Hull and Outfitting

Attributes of Isodraft Symbol Templates

  • Last UpdatedDec 19, 2025
  • 1 minute read

The attributes of Isodraft Symbol Templates that are additional to the attributes of normal symbol templates are as follows:

SKEY

Symbol key: the SKEY of the new Symbol. If this attribute is set to the SKEY of an existing symbol, the existing symbol will be redefined. You can use wildcards to define a symbol for several similar SKEYs, see Wildcards in SKEYs.

BKEY

Base symbol key. If a new SKEY is being defined, the BKEY must be set to a standard SKEY. Wildcards can be used, see Wildcards in SKEYs

SCALe value

Changes the size of the symbol without redefining the coordinates of the plotted shape (100 = full size).

SPINdle

Spindle symbol key. If this attribute is set, the Symbol Template will include a spindle symbol. for further information, see the Isodraft Reference Manual. Default NONE.

ORIN  NONE

Specifies a symmetrical fitting which the flow direction is not relevant

ORIN  FLOW

Specifies a fitting for which the flow direction is important, such as check valves

ORIN  REDUCER

Specifies a reducing fitting

ORIN  FLANGE

Specifies a fitting which begins with a flange; that is, one which is preceded by a gasket

FLWArrow  TRUE

Plots flow arrows on the symbol

FLWArrow  FALSE

Suppresses flow arrows

DIMEnsion  TRUE

Plots dimensions alongside the symbol. Default

DIMEnsion  FALSE

Suppresses the plotting of dimensions

INSL  TRUE

Insulation shown on symbol if specified. Default

INSL  FALSE

Insulation representation suppressed

TRCG  TRUE

Tracing shown on symbol if specified. Default

TRCG  FALSE

Tracing representation suppressed

FILL  TRUE

Symbol to be filled

FILL  FALSE

Symbol not filled. Default