Combined Pipework Tolerance and Tube Length Options
- Last UpdatedNov 14, 2025
- 1 minute read
Keywords:
TOLERANCE OPTIONS DEFAULT
Description:
The OPTIONS command allows you to reset defaults for, or query, all data consistency checking options for Tubes at the same time.
|
Example: |
|
|---|---|
|
TOL OPTIONS DEFAULT |
Resets the following data-checking parameters:
|
Command Syntax:
>-- TOLerance OPTions DEFault -->
Querying:
>-- Query TOLerance OPTions -->
Outputs the current settings for all data checking parameters. The parameters are output in the current units.
Querying Examples:
With all default settings in force, the output resulting from a Q TOL OPT command will show one of the following sets of values (depending upon the current units):
MM Bores and Distances:
Minimum tube length : 100 mm
Tolerance Offset : 1 mm
Tolerance Angle : 0.0573
Tolerance Ratio : 0.001
Maximum Angle : 90
Atta checking : ON
INCH Bores and Distances:
Minimum tube length : 3.9 in
Tolerance Offset : 0 in
Tolerance Angle : 0.0573
Tolerance Ratio : 0.001
Maximum Angle : 90
Atta checking : ON
FINCH Bores and Distances:
Minimum tube length : 3.15/16
Tolerance Offset : 0.1/32
Tolerance Angle : 0.0573
Tolerance Ratio : 0.001
Maximum Angle : 90
Atta checking : ON