Specifying Minimum Lengths Irrespective of Bore
- Last UpdatedNov 14, 2025
- 1 minute read
Keywords:
TOLERANCE TUBE
Description:
The TUBE command, used alone, specifies the minimum acceptable tube length which is applicable to all tube diameters which have not been more specifically set.
|
Examples: |
|
|---|---|
|
TOL TUBE 100 |
Minimum acceptable length is 100 mm |
|
TOL TUBE DEFAULT |
Minimum acceptable length is 100 mm |
|
TOL TUBE 6 INCH |
Minimum acceptable length is 6 inches |
Command Syntax:
>-- TOLerance TUbe --+-- <uval> ---.
| |
‘-- DEfault --+-->
Querying:
>-- Query TUbe -->
>-- Query TOLerance OPTions -->
(also outputs ATTACHECK and misalignment settings; see Checking Parts of the Design and Piping/Hangers, respectively)