Transformation Components - Round to Flat Oval
- Last UpdatedJan 27, 2026
- 2 minute read
The task of creating an HVAC Component is initiated from the HVAC Window.
-
Select Transformations in the Categories dropdown list and then Round to Flat Oval in the Available Type dropdown list to display the Round > FlatOval window:

You are required to input the following dimensions:
-
Duct Diameter
-
Oval width LA
-
Oval depth LB
-
Length
-
A offset
-
B offset
-
Circ Extension
-
Oval Extension
-
Circ Male Collar
-
Oval Male Collar
-
-
To visualize how the dimensions equate to the actual piece of HVAC, select Picture to display a detailed drawing for Transformations Components Catalog Elements - Flatoval to Round.
Note: The fields will be pre-populated with default dimension. These dimension are governed by the details defined in the HVAC Catalog. The Circ and Oval Extension default is auto but can be changed to a required dimension.
-
Select Transpose width/depth to exchange Oval width LA dimension with Oval width LB dimension.
-
Specify a type of joint to use for the Circ Jnt (Circular Joint) and Oval Jnt (Oval Joint). For more information, refer to Create a Component.
-
After selecting the type of joint to use for the Circ Jnt and Oval Jnt, you must enter the Aoff Direction.
-
In Aoff Direction enter the direction for the Aoff Direction relative to the Point of Origin. Valid directions are E (East), N (North), U (Up), -E (negative East), -N (negative North) or -U (Negative Up). X, Y, Z, -X, -Y or -Z.
-
Using the Flip Circ/Oval dropdown list, choose whether to flip the direction of arrive and leave of the of the piece of HVAC, 180° relative to the point of origin.
-
In the Connect list, select Connect or Unchanged:
-
Select Connect (default when Create is selected) - connects the piece of HVAC to the previous one.
-
Select Unchanged (default when Modify is selected) - positions the piece of HVAC at the co-ordinates 0.00.
Note: Unchanged is usually used, when Modify is selected, it does not connect the piece of HVAC but positions it at 0.00, in effect in a floating position.
-
-
Select Defaults to reset all the fields back to when the Round > FlatOval window was opened.
-
Select Fit to orientate the Round > Flat Oval to automatically match the outlet (p-leave) of the previous piece of HVAC to the inlet (p-arrive) of the next piece.
-
Select OK to create the Round > Flat Oval component and close the Round > Flat Oval Window. You will be returned to the HVAC Window.
-
Select Cancel to discard all field changes and close the Round > Flat Oval window.