Ignoring the DUNION attribute
- Last UpdatedNov 25, 2025
- 1 minute read
Use of the DUNION attribute on DESIGN elements such as FRMW, STRU, etc is described in the Design Reference Manual: Creating the Model, 'Section 5.14.2 Controlling Edge Representation in DRAFT'. The DUNION values are used during an UPDATE DESIGN process to determine whether common edges between FRMWs (say) should be drawn or omitted. However it is possible to ignore all DUNION values by setting the View's IGNDUN attribute (Ignore Dunion) to TRUE. (The default value is FALSE). After changing the IGNDUN attribute an UPDATE DESIGN will be required.