Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

Hull and Outfitting

Attributes

  • Last UpdatedDec 13, 2023
  • 2 minute read

To control the dialog, picture attributes are added on view level. The following general attributes should be used:

Attribute

Variable

Value

9963

Endcut specific:

I1

Number of connection code restrictions.

S1-Sn

Connection code restrictions.

9962

I1

Number of default designations.

S1 - Sn

Default designation to be selectable within the dialog.

9961

I1

Order number when displayed in dialog.

I2

Meaning depending on dialog type:

Hole dialog:

0 - Standard hole.

1 - Penetration for a pipe or a ventilation duct.

2 - Penetration for a pillar.

3 - Hole from curve.

If the variable I2 does not exist then a standard hole is assumed.

Notch dialog:

0 - Standard notch.

1 - Notch from curve.

If the variable I2 does not exist then a standard notch is assumed.

Endcut dialog:

Endcut type.

S1 - S3

Text presented within the dialog. The text information can be used as documentation for the user.

9960

S1 - Sn

All views are by default displayed in all dialogs.

Using certain keywords, some views can be hidden when the dialog is used in certain applications or in a project. The following are valid keywords

General

PLPL (Planar Plate)

PLPR (Planar Profile)

SHPL (Shell Plate)

SHPR (Shell Profile)

STPL (Structure Plate)

STPR (Structure Profile)

NDIS (Not Displayed)

Bracket specific:

SYN1

SYN2

SYN3

SYN4

SYN5

SYN6

SYN7

SYN8

SYNV

Cutout Specific:

10

20

21

.

.

.

43

For the classification shapes in drawing __SBH_REST_PLATES__ the contents of this attribute is defined differently as specified below:

S1-Sn T

The names of classification shape arguments. Totally 7 can be defined. The exact number is defined by I2 below.

I1

Shape type

I2

Number of arguments

R1-Rh

Optional default values for each shape argument.

Endcut Specific:

S1 - Sn

Excluded profile types.

I1

Number of excluded profile types.

9959

S1 - Sn

Reference to a new drawing with the same layout (in case the user wants to customize dialogs in levels) or (in some cases) a reference to a Vitesse script. Strings are concatenated.

Only the drawings on the top level are having fixed names, defined by the system. Drawings on lower levels are named by the user, all referenced drawings must start with two underscores ("__")

9958

The presence of such an attribute (on the first view) indicates that no user input is needed. The name of the view shall be returned in dialogs.

The content of this attribute is irrelevant.

9957

The presence of such an attribute indicates that designations are possible to change by the user, that means, the profile dimensions may be changed by the user when selecting a new profile type and dimension.

Related Links
TitleResults for “How to create a CRG?”Also Available in