Powering Calculation
- Last UpdatedAug 11, 2023
- 2 minute read
A standard powering calculation consists of the following calculations/output:
-
Condition independent input data (that means, unrelated to any particular condition), for example, main particulars data, appendage data and propeller parameters.
-
Optimum propeller data - results of the propeller design process, with a list of resulting parameters (for example, diameter, pitch ratio) followed by a table of
•
J
Advance Coefficient
•
KT
Thrust Coefficient
•
KQ
Torque Coefficient
•

Propeller efficiency
•


•
Speed Ratio

For each condition in turn:
-
Condition specific input data, for example, draught aft, draught fwd, resistance method chosen.
-
Table of ship scale resistance data - V, Fn, Rn, CF, CF x k, CR, Ca, CT and CircC.
-
Table of ship powering characteristics - V, PE, THDF, WFT,
,
, QPC, PS (or PD) and RPM.