Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

Hull and Outfitting

Specifying Minimum Lengths Irrespective of Bore

  • Last UpdatedNov 14, 2025
  • 1 minute read

Keywords:

TOLERANCE TUBE

Description:

The TUBE command, used alone, specifies the minimum acceptable tube length which is applicable to all tube diameters which have not been more specifically set.

Examples:

TOL TUBE 100
(Default)

Minimum acceptable length is 100 mm

TOL TUBE DEFAULT

Minimum acceptable length is 100 mm

TOL TUBE 6 INCH

Minimum acceptable length is 6 inches

Command Syntax:

>-- TOLerance TUbe --+-- <uval> ---.
                     |             |
                     ‘-- DEfault --+-->

Querying:

>-- Query TUbe -->

>-- Query TOLerance OPTions -->

(also outputs ATTACHECK and misalignment settings; see Checking Parts of the Design and Piping/Hangers, respectively)