Modify PConns Form

  • Last UpdatedNov 17, 2025
  • 1 minute read

The Modify PConns form allows you to change the connection types on the Ppoints of elements with a given SKEY for one or more specifications.

Modify PConns

  1. Select Utilities, then select Pconns from the main window drop-down.

    The Modify PConns form opens:

  2. Select the specifications you wish to change in the SPEC Elements list.

  3. Enter the SKEY you wish to modify into the SKEY text box.

    1. Define the changes in the Modify Pconns From and To text boxes.

  4. To select the Pconns to modify, enter the Ctype for each Pconn in numerical order, separated by spaces, into the From text box.

    To change all the Pconns for an SKEY, enter * into the From box.

  5. The new Ctypes must be entered for each Pconn in numerical order, separated by spaces, into the To text box.

    Note: Text box entries are case sensitive.

  6. (Optional) Select Report changes to file to generate a report of the changes in the file specified in the File text box

    This report can also serve as a macro to reverse the changes if needed. To run the macro, enter $M <Path & Filename> in the Command Window.

  7. Click Apply.

    The changes are carried out and the details are shown in the Output list box.