DIMDIST
- Last UpdatedAug 22, 2024
- 1 minute read
|
Function: |
Specifies distance between dimensioning lines and pipe/ component centrelines on the isometric plot (standout distance). Normally used to avoid overplotting lines on a complex isometric. |
|
Description: |
The default standout distances are: string dimensions 11mm; overall dimensions 16mm; support dimensions 6mm. Note: |
|
Examples: |
DIMDIST STRING 15 Sets standout distance for string/composite dimensions to 15mm. DIMDIST STRING 0.5 INCH Sets standout distance to 0.5 inch. DIMDIST SUPPORTS 10 Sets support dimensioning standout distance to 10mm. DIMDIST OVERALL 12 Sets overall dimensioning standout distance to 12mm |
|
Related Commands: |
DIMENSIONS SUPPORT SKEWBOX |
|
Command Syntax: |
>--- DIMDist ---+--- STRING* ----. where value is the standout distance. |
|
Querying: |
Q DIMDist |