Modify a Fitting
- Last UpdatedJan 28, 2026
- 2 minute read
To modify the definition of a fitting select Modify > Fitting > Definition from the main menu toolbar, the Modify Fitting window is displayed.

The procedure to modify the definition of a fitting is the same as for the creation of a Single Fitting, refer to Create Fittings.
Modify the position of the fitting
-
Make sure the section the fitting is attached to is the CE and select Modify > Fitting > Position Line.
The Position Line window is displayed but is greyed out and you are prompted to identify the fitting.
-
Click the fitting in the 3D graphical view.
The Position Line window becomes active.

-
Click Justification.
You are prompted to ‘Identify Pline to justify to:’
-
With the cursor in the 3D graphical view, identify the Pline to align the fitting to.
An aid arrow is displayed at the Pline location on the section, which points in the Z direction of the Pline. The aid arrow is identified by a text aid which shows the Pline name.

-
Click Apply to move the fitting to its new position.
Alternatively select the Pline location from the drop-down menu and click Apply.
-
When the new position has been established click Dismiss to discard any information and close the Position Line window.