM

string(1000)

Hull symbolic view pan name

SVPONLY

logical

Hull symbolic view pan only

SVPOSCOAXIS

string(20)

Hull symbolic view coord axis pos

SVREFLECT

logical

Hull symbolic view reflect Y/N

SVRSO

logical

Hull symbolic view RSO Y/N

SVSCALE

real

Hull symbolic view scale

SVSHPROFILE

logical

Hull symbolic view profile Y/N

SVSHSEAM

logical

Hull symbolic view shell seam Y/N

SVSHTHICK

logical

Hull symbolic view shell thickness Y/N

SVTYPE

integer

Hull symbolic view type

SVWAY

element(50)

Sheet Views array

SWING

word

Swing

SYLBTA

word

SYLBTAble attribute

SYMBFG

logical

Symbol flag

SYMELE

element

Reference to element on other side of CL (unset for non-symmetric)

SYMGRO

string(120)

Symbol Group

SYMLNS

integer

Side of direction vector

SYMM

integer

Symmetry code

SYMNAM

string(120)

Symbol Name

SYMXYZ

dir

Vector along symmetry line

SYSZ

real

Symbol size (uniform scaling)

SYTBOK

logical

SYLBTA attribute updated flag

SZDI

real

Start load point in section

TABANS

real(10)

Tabular answers

TAGCD

integer

Tag code

TAGCDS

integer(25)

Tag codes

TAGNMS

integer(25)

Tag numbers

TAGNUM

integer

Tag number

TANGLE

real

Tile Angle

TANGOF

real

Tangent offset

TANS

string(1024)

Text answer for text styp in spec

TARF

element

Target reference

TATYPE

string(10)

Text answer type

TBID

integer

Tribon ID

TBNAME

string(25)

TbName

TBOR

real

Tail bore

TCAT

element

Trace catalogue reference

TCDD

string(250)

word

Current design property default value

TCDP

string(250)

word

Current design property value

TCOD

string

Hashed origin code

TCON

word

Tail connection type

TCORRO

real

Tail Corrosion

TCREF

element(10)

Tail connections

TCTL

real

True cut length

TDEF

string(1024)

Text default for text styp in spec

TDET

element

Trace detail text reference

TDIR

dir

Tail direction

TDMF

element(2)

ISODRAFT Reference Dimension attribute

TDMT

word(2)

ISODRAFT Reference Dimension attribute

TDPR

real

word

Template design dataset property

TDRT

string(2000)

Trace detail RTEXT

TDST

string(2000)

Trace detail STEXT

TDTT

string(2000)

Trace detail TTEXT

TEAMLS

element(1000)

List of TEAMs to which USER belongs

TEASTA

word

Access Control team status

TEMF

element

Team reference

TEMP

real

Temperature

TEND

string

Connection at other end of TREF (HEAD or TAIL)

TEQDES

string(120)

To Equipment Description

TESTEV

logical

Result of constraint test evaluation

TESTXP

integer(500)

Logical Expression

TEXIST

logical

True if component has TUBI. Always true for offline bends.

TFDP

element

word

Template design dataset property

TGEOM

logical

True if component has TUBI geometry

TGRA

real

Pipework temperature gradient

THERMA

string(104)

Thermal category

THICKNESS

real

Thickness

THPO

pos

Point through which viewing

TIERHE

real(15)

Heights of trays measured from path

TIMEEND

integer

End time of COMMS window

TIMEINTERVAL

integer

COMMS retry time interval

TIMEOUTNUMBER

integer

COMMS max retry count

TIMER

string(120)

Frequency of DB propagation

TIMESTART

integer

Start time of COMMS window

TIMFAC

real

Pathtime time factor

TIMPET

string(15)

Time factor pre text

TIMPOT

string(15)

Time factor post text

TITL

string(1000)

Title

TLCONN

element(500)

List of elements connected to branch tail

TLIN

logical

True length indicator

TLREF

element(500)

List of attachment connected to attachment

TMAT

element

Trace material text reference

TMAV

real

Average temperature

TMDWG

string(120)

AutoCAD template name

TMMA

real

Maximum temperature

TMMI

real

Minimum temperature

TMPR

element

Template reference from SPCO

TMRF

element

Template reference

TMRMASTER

element

Template Repeat Master Duplicate Element

TMROWNER

element

Template Repeat Owning Element

TMRREF

element

Template Repeat Element Reference

TMRRULE

integer(500)

Template Repeat Rule

TMRXREF

element(500)

Return reference from TMRREL element to repeat elements

TMXT

string(2000)

Trace material XTEXT

TMYT

string(2000)

Trace material YTEXT

TMZT

string(2000)

Trace material ZTEXT

TOFFT

real

Tail offset

TOPOLOGY

string(120)

Branch topology

TOTALT

real

Total machine time for a nested plate

TOTLAB

real

Total label pathtime

TOTLEN

real

Total manual length

TOTT

real(2)

Total pathtime

TOTTI

real(2)

Total pathtime, I-bevel

TOTTX

real(2)

Total pathtime, X-bevel

TOTTY

real(2)

Total pathtime, Y-bevel

TPAR

real(30)

Trace catalogue component parameters

TPEN

integer

Text pen

TPLFRR

element(10000)

Topology references

TPON

integer

TO port number

TPOS

pos

Tail position

TPOSE

real

Easting of tail position

TPOSN

real

Northing of tail position

TPOSU

real

Upping of tail position

TPREF

element

Tail point reference

TPRESS

real

TestPressure

TPVAL

string(1000)

Task parameter name

TQUAL

string(1024)

Text qualifier in spec or sele

TQUES

string(1024)

Text question in spec or sele

TRANS

real(12)

Local transformation matrix

TRAYH

real

Tray height

TRAYOW

real

Tray other width

TRAYRW

real

Tray Reduce Width

TRAYSW

real

Tray side width

TRAYW

real

Tray Width

TRCG

logical

DRAFT user defined symbol trace flag

TRCLIN

word

Trace line

TREATP

element

Tread type

TREDOV

real

Tread Overlap

TREF

element

Tail reference

TRGENA

logical

Initial Value

TRIMCE

integer(10000)

Array of Trimmed Cells

TRIMTY

word

CTWALL TRIM TYPE

TRSF

element

Tag ruleset reference

TRUN

real

Truncation value (+ve) or percentage (-ve)

TSFBR

logical

Spooling marker for leave tube

TSIZ

real

Terminator size

TSLEN

real

Total suspension length

TSPE

element

Tracing spec reference

TSPR

element

Trace specification component reference

TTEX

string(2000)

T Text string

TTFACE

string(32)

TrueType font face name

TTFDES

string(128)

TrueType font description

TTFENA

logical

TrueType fonts enabled flag

TTFIND

integer

TrueType font index

TTYP

word

Template type

TUCL

real

Tube centreline length of branch

TUFG

logical

Tubing flag

TUFL

logical

Tube flag

TULE

real

Tube length of branch

TVIS

logical

Top visibility flag

TWALLT

real

Tail wall thickness

TWIDTH

real

Tread Width

TWIST

logical

True if twisted

TWLEN

real

Total weld length

TWRF

element

Tail Working Point (Router)

TWSTAN

real

Twist angle

TXALIGN

string

Text alignment

TXAREA

real

Total Cableway X-area

TXCOLO

integer

Text colour

TXCONU

integer

Text colour number

TXSPLI

logical

Text splitting flag

TXSTRI

string(1000)

Text String for enhanced LineStyles

TYNU

integer

Number type

TYPE

word

Type of the element, ignoring UDET, truncated to 4 or 6 characters

TYPEA

string(10)

TYPEA

TYPEB

string(10)

TYPEB

TYPECD

integer

Type code

TYPECE

integer

Type code

TYPEDB

string(6)

DB type

TYPEXPRESSION

string(4000)

Type Expression

TYPEXTYPE

string(60)

Type expression type

TYPINC

logical

Type is inclusive

TYSEQU

integer

Type Sequence Number

U

real

Position upping

UAEXSS

real

User Excess Arrive

UALL

logical

UALL

UAREA

real

Used area

UBULG

real

Used bulge factor for curve geometry

UCAT

string(50)

Category on forms

UCOD

integer

Units code

UCODB

integer

Units code bore

UCODD

integer

Units code distance

UCONN

logical

True if the UDA value should appear on the reference list form

UCURTYP

word

Used curve type

UCUTDI

dir

Upper Extension Cutting Direction

UDACPY

element

UDA copy

UDALIS

word(2000)

List of UDAs

UDASET

word(2000)

List of UDAs set

UDATLS

word(200)

List of attributes for UDET

UDETCHECK

string(120)

Report from UDET check on element

UDHLIST

word(200)

Attributes hidden on elements of this user-defined element type

UDIRECTION

dir

Up axis direction

UDMLIST

word(200)

List of allowed member types

UDNA

string(50)

User defined name

UDOLIST

word(200)

List of allowed owner types

UDPEND

word(200)

list of attributes that this attribute depends on

UEEXSS

real

User End Excess

UEXTNS

real

Upper Extension Length

UGOING

real(10)

Upper Tread Going

UHIDE

logical

Set true to hide attribute on forms

UHYPER

logical

Set true to treat attribute value as a named link to an external resource

UIWE

string(1000)

Unit insulation weight

UKEY

integer

UDA key - internal unique system identifier

ULEN

integer

Length of data or text

ULVOPT

logical

Determines if UDA valid values or range limit is optional

UMAX

real

Maximum value

UMIN

real

Minimum value

UNAM

string(12)

Name of user

UNDERL

logical

Underling flag

UPDCB

string(500)

ADP update callback

UPLLEN

real

Used raw plate length

UPPING

pos

Upping part expressed as a position

UPPREF

element

References to upper exit level

UPRLEN

real

Raw profile used length

UPROTE

logical

Set true to disallow viewing the attribute in a protected database

UPSEUD

logical

Set true to calculate attribute value rather than store it in a database. User code must be provided

URADI

real

Used radius for curve geometry

UREF

element

Units reference

URISE

real(10)

Upper Tread Rise

URL

string(1024)

URL

USCCOG

pos

User derived centre of gravity position

USCLHI

element(5000)

Elements in descendant hierarchy claimed to this user

USCWCO

pos

User derived wet centre of gravity position

USCWEI

real

Derived value for user weight

USCWWE

real

Derived value for user wet weight

USEF

element

User reference

USERC

string(120)

User name of user claiming element

USERLS

element(1000)

List of USERs belonging to TEAM

USERM

string(120)

attr

User making last modification

USESS

string(120)

integer

User creating session

USNCLH

element(5000)

Elements in descendant hierarchy not claimed to this user

USRCOG

integer(500)

User centre of gravity position

USRLI

element(50)

Valid users for given user login

USRWCO

integer(500)

User wet centre of gravity position

USRWEI

integer(500)

User entered weight value

USRWWE

integer(500)

User entered wet weight value

USYSTY

word

Name of the system attribute

UTEAMS

element(200)

Teams that will see a hidden attribute

UTYP

word

Type of attribute value

UUID

string(36)

Universally unique identifier

UUIDAR

integer(4)

Universally unique identifier, stored array

UUIDREF

element(500)

word

Universally unique identifier references

UUNI

string(20)

Units of attribute values (bore/distance/text)

UVVAL

string(500)

Valid value for UDA

UWEI

string(1000)

Unit pipe weight

UWGHT

real

Used weight

UWIDTH

real

Used width

UWMTXT

string(120)

User weight Manager text

UWP

pos

Upper Working Point

VALARR

element(50)

Valid Status Values

VALIDV

string(1000)

Valid value expression for VVALUE elements

VALNAM

string(50)

Local Name of a Status Value

VALNUM

integer

Numerical representation of a Status Value

VALREF

element

Status Value reference

VALRUL

string(1000)

Valid rule expression to test VALIDV attributes of VVALUE elements

VALTEX

string(120)

Textual representation of a Status Value

VANGLE

real

Angle from vertical

VBEVEL

logical

True if part has bevel type V

VCOMPD

string(50)

View Comparison Date

VCOMPS

element

View Comparison Stamp

VDISTA

real

Vertical Distance

VDPOS

pos

Dimension line/arc position

VDTINT

integer(2)

Verification date

VDTTXT

string(22)

Verification date text

VENID

string(120)

LMI Vendor ID

VERTDI

logical

VERTDI (true if Z axe is vertical )

VGAP

real

View gap length

VHEIGHT

real

Volume height

VIRF

logical

Virtual Flag

VISF

string(73)

Visio filename

VLIM

real(6)

View limits

VMAR

real

ADP view margins

VMCIAR

integer(10)

VM Component Int Array

VMCRAR

real(10)

VM Component Real Array

VMDRPDMS

logical

VM Draw anno using pdms engine Y/N

VMFCFB

logical

VM Fill Colour From Border Y/N

VMFLAY

integer

VM Fillstyle Layer

VMGLAY

integer

VM Geometry Layer

VMTASP

real

VM text aspect

VMTSLA

real

VM text slant (degrees)

VMUSYS

integer

VM Fillstyle Unit System

VNREF

element

VNOTE reference - special attribute for use by ADP

VOLTAC

string(1000)

Voltage AC

VOLTDC

string(1000)

Voltage DC

VRADI

real

Cableway radius

VRAT

real(2)

View ratio

VREG

real(4)

View region

VSCA

real

Viewing scale - scales projected view

VSHAPE

integer

Volume shape

VTITL

string(120)

View title

VTYP

string

Type of design view

VVOL

real(6)

View volume

VWIDT

real

Volume width

VWLIMI

real(6)

View Limits - special attribute for use by ADP

VWREFA

element(20)

View reference array - special attribute for use by ADP

VXREF

element(500)

Vertex reference array

W

real

Position westing

WALLTH

real

Tube wall thickness

WAMA

real

Maximum water level

WANS

word(100)

Word answers

WATERT

logical

Water Tight

WATTIM

real

Water cleaning time

WBORE

real

Bore on IWELD/RWELD

WCANG

real

Weld connection angle

WCOM

string(26)

Weld comment

WDBNA

string

Working DB name

WDESP

word(100)

Design parameters as words

WDIA

string(1000)

Wind diameter modulus

WEFA

real

Weight multiplier

WEIG

real(3)

Weighting value

WELDDP

real

Welding depth

WELDMC

element

Welding Machine Reference

WESUSP

real

Weld end suspension

WHOLEC

real

Array of Whole Cells

WIANG

real

Weld inclination angle

WIDARR

real(10)

Width array

WIDT

real

Width

WIFA

real

Wind multiplier

WJPOS

pos

Implied weld position

WJUSL

word

Wall Justification Line

WLDC

integer

Weld Code

WLDN

integer

Weld number

WLDP

string(4)

Weld number prefix

WLDPOS

string(26)

Welding position

WLDREF

element

integer

Return reference from Ppoint or WELD to IWELD or RWELD element

WLEGL

real

Weld leg length

WLEN

real

Weld length

WMAX

integer

Maximum weld number in current spool drawing

WNAM

string(26)

Weld name

WNLAY

integer

Number of weld layers

WORI

ori

World orientation

WORPOS

pos

World position

WPAR

word(100)

Parameters as a word

WPRE

real

Wind pressure

WPROC

string(26)

Welding process

WRANG

real

Weld rotation angle

WSHOP

logical

Weld shop/site flag on IWELD/RWELD

WSPEC

element

Weld specification on IWELD/RWELD

WSPROC

string(26)

Welding standard process

WSSUSP

real

Weld start suspension

WTCOM

string(300)

Weld table comment

WTEREF

element

integer

Wall thickness element reference

WTHICK

real

Wall thickness

WTHREF

element

Wall thickness table reference

WTOL

string(1000)

Wall thickness tolerance / Weight tolerance

WTORCH

dir

Weld torch vector

WTPROC

string(26)

Welding test procedure

WTRANS

real(12)

Transformation matrix to world

WTSTAT

string(26)

Weld table status

WVOL

real(6)

Enclosing box volume in world coordinates

XAMANG

real

Cross section along mounting angle

XAREA

string(1000)

Cross sectional area

XBEVEL

logical

True if part has bevel type X

XBOT

real

Bottom X length

XBSH

real

X bottom shear: inclination of bottom face to local X axis

XFTPT

pos

Cross section foot point

XINCL

real

Cross section inclination angle

XLEN

real

X length

XOFF

real

X-offset

XRLIST

element(10000)

elemtype

List distributed attributes

XRLSTT

word(2000)

elemtype

List distributed attributes

XRPNTR

element

Distributed Attributes reference

XRQCNT

integer

elemtype

Get distributed attributes element count

XRQELE

element

elemtype, integer

Get distributed attributes element

XRSTRT

element

Distributed Attributes reference

XTEX

string(2000)

X text

XTHK

real

Cross section thickness

XTOP

real

Top X length

XTPPT

pos

Cross section top point

XTRA

real

Extra length requirement for BOLTS

XTSH

real

X top shear: inclination of top face to local X axis

XXMANG

real

Cross section cross mounting angle

XXXDIR

dir

Direction Test attribute

XXXORI

ori

Orientation Test attribute

XXXPOS

pos

Position Test attribute

XYOFFS

real(2)

XY offset

XYPS

pos

2D Position

XYSC

real(2)

Label XY size

YBEVEL

logical

True if part has bevel type Y

YBOT

real

Bottom Y length

YBSH

real

Y bottom shear: inclination of bottom face to local Y axis

YDIR

dir

Preferred Y axis direction

YLEN

real

Y length

YOFF

real

Y-offset

YOUN

real

Spot value of Youngs modulus

YTEX

string(2000)

Y text

YTOP

real

Top Y length

YTSH

real

Y top shear: inclination of top face to local Y axis

ZDIR

dir

Additional axis direction

ZDIS

real

Position in section

ZLEN

real

Z length

ZOFF

real

Z-offset

ZTEX

string(2000)

Z text

TitleResults for “How to create a CRG?”Also Available in