Continuity Tab
- Last UpdatedMar 09, 2026
- 1 minute read
The Continuity tab is used to change or just view the patch continuity of a patch.
Use the Continuity tab
-
Select the patch to be changed in the Patch 1 list.
-
This causes the adjacent patches of the selected patch to be displayed in the Patch 2 list, along with their continuity type and direction.
-
Select the required patch from the Patch 2 list and select the Radio button for the type of continuity, either Tangent or Boundary.
-
Select the Continuity button to make the change.
The Patch 2 list will be updated to show the new continuity.
Note: It is only possible to change the type of continuity, not the direction. Therefore, if the user selects a patch in list Patch 2 where the direction is from and attempts to change the continuity, an error message will be displayed.