Procedure for Calibrating Holds
- Last UpdatedMay 24, 2023
- 1 minute read
-
Create a new node under the Ship node. Select Grain Calibrations from the dialog. A new folder node is created.
-
Edit this new node, and select the compartments that are used to carry grain.
-
Set up data that will be common to all holds, for example, coaming height, cargo heights, filled hold options, , and select OK. This will generate a calculation node for each grain compartment.
-
Edit each grain compartment node to change any data that is specific to the compartment.
-
Select any 'tween deck from the list. (Only decks that span the compartment, will be listed.)
-
Check that the sections are properly defined, by exporting them as a Britfair (bri) file, and viewing/editing them in Digit. When the sections are deemed to be OK, they can be read back into Calc from the same dialog page.
Important:
It is very important to have properly defined sections, otherwise the results will be inaccurate. -